1. Catalogs
  2. Shimadzu France
  3. LC-2010 Integrated HPLC System

LC-2010 Integrated HPLC System
1 /3Pages

LC-2010 Integrated HPLC System

LC-2010 Integrated HPLC System
1 /3Pages

Catalog excerpts

LC-2010 Integrated HPLC System-1

Shimadzu Europa GmbH www.shimadzu.de Albert-Hahn-Str.6-10 47269 Duisburg Specification Sheet LC-2010 Integrated HPLC System LC-2010C LC-2010A Pump type Serial dual plunger, micro volume (10 ìL on primary side, 5 ìL on secondary) Flow rate setting range 0.001 ~ 5 mL/min. (1.0 - 35.0 MPa) Flow rate accuracy ± 1% (1 mL/min, 3.0 - 10.0 MPa, using water and fixed ambient temperature of 20°C, except during gradient solvent delivery), ± 2% (except for above conditions) or ± 2 ìL/min, whichever is greater Flow rate precision 0.075% RSD or 0.02 min SD, whichever is greater (0.05 - 2 mL/min, 1.0 - 35.0 MPa, methanol 20°C constant temperature) Number of solvents and setting range Up to 4 solvents 0 to 100%, 0.1% steps Concentration accuracy ± 0.5% (aqueous acetone/water, binary gradient, flow rate 0.1 - 2.0 mL/min, pressure 1.0 - 20.0 MPa) Pump LPGE Concentration precision ± 0.1% (aqueous acetone/water, binary gradient, flow rate 0.1 - 2.0 mL/min, pressure 1.0 - 20.0 MPa)

 Open the catalog to page 1
LC-2010 Integrated HPLC System-2

Shimadzu Europa GmbH www.shimadzu.de Albert-Hahn-Str.6-10 47269 Duisburg Specification Sheet: LC-2010 Integrated HPLC System (2/3) LC-2010C LC-2010A Injection Method Variable volume injection possible (without sample loss) Injection volume setting range 0.1 - 100 ìL (standard), 1 - 2000 ìL (optional) (0.1 - 0.9 ìL on 0.1 ìL steps, 1 to 2000 ìL in 1 ìL steps) 1 mL vial 350 1.5 mL vial 140 210 4 mL vial 100 MTP 4 96- or 384-well micro titer plates Sample capacity DWP 4 96-well deep-well plates Injection repeatability RSD < 0.3% (with 10 ìL injections) Carry over 0.01% (under napthalene analysis...

 Open the catalog to page 2
LC-2010 Integrated HPLC System-3

Shimadzu Europa GmbH www.shimadzu.de Albert-Hahn-Str.6-10 47269 Duisburg Specification Sheet: LC-2010 Integrated HPLC System (3/3) LC-2010C LC-2010A Light source Deuterium lamp Wavelength Range 190 - 600 nm Bandwidth 8 nm Wavelength accuracy ± 1 nm Wavelength precision ± 0.1 nm Drift 1x10-4 AU/h (250 nm air cell) Noise level ± 0.25 x 10-5 AU (for response of 1 s, 250 nm, air cell) Cell path length, cell volume 10 mm, 8 ìL (STD flow cell), 5 mm, 2.4 ìL (semimicro flow cell) UV Detector 2 wavelengths monitoring Any two wavelengths from 190 - 370 nm or 371 - 600 nm Display Backlit liquid crystal...

 Open the catalog to page 3

All Shimadzu France catalogs and technical brochures

  1. LCMS-2050

    16  Pages

  2. MCT Series

    12  Pages

  3. LC/MS/MS

    2  Pages

  4. SALD-7500nano

    16  Pages

  5. LC/MS/MS MRM

    2  Pages

  6. LC/MS/MS

    2  Pages

  7. TRViewX

    8  Pages

  8. UW/UX Series

    4  Pages

  9. LCMS-8060

    20  Pages

  10. QC Reporter

    6  Pages

  11. OneSight

    4  Pages

  12. TD-30 Series

    12  Pages

  13. Nexis GC-2030

    20  Pages

  14. MOC63u

    6  Pages

  15. UHPLC Nexera X2

    20  Pages

  16. TOC-L

    16  Pages

  17. RF-6000

    24  Pages

  18. iMScope Trio

    28  Pages

  19. UV-3600 Plus

    26  Pages

  20. EDX-7000/8000

    24  Pages

  21. LCMS-IT-TOF

    16  Pages

  22. ELB SERIES

    2  Pages

  23. TW TWC SERIES

    8  Pages

*Prices are pre-tax. They exclude delivery charges and customs duties and do not include additional charges for installation or activation options. Prices are indicative only and may vary by country, with changes to the cost of raw materials and exchange rates.