1. Catalogs
  2. Shimadzu France
  3. Shimadzu’s LC/GC Drivers for Waters ™ Empower ™

Shimadzu’s LC/GC Drivers for Waters ™ Empower ™

Shimadzu’s LC/GC Drivers for Waters   ™   Empower   ™

Shimadzu’s LC/GC Drivers for Waters ™ Empower ™

Product catalog summary
Newest Models Compatible with Empower
Updated drivers now allow Shimadzu's latest LC and GC systems, including the Nexera™ series and i-Series LC models, as well as the Nexis™ GC-2030, to be controlled by Empower software. This integration enables advanced HPLC operations such as mobile phase monitoring, dual-injection functionality, and autosampler pretreatment. GC users benefit from high resolution and shorter analysis cycles through advanced flow technology.

System Control and Monitoring
Shimadzu LC and GC system parameters can be configured via Empower's instrument method editor. The control panel offers functionalities for monitoring system status, checking consumable usage, and performing routine inspections, enhancing user confidence and operational efficiency.

Multi-Vendor Support
Shimadzu's LC/GC driver software supports multi-vendor environments, providing optimal conditions for operating LC and GC systems through Empower. This includes instrument control, sample and data analysis, and report generation.

Licensing and System Requirements
The product content includes various licenses for LC and GC control, with options for different numbers of licenses. A dedicated Shimadzu LAC/E32 acquisition server is necessary for Empower Enterprise systems, supporting up to four Shimadzu units per server, with limitations based on connected detectors.

Driver Compatibility
Drivers are available for a range of Shimadzu models, including the Nexera series, i-Series, and various GC models. Compatibility with these drivers ensures seamless integration with Empower software.

Disclaimer
This publication is intended for research use only and may reference products not available in all countries. Shimadzu disclaims any proprietary interest in third-party trademarks mentioned.
See more

Catalog excerpts

Shimadzu’s LC/GC Drivers for Waters   ™   Empower   ™-1

Experience New Benchmarks with Empower Shimadzu’s LC/GC Drivers for Waters™ Empower™ Shimadzu’s LC/GC driver software is designed for customers that are considering multi-vendor support for Empower software. It provides the optimal environment for operating LC and GC systems, including the latest by enabling instrument control, sample analysis, data analysis, report output, and other operations using Empower software. Nexera series Ultra High Performance Liquid Chromatograph Newest Models Compatible with Empower Updated drivers enable control of Shimadzu’s newest LC and GC systems, including the modular LC Nexera™ series models, i-Series integrated LC models, and the Nexis™ GC-2030, by Empower software. Consequently, Empower can be used to experience Shimadzu’s advanced HPLC operations, such as mobile phase monitoring, dual-injection functionality for simultaneously analyzing the same sample via two separate systems, and autosampler pretreatment functionality. GC users can achieve high resolution with advanced flow technology and shorter analysis cycles by overlapping actions. Shimadzu LC and GC system parameters can be set via the instrument method editor in Empower. As a result, users controlling Shimadzu LC or GC systems from Empower can use the driver with confidence. In addition to controlling the systems, the control panel in Empower includes functionality for monitoring system operating status at a glance, checking the usage frequency of consumables, and so on. That makes it easy to perform routine system inspection and conditioning steps prior to analysis and monitor Control Panel the operating status during analysis.

 Open the catalog to page 1
Shimadzu’s LC/GC Drivers for Waters   ™   Empower   ™-2

* A dedicated Shimadzu LAC/E32 acquisition server is required for Empower Enterprise systems. * Up to four Shimadzu LC or GC units can be controlled from a single computer or LAC/E32 acquisition server. However, if one or two PDA detectors are connected, then the number of LC units that can be connected is limited to three or two units. * In addition to the system controller license included with the LAC/E32 unit, a Shimadzu LC/GC controller license is also required in order to control Shimadzu LC/GC units. y List of Drivers LC Driver Main Unit Nexera, Nexis, Prominence and AOC are trademarks...

 Open the catalog to page 2

All Shimadzu France catalogs and technical brochures

  1. LCMS-2050

    16  Pages

  2. MCT Series

    12  Pages

  3. LC/MS/MS

    2  Pages

  4. SALD-7500nano

    16  Pages

  5. LC/MS/MS MRM

    2  Pages

  6. LC/MS/MS

    2  Pages

  7. TRViewX

    8  Pages

  8. UW/UX Series

    4  Pages

  9. LCMS-8060

    20  Pages

  10. QC Reporter

    6  Pages

  11. OneSight

    4  Pages

  12. TD-30 Series

    12  Pages

  13. Nexis GC-2030

    20  Pages

  14. MOC63u

    6  Pages

  15. UHPLC Nexera X2

    20  Pages

  16. TOC-L

    16  Pages

  17. RF-6000

    24  Pages

  18. iMScope Trio

    28  Pages

  19. UV-3600 Plus

    26  Pages

  20. EDX-7000/8000

    24  Pages

  21. LCMS-IT-TOF

    16  Pages

  22. ELB SERIES

    2  Pages

  23. TW TWC SERIES

    8  Pages

*Prices are pre-tax. They exclude delivery charges and customs duties and do not include additional charges for installation or activation options. Prices are indicative only and may vary by country, with changes to the cost of raw materials and exchange rates.