1. Catalogs
  2. Shimadzu France
  3. UV-2600i Plus /UV-2700i Plus

UV-2600i Plus /UV-2700i Plus
1 /20Pages

UV-2600i Plus /UV-2700i Plus

UV-2600i Plus /UV-2700i Plus
1 /20Pages

Catalog excerpts

UV-2600i Plus /UV-2700i Plus-1

UV-Vis Spectrophotometers

 Open the catalog to page 1
UV-2600i Plus /UV-2700i Plus-2

Perfect for a Wide Variety of Applications By accommodating a wealth of accessories, the system can address any user’s applications and a variety of situations. Measures Slight Differences in Absorbance Scalability to near-infrared measurement. Ultra-low stray light enables measurements down to absorbance values of 8 Abs. Enables Compliance with ER/ES Regulations and Stronger Data Management Configurable as a system for preventing data tampering. Efficiently prevents data tampering from entire series of analytical process steps. Spectral evaluation function enables unique pass/fail judgment for...

 Open the catalog to page 2
UV-2600i Plus /UV-2700i Plus-3

D o n ’t Mis s Any Pie ce o f th e P uzzle Single monochromator UV-2600i Plus Double monochromator UV-2700i Plus

 Open the catalog to page 3
UV-2600i Plus /UV-2700i Plus-4

High-level absorbance measurements for polarization films Absolute reflectance measurements for anti-reflective films Transmittance measurements for functional films Transmittance measurements for solar cell cover glass Band gap measurements and diffuse reflectance measurements for semiconductor materials Absolute reflectance measurements for highly reflective mirrors Transmittance and reflectance measurements for various types of films Thin film thickness measurements Plastic transmittance measurements, reflectance measurements, color measurements, and Hazen color Raw material confirmation tests...

 Open the catalog to page 4
UV-2600i Plus /UV-2700i Plus-5

Evaluating Thermal Stability (Tm) Analysis of Oligonucleotide Therapeutics Oligonucleotide therapeutics samples (9 to 60 pM) were analyzed using TMSPC™-8ip and 1 mm optical path length cells. Since UV-2600i Plus/2700i Plus can measure over a wide dynamic range, it is possible to perform a thermal stability analysis of nucleic acid drugs by obtaining the Tm value from the melting curve. Two types of window glass were measured utilizing the ISR-2600Plus integrating sphere. The sample shown by the red line is highly transparent to near-infrared light at 800 nm or more. The sample shown by the blue...

 Open the catalog to page 5
UV-2600i Plus /UV-2700i Plus-6

Single monochromator UV-2600i Plus Scalability to near-infrared measurement A key feature of the UV-2600i Plus equipped with a single monochromator is its measurement wavelength range. By using the optional ISR-2600Plus Integrating Sphere attachment, the measurement wavelength range can be extended from 220 nm to 1400 nm, significantly expanding its applications. Integrating Sphere Enables Measurements to 1400 nm Wider Measurement Wavelength Range The UV-2600i Plus is equipped with Shimadzu’s proprietary LO-RAY-LIGH™ grade diffraction grating, which achieves high efficiency and low stray light...

 Open the catalog to page 6
UV-2600i Plus /UV-2700i Plus-7

Transmittance/Reflectance Measurements of Multilayer Dielectric Film While Varying Angle of Incidence Using Variable Angle Measurement Unit for MPC-2600A Incident angle Black: 0° Red: 5° Blue: 12° Green: 30° Violet: 45° Variable Angle Measurement Unit Incident angle Red: 5° Blue: 12° Green: 30° Violet: 45° These measurement results from a multilayer dielectric film show the transmittance on the left and reflectance on the right. The results confirm that varying the incident angle changes the center wavelength of transmitted and reflected lig

 Open the catalog to page 7
UV-2600i Plus /UV-2700i Plus-8

LO-RAY-LIGH™ grade diffraction grating Achieves Ultra-Low Stray Light, Enabling 8 Abs Measurements Absorbance Linearity Calibration Curve In the case of a device equipped with a general double monochro- mator, the absorbance that can be covered is about 5 to 6, but the UV-2700i Plus offers a range to 8 Abs, with a transmittance value of 0.000001 % (1 part in 100 million). This system achieves high-level absorbance measurements with incomparable precision. In addition to measuring even high-concentration samples as is, eliminating the This shows the relationship between the absorbance and the...

 Open the catalog to page 8
UV-2600i Plus /UV-2700i Plus-9

Double monochromator UV-2700i Plus Measures Slight Differences in Absorbance Equipped with a double monochromator that achieves ultra-low stray light levels, the UV-2700i Plus is optimal for measuring low transmittance samples, such as polarization films used for LCD panels. The UV-2700i Plus is capable of 8 Abs measurements, and can make accurate transmittance measurements to 1 part in 100 million, accommodating a variety of sample measurements. Example of Polarization Film Measurement 6.000 With the rotating film holder (image below), two film samples can be set on the same optical axis. In...

 Open the catalog to page 9
UV-2600i Plus /UV-2700i Plus-10

LabSolutions™ UV-Vis Software Enables higher productivity and provides for a more convenient analytical environment. Different measurement applications can be started from the application launcher. Extensive UV validation software programs supporting instrument performance checks as well as optional software programs for special analyses are also available, so various measurements can be intuitively performed. Setting Parameters Instrument Control Panel Instrument parameter settings can be specified via panels that are separate from the measurement window. The control panels include various functionality...

 Open the catalog to page 10
UV-2600i Plus /UV-2700i Plus-11

From Measurement Improved Productivity of Data Analysis Operations to Data Output Data analysis and data output operations can be performed at the same time as data measure ment. Time spent outputting or analyzing data can also be reduced by simultaneously sending data to an Excel® spreadsheet in real time or saving data as text. The software can also automatically perform postprocessing of measured data, such as processing/correcting spectra, and perform pass/fail judgments of measurement results (automatic spectral evaluation). Automatic Spectral Evaluation (Spectral Evaluation Function) By...

 Open the catalog to page 11
UV-2600i Plus /UV-2700i Plus-12

Stronger Data Management Comprehensive Data Integrity Compliance In addition to LabSolutions UV-Vis, which provides basic functionality, Shimadzu offers LabSolutions DB UV-Vis and LabSolutions CS UV-Vis to meet the requirements of ER/ES regulations. LabSolutions DB UV-Vis LabSolutions DB UV-Vis allows for secure data management by integrating a data management function with LabSolutions UV-Vis. Compliant with ER/ES regulations, the software is optimally configured for customers using a PC. It is recommended for facilities that do not require network connections and want to be ER/ES compliant....

 Open the catalog to page 12

All Shimadzu France catalogs and technical brochures

  1. LCMS-2050

    16  Pages

  2. MCT Series

    12  Pages

  3. LC/MS/MS

    2  Pages

  4. SALD-7500nano

    16  Pages

  5. LC/MS/MS MRM

    2  Pages

  6. LC/MS/MS

    2  Pages

  7. TRViewX

    8  Pages

  8. UW/UX Series

    4  Pages

  9. LCMS-8060

    20  Pages

  10. QC Reporter

    6  Pages

  11. OneSight

    4  Pages

  12. TD-30 Series

    12  Pages

  13. Nexis GC-2030

    20  Pages

  14. MOC63u

    6  Pages

  15. UHPLC Nexera X2

    20  Pages

  16. TOC-L

    16  Pages

  17. RF-6000

    24  Pages

  18. iMScope Trio

    28  Pages

  19. UV-3600 Plus

    26  Pages

  20. EDX-7000/8000

    24  Pages

  21. LCMS-IT-TOF

    16  Pages

  22. ELB SERIES

    2  Pages

  23. TW TWC SERIES

    8  Pages

*Prices are pre-tax. They exclude delivery charges and customs duties and do not include additional charges for installation or activation options. Prices are indicative only and may vary by country, with changes to the cost of raw materials and exchange rates.