
> Thin film deposition Model MFC2000 The products are designed for general-purpose, non-corrosive gas-flow control applications, with full-scale mass flow rates from 50 sccm to 200 SLPM. It features high accuracy and fast control time. Analog and RS485 Modbus interfaces are both offered. Other interfaces can also be requested. Flow direction Controller body Wire Color Definition 4 Yellow Setpoint, analog o - 5 Vdc 6 Gray Flow rate output, o - 5 Vdc 7 Brown Power supply, (12 - 24) Vdc, 1A Siargo Ltd. 4677 Old Ironsides Drive, Suite 310, Santa Clara, CA 95054 +1 (408) 969.0368 [email protected] www.Siargo.com
Open the catalog to page 1Siargo Product Datasheet Model: MFC2000 Mechanical dimensions Bio-reactors Carrier gas Thin film deposition Gas mixing Fermentation Fuel efficiency Leakage testers Packaging process Air quality Purging and venting Anesthesia gas Mechanical connections NPT VCR UNF Compressions Electrical interfaces Voltage 4~20 mA RS485 Modbus Other Bus interfaces 200 SLPM 4677 Old Ironsides Drive, Suite 310, Santa Clara, CA 95054 +1 (408) 969.0368 info@siargo
Open the catalog to page 2Siargo Product Datasheet Model: MFC2000 Specifications Value Full-scale range Repeatability Turn-down ratio Max control range Bio-reactors Carrier gas Thin film deposition Gas mixing Fermentation Fuel efficiency Leakage testers Packaging process Air quality Purging and venting Anesthesia gas 0 ~ 50 mLn/min … 0 ~ 5000 mLn/min 0 ~ 1 … 0 ~ 200 Ln/min ± 1.0% r.d. (20 ~ 100% of full scale) ±0.2% f.s. (<20% of full scale) Control pressure range Maximum operating differential pressure Setpoint source (input signal) Settling time (typical) Working temperature Humidity Burst pressure External leakage...
Open the catalog to page 3The product part number consists of the product model number and suffixes indicating the full-scale flow rate and other parameters. Referto the following for details. > Thin film deposition for other gases, please contact the manufacturer.) Default setpoint source (o - analog; 1 - digital) Setpoint source and output - Digital (B - RS485) and Analog (A - 4-20 mA; V - o - 5 Vdc). Selectable: BA or BV Mechanical connection, see Table 6.1. (For other connection (BSPT, etc.), please contact the manufacturer.) Maximum full-scale flow rate, see the table below. Maximum full-scale flow rate and mechanical...
Open the catalog to page 4Siargo Product Datasheet Model: MFC2000 Product selection and order Bio-reactors Carrier gas Thin film deposition Gas mixing Fermentation Fuel efficiency Leakage testers Packaging process Air quality Purging and venting Anesthesia gas 4677 Old Ironsides Drive, Suite 310, Santa Clara, CA 95054 +1 (408) 969.0368 info@siargo
Open the catalog to page 58 Pages
4 Pages
2 Pages
2 Pages
98 Pages
3 Pages
4 Pages
4 Pages
3 Pages
3 Pages
4 Pages
4 Pages
3 Pages
3 Pages
2 Pages
2 Pages
3 Pages
4 Pages
4 Pages
2 Pages
3 Pages