RF-6000

RF-6000
1 / 24 PagesView full catalog

RF-6000

Product catalog summary
Introduction
The RF-6000 Spectrofluorophotometer by Shimadzu Corporation is engineered for high sensitivity, stability, and speed in fluorescence measurements. It boasts a high signal-to-noise ratio (SNR), rapid scanning capabilities, and a long-life xenon lamp.

Specifications
The device features a signal-to-noise ratio of 1,000 or more (RMS) / 350 or more (P-P), a scanning speed of 60,000 nm/min, a lamp life of 2,000 hours, and a wavelength range up to 900 nm.

Usability
Equipped with LabSolutions RF software, the RF-6000 simplifies analysis with validation routines and status indicators, and includes a large sample compartment.

Spectral Techniques
The RF-6000 supports various spectral techniques such as fluorescence, bioluminescence, chemiluminescence, and electro-luminescence, allowing for high-speed 3D scanning and measurements of fluorescence quantum yield and efficiency.

Applications
The spectrofluorophotometer is applicable in fields like chemicals, pharmaceuticals, electronics, foods, life sciences, and environmental studies, analyzing substances from artificial photosynthesis mechanisms to low-level contaminants in rivers and soils.

Advanced Measurements
Capable of measuring long-wavelength fluorescence up to 900 nm, the RF-6000 is useful for researching photosynthetic proteins and supports 3D fluorescence measurements for mineral identification and DNA detection.

Synchronized Scan Mode
This mode uses both an excitation monochromator and a fluorescence monochromator offset by fixed wavelength intervals, enabling detection of sharp fluorescence peaks in complex mixtures.

Measurement of Chlorophyll
Chlorophyll content in water is measured using fluorescence, requiring high sensitivity due to low concentrations. Narrow bandwidths yield consistent spectra, enhancing measurement accuracy.

Instrument Features
The RF-6000 is equipped with a long-life xenon lamp and a high-sensitivity detector, capable of measuring fluorescence spectra from extremely dilute samples and supports high-speed scanning.

High Sensitivity and Stability
With a redesigned optical and signal processing system, the instrument achieves high sensitivity, allowing accurate measurements over a wide dynamic range, capable of measuring fluorescein concentrations as low as 1 × 10-13 mol/L.

Usability and Software
The LabSolutions RF software offers a consistent interface across all measurement programs, including tools for spectral correction, quantitative analysis, and real-time spectral correction functions.

Conclusion
The RF-6000 Spectrofluorophotometer combines advanced technology with user-friendly software to provide accurate and efficient measurements across a wide range of applications, making it suitable for various fields including environmental analysis.
See more

Catalog excerpts

RF-6000-2

St ri v i n g f or t he Ultima te in Acc ura cy and E as y O per ability By combining new technologies with those cultivated over Shimadzu's long history, the Shimadzu spectrofluorophotometer has been reborn as the RF-6000. Combined with new LabSolutions RF software, designed for unrivaled measurement accuracy and easy operation, the RF-6000 offers the ultimate performance for a diverse range of customers' measurement needs.

 Open the catalog to page 2
RF-6000-3

W i d e Variety of Spectral Techniques Enhanced sensitivity and dynamic range enable fluorescence as well as bioluminescence, chemiluminescence, and electro-luminescence measurements. High-speed 3D scanning enables rapid acquisition of 3D spectra. Spectral-Corrected Excitation and Emission spectra can be scanned. Fluorescence quantum yield and Fluorescence quantum efficiency measurements are available. H i g h S e nsitivity, High Stability and High Speed Highest level SNR in its class: 1,000 or more (RMS) /350 or more (P-P) High-speed scanning of 60,000 nm/min minimizes scan time. 2,000 hour...

 Open the catalog to page 3
RF-6000-4

W i d e Variety of Spectral Techniques Supports Applications in a Wide Variety of Fields Pharmaceuticals Analysis of components in compounds Identification of artificial photosynthesis mechanisms Quality control of API or drug products Life Sciences Spectral properties of fluorescence probes Analysis of coumarin in light diesel oil Foods Quantitative analysis of additives Quality control of packaging Electrical/Electronics Environmental Evaluation of low-level contaminants in rivers and soils Spectral properties of fluorescent materials Measurement of quantum efficiency and quantum yield Analysis...

 Open the catalog to page 4
RF-6000-5

Electrical/Electronics Evaluating the Luminous Efficiency of Solid-State Semiconductor Materials A 100 mm diameter Spectralon integrating sphere unit was used to measure the fluorescence quantum efficiency of the light-emitting layer of a solid-state semiconductor material (tris(8-hydroxyquinolinato)aluminum) used in an organic EL device. Using the quantum efficiency measurement application of LabSolutions RF software allows determining the fluorescence quantum efficiency easily using intuitive software commands. The integrating sphere unit fits completely inside the sample compartment, eliminating...

 Open the catalog to page 5
RF-6000-6

Chemicals Long Wavelength Measurements The standard configuration can measure fluorescent wavelengths up to 900 nm, which means it can be used to research photosynthetic proteins for determining the mechanisms involved in artificial photosynthesis. In this case, a Thylakoid membrene solution was measured.*1, 2 The fluorescence spectrum shows that the system can accurately measure the fluorescence peaks in the long wavelength region. A spectral correction function, allowing the accurate measurement of spectral shapes in real time, is also included standard. Fluorescence Intensity Fluorescence...

 Open the catalog to page 6
RF-6000-7

Chemicals Potential for Identifying the Source of Minerals Calcite is a clear and colorless mineral consisting primarily of lime rock. Any impurities in the calcite may cause coloration. This example shows 3D fluorescence measurement (Excitation vs Emission) data for three types of calcite. Calcite A and B are clear and yellow whereas calcite C is clear and pink. 3D fluorescence patterns of calcite A and B were the same. In contrast, on the 3D fluorescence patterns of calcite C, there was a fluorescence peak at about 370 nm (EX; about 205 nm) and a strong fluorescence at about 430 nm (EX; about...

 Open the catalog to page 7
RF-6000-8

Pharmaceuticals Measuring Duloxetine Hydrochloride (USP) Fluorescence Intensity Fluorescence Intensity Duloxetine hydrochloride is a compound used as an antidepressant. In this example, an RF-6000 was used to measure duloxetine hydrochloride. The results indicated a lower limit of quantitation of 0.0007 μg/mL and a lower limit of detection of 0.0002 μg/mL, showing the ability of the RF-6000 to measure very low concentrations. Concentration (μg/mL) Fluorescence Spectra of Duloxetine Hydrochloride Calibration Curve Life Sciences Fluorescent Dyes for DNA Detection Specified complementary DNA can...

 Open the catalog to page 8
RF-6000-9

Foods Classifying and Identifying Types of Milk There are many types of milk products, such as raw or processed and those classified by fat content levels (low-fat, non-fat, and so on). These different types of milk products can have different 3D fluorescence spectra. In this example, three different types of milk products (A, B, and C) were used to measure 3D fluorescence spectra while varying the excitation wavelength. Samples were diluted by five times with distilled water. The results show that milk samples A and C have different fluorescence patterns. However, milk sample B has a fluorescence...

 Open the catalog to page 9
RF-6000-10

Environmental Measuring Oil in Water - ASTM D5412 The American Society for Testing and Materials (ASTM) testing standard D 5412 specifies testing for polycyclic aromatic hydrocarbons contained in water as oil. In this example, the target substance was separated from a solution prepared with a mixture of five polycyclic aromatic hydrocarbons using synchronized scan*. Figure 1 is a fluorescence spectrum of the mixture of polycyclic aromatic hydrocarbones. Figure 2 is a synchronized scan spectrum of Benzo[a]pyrene. Figure 3 is a synchronized scan spectrum of the mixture. The fluorescence peak of...

 Open the catalog to page 10
RF-6000-11

Environmental Trace Measurement of Chlorophyll Fluorescence Intensity The chlorophyll content is commonly measured when inspecting the water quality of rivers and lakes. Since the concentration of chlorophyll is low in rivers and other such waters, high sensitivity is required for measurements. Chlorophyll emits fluorescent light when exposed to light, but the light exposure causes the fluorescence intensity to gradually diminish. Therefore, fluorescence measurements that apply only a slight amount of excitation light are required. If the same chlorophyll solution is measured repeatedly with...

 Open the catalog to page 11
RF-6000-12

H i g h S e nsitivity, High Stability and High Speed High-Sensitivity Measurements High-sensitivity measurements can be performed with S/N ratios of 1,000:1 (RMS) or 350:1 (P-P). Improved lower limit of quantitation. Measures concentrations up to 1 × 10-13 mol/L (fluorescein). A redesigned optical system and signal processing system achieve the highest S/N ratio levels in its class. Even extremely dilute samples can be measured accurately. The RF-6000 can measure fluorescence spectra from fluorescein concentrations as low as 1 × 10-13 mol/L. Furthermore, due to an auto-gain control function that...

 Open the catalog to page 12

All Shimadzu France catalogs and technical brochures

  1. LCMS-2050

    16  Pages

  2. MCT Series

    12  Pages

  3. LC/MS/MS

    2  Pages

  4. SALD-7500nano

    16  Pages

  5. LC/MS/MS MRM

    2  Pages

  6. LC/MS/MS

    2  Pages

  7. TRViewX

    8  Pages

  8. UW/UX Series

    4  Pages

  9. LCMS-8060

    20  Pages

  10. QC Reporter

    6  Pages

  11. OneSight

    4  Pages

  12. TD-30 Series

    12  Pages

  13. Nexis GC-2030

    20  Pages

  14. MOC63u

    6  Pages

  15. UHPLC Nexera X2

    20  Pages

  16. TOC-L

    16  Pages

  17. iMScope Trio

    28  Pages

  18. UV-3600 Plus

    26  Pages

  19. EDX-7000/8000

    24  Pages

  20. LCMS-IT-TOF

    16  Pages

  21. ELB SERIES

    2  Pages

  22. TW TWC SERIES

    8  Pages

*Prices are pre-tax. They exclude delivery charges and customs duties and do not include additional charges for installation or activation options. Prices are indicative only and may vary by country, with changes to the cost of raw materials and exchange rates.