SPD-20A / SPD-20AV UV/VIS Detector

SPD-20A / SPD-20AV UV/VIS Detector

SPD-20A / SPD-20AV UV/VIS Detector

Product catalog summary
Overview: The SPD-20A and SPD-20AV are UV/VIS detectors designed by Shimadzu Europa GmbH. These detectors are equipped with different light sources and offer a range of features for precise wavelength detection and analysis.
Light Source: The SPD-20A uses a deuterium lamp, while the SPD-20AV includes a deuterium lamp, tungsten lamp, and mercury lamp for wavelength accuracy checks.
Wavelength Range: SPD-20A covers 190 – 700 nm, and SPD-20AV extends from 190 – 900 nm. Both models have automatic cut-off filters to eliminate second-order diffraction.
Performance Specifications:
  • Spectral Bandwidth: 8 nm
  • Wavelength Accuracy: ± 1 nm
  • Wavelength Reproducibility: ± 0.1 nm
  • Drift: 1x10-4 AU/h max under constant temperature
  • Noise Level: ± 0.25x10-5 AU max
Cell Specifications:
  • Path Length: 10 mm
  • Volume: 12 µL
  • Pressure Tolerance: 12 MPa
Temperature and Tubing: The cell temperature input range is 9 – 50°C, with SUS316L tubing dimensions of O.D. 0.8 mm x I.D. 0.25 mm.
Dual Wavelength Mode: Allows selection of two wavelengths within specified ranges, with a sampling frequency of 1.2 sec for one wavelength.
Response and Range: 11 selectable response steps, with a range of 0.0001 – 2.56 AUFS.
Additional Features:
  • Auto Zero Function: Includes baseline shift function and polarity switching.
  • Wavelength Scanning: Capable of scanning with flow stopped, with selectable steps and speeds.
  • Time Program: Available with up to 32 steps for various settings.
Output Options: Includes connectors for recorders and integrators, supporting various chromatogram outputs.
Physical and Power Specifications:
  • Lamp Hour Meter: Records up to 9999.9 hours
  • Wetted Surface Material: SUS316L, PFA, quartz
  • Operating Temperature Range: 4 - 35°C
  • Power Requirements: 100/120/220-230 V AC, 160 VA, 50/60 Hz
  • Dimensions: W 260 x H 140 x D 420 mm
  • Weight: 13 kg
See more

Catalog excerpts

SPD-20A / SPD-20AV UV/VIS Detector-1

Shimadzu Europa GmbH www.shimadzu.de Albert-Hahn-Str.6-10 47269 Duisburg Specification Sheet SPD-20A / SPD-20AV UV/VIS Detector SPD-20A SPD-20AV Deuterium lamp Deuterium lamp, tungsten lamp, Light source mercury lamp (for wavelength accuracy check) Wavelength range 190 – 700 nm Cut-off filter to eliminate second-order diffraction is automatically activated for 371 - 700 nm range 190 – 900 nm 190 – 370 nm (D2 lamp) 371 – 900 nm (W lamp) Cut-off filter to eliminate second-order diffraction is automatically activated for 701 - 900 nm range Spectral bandwidth 8 nm Wavelength accuracy ± 1 nm Wavelength reproducibility ± 0.1 nm *1 Drift 1x10-4 AU/h max. (250 nm, room temperature constant, air in cell) 3x10-4 AU/h max. (250 nm, room temperature fluctuation less than 2°C, air in cell) 1x10-4 AU/h max. (250 nm, 600 nm, room temperature constant, air in cell) 3x10-4 AU/h max. (250 nm, 600 nm, room temperature fluctuation less than 2°C, air in cell) Noise Level ± 0.25x10-5 AU max. (250 nm, air in the cell, equivalent to 2 sec time constant *2) ± 0.25x10-5 AU max. (250 nm, 600 nm, air in the cell, equivalent to 2 sec time constant *2) Cell path length 10 mm Cell volume 12 ìL Cell pressure tolerance 12 MPa *1 Reproducibility when the wavelength is changed after turning the power ON in single wavelength mode *2 In single wavelength mode

 Open the catalog to page 1
SPD-20A / SPD-20AV UV/VIS Detector-2

Shimadzu Europa GmbH www.shimadzu.de Albert-Hahn-Str.6-10 47269 Duisburg Specification Sheet: SPD-20A/AV UV/VIS Detector (2/3) Cell temperature input range 9 – 50°C, at 1°C steps Cell inlet, outlet tubing diameter SUS316L tubing O.D. 0.8 mm x I.D. 0.25 mm Selectable, two wavelengths in 190 - 370 nm or 371 - 700 nm range Selectable, two wavelengths in 190 - 370 nm, 371 - 700 nm or 701 - 900 nm range Dual wavelength mode Sampling frequency 1.2 sec for one wavelength Response 11 steps selectable (corresponding to time constant 0.02, 0.05, 0.1, 0.5, 1.0, 1.5, 2.0, 3.0, 6.0, 8.0, 10.0 sec) Range 0.0001...

 Open the catalog to page 2
SPD-20A / SPD-20AV UV/VIS Detector-3

Shimadzu Europa GmbH www.shimadzu.de Albert-Hahn-Str.6-10 47269 Duisburg Specification Sheet: SPD-20A/AV UV/VIS Detector (3/3) Lamp hour meter Record up to 9999.9 hours Wetted surface material SUS316L, PFA, quartz Operating temperature range 4 - 35°C Power requirements 100/120/220-230 V AC, 160 VA, 50/60 Hz Dimensions W 260 x H 140 x D 420 mm Weight: 13 kg

 Open the catalog to page 3

All Shimadzu France catalogs and technical brochures

  1. LCMS-2050

    16  Pages

  2. MCT Series

    12  Pages

  3. LC/MS/MS

    2  Pages

  4. SALD-7500nano

    16  Pages

  5. LC/MS/MS MRM

    2  Pages

  6. LC/MS/MS

    2  Pages

  7. TRViewX

    8  Pages

  8. UW/UX Series

    4  Pages

  9. LCMS-8060

    20  Pages

  10. QC Reporter

    6  Pages

  11. OneSight

    4  Pages

  12. TD-30 Series

    12  Pages

  13. Nexis GC-2030

    20  Pages

  14. MOC63u

    6  Pages

  15. UHPLC Nexera X2

    20  Pages

  16. TOC-L

    16  Pages

  17. RF-6000

    24  Pages

  18. iMScope Trio

    28  Pages

  19. UV-3600 Plus

    26  Pages

  20. EDX-7000/8000

    24  Pages

  21. LCMS-IT-TOF

    16  Pages

  22. ELB SERIES

    2  Pages

  23. TW TWC SERIES

    8  Pages

*Prices are pre-tax. They exclude delivery charges and customs duties and do not include additional charges for installation or activation options. Prices are indicative only and may vary by country, with changes to the cost of raw materials and exchange rates.