TRViewX
1 /8Pages

TRViewX

TRViewX
1 /8Pages

Catalog excerpts

TRViewX-1

Non-Contact Digital Video Extensometer

 Open the catalog to page 1
TRViewX-2

The Shimadzu TRViewX not only far exceeds the measurement accuracy of conventional video type extensometers, but is also capable of width measurements. Furthermore, thanks to complete synchronization with TRAPEZIUMX testing machine software, the system provides the assist line functionality to simplify specimen mounting, specimen video recording, and other convenient (intelligent) functionality. Together with the adoption of a camera stand reflecting careful attention both to operability and design, this non-contact extensometer offers dramatically improved performance and ease of use. Since...

 Open the catalog to page 2
TRViewX-3

Select the Optimum Model to Suit Your Specimens Meeting demands with a wide lineup featuring cameras with different fields of view Single Camera Model TRViewXS Series 55 to 240 mm field of view: Examine a specific area in detail (ISO/JIS Class 0.5 compatible) Maximum of 800 mm field of view: Even large elongation specimens can be measured. The ultimate system, simultaneously attaining high accuracy and a wide field of view Double Camera Model TRViewXD Series Small displacements are measured with a high accuracy camera, achieving ISO/JIS Class 0.5. During testing, the camera can switch to large...

 Open the catalog to page 3
TRViewX-4

Complete Synchronization with TRAPEZIUM X-V / TRAPEZIUMX Simplifies Operability T h e c o m p l e t e s y n c h r o n i z a t i o n i s a c h i e v e d w i t h t h e p o p u l a r, e a s y - t o - o p e ra t e T R A P E Z I U M X - V / T R A P E Z I U M X s o f t w a re f o r t e s t i n g m a c h i n e s. Simply select the TRViewX testing conditions to automatically set the measurement mode. All operations from start to finish of the test can be controlled by the software. It is possible to measure the actual gauge length when testing starts. Operational guidance Straightforward operations with...

 Open the catalog to page 4
TRViewX-5

Video and Still Image Functionality Enables Detailed Analysis and Strain Distribution V ideo Recording, Playback Functionality and Still Image Functionality The testing conditions can be video recorded. A variety of playback functions from start to finish of testing, including replay only in the vicinity of fracture, pause function, and frame-by-frame playback. During playback, the display is synchronized with the graph. Select a point on the graph with the mouse (point picking) to display the image of that part. During testing, images of a particular part can be extracted, and output to reports...

 Open the catalog to page 5
TRViewX-6

Single Camera Model (TRViewXS Series) Select from five models differing in the size of the camera's field of view. This table is the example of the model selection F.O.V. requires (initialG.L + elongation) x 1.5 to 2.0. (Note 1) (PCIExpress x 4) slots are required for the PC. (Note 2) A suitable calibration bar is packaged with the lens used. * This software is incorporated in the TRAPEZIUMX testing machine control software. It does not exist as separate software. * A safety cover cannot be used with this instrument. The safety cover must be removed to use this instrument. Contact Shimadzu if...

 Open the catalog to page 6
TRViewX-7

(Note 1) The field of view and elongation measurement range differ The field of view indicates the image-taking range of the cameras. In general, a field of view of (initial GL + elongation) x 1.5 to 2 is required. In addition, the field of view differs with the camera's vertical position, and the testing machine's vertical and longitudinal dimensions. The field of view may become narrow particularly when using double camera models (TRViewXD Series). (Note 2) The accuracy is defined as the absolute error with respect to the indicated value, or the relative error with respect to the indicated...

 Open the catalog to page 7
TRViewX-8

(1) Sticker-Type Gauge Marker These sticker-type gauge markers are adhered to the test object. *Depending on the specimen material and display conditions, the gauge marker stickers may tend to come off at low temperatures. (2) Clip-Type Gauge Marker External Dimensions (example for mounting on testing machine) AGX-V floor type AGX-V table-top type thermostatic chamber SHIMADZU Shimadzu Corporation For Research Use Only. Not for use in diagnostic procedures. This publication may contain references to products that are not available in your country. Please contact us to check the availability of...

 Open the catalog to page 8

All Shimadzu France catalogs and technical brochures

  1. LCMS-2050

    16  Pages

  2. MCT Series

    12  Pages

  3. LC/MS/MS

    2  Pages

  4. SALD-7500nano

    16  Pages

  5. LC/MS/MS MRM

    2  Pages

  6. LC/MS/MS

    2  Pages

  7. UW/UX Series

    4  Pages

  8. LCMS-8060

    20  Pages

  9. QC Reporter

    6  Pages

  10. OneSight

    4  Pages

  11. TD-30 Series

    12  Pages

  12. Nexis GC-2030

    20  Pages

  13. MOC63u

    6  Pages

  14. UHPLC Nexera X2

    20  Pages

  15. TOC-L

    16  Pages

  16. RF-6000

    24  Pages

  17. iMScope Trio

    28  Pages

  18. UV-3600 Plus

    26  Pages

  19. EDX-7000/8000

    24  Pages

  20. LCMS-IT-TOF

    16  Pages

  21. ELB SERIES

    2  Pages

  22. TW TWC SERIES

    8  Pages

*Prices are pre-tax. They exclude delivery charges and customs duties and do not include additional charges for installation or activation options. Prices are indicative only and may vary by country, with changes to the cost of raw materials and exchange rates.