LCMS-IT-TOF

LCMS-IT-TOF
1 / 16 PagesView full catalog

LCMS-IT-TOF

Product catalog summary
Overview: The document details the LCMS-IT-TOF, a high-speed liquid chromatograph mass spectrometer designed for advanced mass analysis. It emphasizes the instrument's capabilities in high-precision MSn measurement, high throughput, and high sensitivity.
Original and Advanced Technology: The LCMS-IT-TOF integrates the MSn capabilities of an ion trap with the resolution and mass accuracy of a TOF. It introduces Compressed Ion Introduction (CII) for efficient ion trapping and Ballistic Ion Extraction (BIE) for high-throughput analysis.
High-Speed and High-Precision MSn Measurement: The instrument offers reliable structural analysis through high-speed mass spectrum measurement and high-speed ion polarity switching, supporting applications in impurity analysis, metabolic profiling, and biomarker research.
Basic Performance Supporting High-Quality Data: The LCMS-IT-TOF ensures high sensitivity and mass accuracy through stable temperature control and effective ion localization, offering extended stability in mass accuracy using an external standard method.
Intelligent Auto MSn Function: This function enhances LC/MS analysis efficiency by automatically selecting precursor ions, including features like monoisotopic peak selection and charge-state filtering.
Software to Accelerate Data Analysis: Optional composition prediction software aids in identifying target constituents with high mass accuracy, facilitating faster data analysis.
Key Technologies: The document references several patented technologies, including Dual-Stage Reflectron and Ballistic Ion Extraction, contributing to the instrument's advanced capabilities.
Composition Prediction Procedure: The procedure involves calculating composition from mass, using isotopic patterns for ranking, and applying MSn spectral filtering to reduce candidate formulas, improving formula identification accuracy.
MetID Solution: This software detects metabolites by comparing control and target sample data, using isotopic patterns and MSn measurements to identify metabolites, even with unknown pathways.
Open Solution ComponentID: This software provides open access to precision mass spectrometry measurements, allowing users to perform analyses and receive formula prediction reports automatically via email.
Profiling Solution Ver. 1.0: This software automates peak detection in multiple data files, creating tables for multivariate analysis, useful for metabolomics and impurities profiling.
Protein Analysis Software: This optional product automates the process from analysis to protein identification, integrating with LCMSsolution for efficient data management and follow-up searches.
Conclusion: The document highlights the LCMS-IT-TOF system and its software's capabilities in enhancing mass spectrometry analyses' accuracy and efficiency, particularly in metabolite detection and protein analysis.
See more

Catalog excerpts

LCMS-IT-TOF-1

Liquid Chromatograph Mass Spectrometer

 Open the catalog to page 1
LCMS-IT-TOF-2

LCMS-IT-TOF H i gh-Spe e d L i q u i d C h r o ma to g ra p h Ma ss S p e ctro me te r LCM S-I T-T O F ® A si g n i fi c a n tly ad van ce d MS detec tor enabling LC / M S n h i g h -p re cisio n mass a nalysis

 Open the catalog to page 2
LCMS-IT-TOF-3

Hig h Resol uti on & Hi gh P re ci si o n i n MS n meas u re me n t T h e s t a b l e , h i gh - re so lu tio n sp e ctra a ch ie ve d throughout a wide mass range and high-precision MS n data are der i v e d f r o m t h e DSR : Du a l- Sta g e R e fle ctro n (* 1 ) and the use of BIE: Ballistic Ion Extraction (*2) . These instrument a d v a n c e s c a n s tro n g ly a ssist in th e u se o f MS for predicting accurate structural details. Hig h Throughput I n c r e a s e d a m o un ts o f in fo rma tio n a re o b ta in e d for each measurement, enabling much higher reliability in struct u r a...

 Open the catalog to page 3
LCMS-IT-TOF-4

Original and Advanced Technology W hat i s th e I T - T O F ? There are several types of LC/MS instruments in the market currently. The single quadrupole and triple quadrupole instruments are primarily used for quantitative analysis, while the ion trap, LC-TOF and Qq-TOF instruments are primarily used for qualitative analysis. Triple quadrupoles are excellent instruments for quantitative analysis, although they falter in comparison to other types of mass spectrometers in terms of mass accuracy and resolution. Ion traps excel in structural analysis due to their ability to perform MS n; however,...

 Open the catalog to page 4
LCMS-IT-TOF-5

Atmospheric Ionization Probe Octopole lens In the LCMS-IT-TOF, rather than simply combining the existing technologies of the QIT (Quadrupole Ion Trap) mass spectrometer and an oaTOF (Orthogonal Acceleration Time of Flight) mass spectrometer, the QIT and TOF are arranged linearly in a unique construction. This construction offsets the disadvantages of slow measurement Flight tube with temperature control Dual-Stage Reflectron speed, ion capture rate and trap saturation associated with the ion trap, while allowing the advantages of the ion trap and TOF to be fully demonstrated. Abundant qualitative...

 Open the catalog to page 5
LCMS-IT-TOF-6

High-Speed and High-Accuracy MS n Measurement The LCMS-IT-TOF is intended to strongly assist in the identification of target compounds by using high-speed/high-accuracy MSn data in R&D fields such as impurity analysis, metabolic profiling and biomarker research. Half Height Peak Width: 1.2 sec External Standard Method The data above shows the analysis of four compounds within 2.0 minutes. The Auto MSn function makes it possible to obtain highly accurate MSn data via an external standard, taking advantage of high-speed mass spectrum measurement performance. : 0.1 % formic acid in methanol Time...

 Open the catalog to page 6
LCMS-IT-TOF-7

Ion fragmentation is very useful in structural analysis. The LCMS-ITTOF has a unique design in that it connects an ion trap with a TOF and provides high-precision mass information for either MS or MSn. This makes it possible to perform highly reliable structural analysis. External Standard Method The above examples show that the low-mass product ions can be analyzed precisely and the new compounds can be identified by MSn measurement. Sample provided by: AstraZeneca (UK) Dr. Richard Gallagher LCMS-IT-TOF Liquid Chromatograph Mass Spectrometer

 Open the catalog to page 7
LCMS-IT-TOF-8

Basic Performance Supporting High-Quality Data Com pat i b i l i t y o f H i g h S e nsitiv ity a n d Ma ss Accu ra cy 1 00 at t om ol of Fibrinope ptide A E xt ended S t a b i l i t y i n Ma s s Accu ra cy The high-accuracy temperature control mechanism of the flight tube, the localized ion due to BIE from the QIT, and the effective 10-bit high-speed transient recorder enable extremely stable mass accuracy using the external standard method. Due to labor-intensive work required when using an internal standard for LC/MS anal- External Standard Method (m/z 1064: NaTFA) ysis, it is extremely important...

 Open the catalog to page 8
LCMS-IT-TOF-9

H i gh-Spe e d I o n P o l a r i t y S witch in g Mo d e [ u p to 2 .5 Hz] Voltage change monitored with an oscilloscope 10 8 3 4 2 High-Speed Ion Polarity Switching can be especially useful when it cannot be judged whether samples will be detected as positive or negative ions. The LCMS-IT-TOF utilizes a newly developed, highly accurate and stable power supply as well as a newly developed high-voltage switch that allows for polarity switching in only 0.1 sec or less (necessary for the sharp HPLC peaks available with the advances in high-speed chromatography). The maximum rate for polarity switching...

 Open the catalog to page 9
LCMS-IT-TOF-10

Intelligent Auto MS n Function What i s th e A u t o MS n F u n ctio n ? Samples cannot be recaptured once injected for LC/MS analysis; therefore, it is vital that instruments can automatically select the appropriate precursor ions. With the LCMS-IT-TOF, a variety of precursor ion selection criteria, such as the selection of ions in order of intensity or m/z is available, in addition to intelligent automatic precursor selection, such as a monoisotopic peak selector and chargestate filtering. Main Functions for Precursor Ion Selection Selection in the order of intensity or m/z Charge state filter...

 Open the catalog to page 10
LCMS-IT-TOF-11

E xam pl es H i g h l i g h t i n g t h e Ne u tra l Lo ss S u rv e y Fu n ctio n The combination of the neutral loss survey and MS3 measurement provides accurate mass information that can lead to highly reliable structural analyses of phospholipids. Polar radical-specific neutral loss (NL) Polar radical information CH -O-CO-R 2 MS 3 measurement : Lipid chain information Setting PS (Polar radical X : serine) - specific NL (87 Da) and performing the neutral loss survey PC : Phosphatidilcholine PS : Phosphatidilserine PA : Phosphatidic acid FA : Fatty acid [M+CH 3COO] - for diacyl 36:6 PC Expected...

 Open the catalog to page 11
LCMS-IT-TOF-12

Software to Accelerate Data Analysis C om pos i ti o n P r e d i c t i o n S o ftwa re ( Op tio n a l p ro d u ct) E f f ect ivenes s of Acc ura te M S n In composition prediction, target constituents having a small mass and high mass accuracy associated with their measured values, provide fewer numbers of candidates and greater prediction reliability. When using MS2 data with the Composition Prediction Software, formula prediction starts with the product ion having the smallest mass, and uses that result in the effective prediction of the parent ion by reducing the number of candidates. Mass...

 Open the catalog to page 12

All Shimadzu France catalogs and technical brochures

  1. LCMS-2050

    16  Pages

  2. MCT Series

    12  Pages

  3. LC/MS/MS

    2  Pages

  4. SALD-7500nano

    16  Pages

  5. LC/MS/MS MRM

    2  Pages

  6. LC/MS/MS

    2  Pages

  7. TRViewX

    8  Pages

  8. UW/UX Series

    4  Pages

  9. LCMS-8060

    20  Pages

  10. QC Reporter

    6  Pages

  11. OneSight

    4  Pages

  12. TD-30 Series

    12  Pages

  13. Nexis GC-2030

    20  Pages

  14. MOC63u

    6  Pages

  15. UHPLC Nexera X2

    20  Pages

  16. TOC-L

    16  Pages

  17. RF-6000

    24  Pages

  18. iMScope Trio

    28  Pages

  19. UV-3600 Plus

    26  Pages

  20. EDX-7000/8000

    24  Pages

  21. ELB SERIES

    2  Pages

  22. TW TWC SERIES

    8  Pages

*Prices are pre-tax. They exclude delivery charges and customs duties and do not include additional charges for installation or activation options. Prices are indicative only and may vary by country, with changes to the cost of raw materials and exchange rates.