1. Catalogs
  2. Shimadzu France
  3. ICPE-9800 series

ICPE-9800 series

ICPE-9800 series
1 / 20 PagesView full catalog

ICPE-9800 series

Product catalog summary
Overview of ICPE-9800 Series: The ICPE-9800 Series are advanced ICP atomic emission spectrometers designed for accurate, rapid multi-element analysis across various concentration levels. They are user-friendly and cost-effective, suitable for fields like environmental, pharmaceutical, food, chemical, and metal industries.
Key Features:
  • Enhanced Throughput: Offers a broad dynamic range from ppb to percent levels for comprehensive analysis.
  • Optimal Methods: All-wavelength acquisition system detects matrix influences for accurate analysis.
  • Reduced Operating Costs: Features like Eco mode and Mini-torch system reduce argon gas consumption.
Applications:
  • Food Products/Agriculture: Provides reliable data for food safety and nutritional labeling.
  • Environment/Water Analysis: High sensitivity and stability for environmental regulations and water safety.
  • Medical/Pharmaceutical: Complies with 21 CFR Part 11 and ICH Q3D guidelines for drug analysis.
  • Chemicals/Petrochemicals: Manages trace hazardous metals and additives efficiently.
  • Metals/Mining/Electrical and Electronic: Ensures high accuracy and stability for complex samples.
Technical Innovations:
  • Vertical Torch Orientation: Minimizes memory effects for stable analysis.
  • CCD Detector: Large sensor captures data for all wavelengths, enabling post-measurement changes.
  • Gas Consumption Reduction: Mini Torch and Eco Mode halve gas usage.
  • Vacuum Spectrometer: Ensures fast startup and reduced gas consumption.
Conclusion: The ICPE-9800 Series offers high performance, cost efficiency, and regulatory compliance, making it versatile for various industries.
Software Features:
  • Smart Assist: Simplifies analysis by guiding users through method selection and calibration.
  • Acquisition for All Wavelengths: Allows post-measurement addition of elements and wavelengths.
  • Method Optimization: Automatic wavelength selection and interelement correction ensure accuracy.
Standard Accessories and Options:
  • Includes torches, nebulizers, and chambers for specific sample types.
  • Offers autosamplers for automatic analysis of multiple samples.
  • Quality control software ensures regulatory compliance.
Peripheral Equipment: Additional equipment like cooling water circulators and ultrasonic nebulizers enhance capabilities.
Specifications:
  • Temperature and Humidity: Installation room should maintain 18°C to 28°C and 20% to 70% humidity.
  • Power Supply: Requires a single-phase power supply of 200/220/230/240 V ± 10%, 50/60 Hz.
  • Grounding: Independently grounded with a maximum resistance of 30 Ω.
  • Gas Equipment: Requires argon gas with 99.95% purity, supplied at 450 ± 10 kPa.
  • Cooling Water: Requires cooling water with a temperature between 5°C to 30°C.
  • Exhaust Duct: Necessary for managing argon and potential vapors.
Installation Requirements:
  • Main Unit: Weighs 210 kg and requires specific power and grounding setups.
  • Options: Includes a cooling water circulator and vacuum pump.
Additional Information: The product is for research use only and information is subject to change without notice.
See more

Catalog excerpts

ICPE-9800 series-1

Simultaneous ICP Atomic Emission Spectrometers

 Open the catalog to page 1
ICPE-9800 series-2

BEST for all laboratories ICPE-9800 Series of simultaneous ICP atomic emission spectrometers are next-generation systems that offer the superior accuracy necessary to simultaneously and quickly analyze multiple elements regardless of their concentration levels. They also feature user-friendly software that makes analysis easy. Furthermore, the systems reduce analysis costs while providing the highest performance levels in the industry. ICPE-9800 Series systems represent the ultimate in ICP atomic emission spectrometry for environmental, pharmaceutical, food, chemical, metal, and other fields....

 Open the catalog to page 2
ICPE-9800 series-3

Enhanced throughput Optimal methods Reduced operating costs Regulations addressing hazardous elements have become increasingly stringent, as the demand grows for food safety. Moreover, labeling that lists the nutritional content of foods, in accordance with defined nutrition labeling standards, is now mandatory in many places. Such labeling generally includes minerals and other components that support a balanced diet and an individual's health. In the area of food products, it has become increasingly important for analytical instruments to efficiently produce highly reliable data over a broad...

 Open the catalog to page 3
ICPE-9800 series-4

► Automatic correction for spectral interference ► No need for oxygen when introducing organic solvents Plans are proceeding for the establishment of the ICH Q3D guideline, which aims at harmonization among the regulatory authorities in Japan, the U.S., and the EU concerning the analysis of elemental impurities in drugs. It is expected that regulations by individual authorities will be accordingly revised. As part of the quality control measures for pharmaceuticals, detection limits must meet the stringent permitted daily exposure (PDE) values. Validation is also important to guarantee the reliability...

 Open the catalog to page 4
ICPE-9800 series-5

Chemicals / Petrochemicals Stable injection of organic solvent samples and high-salt samples User-friendly sof tware Reduced operating costs In the chemical field, ICP-AES is used for a broad range of analysis in order to manage trace amounts of hazardous metals in the manufacturing process, manage additive elements essential to the functionality of a product, and manage the environment of the entire factory. Therefore, it is desirable to have a robust, highly stable system able to reliably accept the injection of a broad variety of samples, regardless of the type of solvent (aqueous/organic)...

 Open the catalog to page 5
ICPE-9800 series-6

High Performance System Design Helps Ensure Maximum Performance Photometric System Highly Suitable for the Analysis of a Wide Variety of Samples Leading-Edge CCD Detector with One Million Pixels Capable of Simultaneous Recording of All Wavelengths Three Features Reduce Gas Consumption by Half

 Open the catalog to page 6
ICPE-9800 series-7

Highly Suitable for the Analysis of a Wide Variety of Samples Simultaneous Analysis of Trace and High-Concentration Samples Without Concern for Contamination The torch is oriented vertically to minimize any adhesion of sample on the torch walls, thus reducing memory effects. Simultaneous analysis is possible by switching between axial and radial views. Radial view Axial view Cooling jacket Mirror Cooling jacket Mirror Mirror Monochromator ochromator m Monochromator Orifice • Sample solutions fall easily. solution f ns gged easily. ily. y • Not clogged easily Pu Purge gas Light Light Plasma Plasma...

 Open the catalog to page 7
ICPE-9800 series-8

Leading-Edge CCD Detector with One Million Pixels Capable of Simultaneous Recording of All Wavelengths Data for all wavelengths are captured as an image formed on a two-dimensional plane using a large 1-inch CCD sensor, in the same way that a camera captures a photograph. The acquired data are saved for reviewing at any time. The wavelength can be changed after the measurement is finished, thus reducing the need to reanalyze samples and enabling faster method development. In addition, qualitative data can be read and matrix elements can be checked and corrected for, thus eliminating measurement...

 Open the catalog to page 8
ICPE-9800 series-9

Three Features Reduce Gas Consumption by Half Gas Usage During Analysis and Standby Halved Mini Torch Mini-torch is designed to have only half the cross sectional area of standard torches. Applying the same high-frequency output to the smaller cross section increases the energy density per cross section. This improves the excitation efficiency, resulting in higher sensitivity. Reducing the high-frequency output to 0.5 kW and the plasma gas flow rate to about 5 L/min during standby saves energy and reduces costs. The analysis mode starts up smoothly as well, which enables stable analysis. 0 Standard...

 Open the catalog to page 9
ICPE-9800 series-11

ICPEsolution Software Ensures That Analysis Can Be Started Smoothly Start measurements easily by simply clicking icons on the assistant bar in order. Select the analytical method System methods: Methods (with plasma conditions and other settings) optimized for the sample injection system are available. User methods: Methods used on a routine basis can be specified and registered. Calibrate the instrument (wavelength calibration) Standard samples are not necessary for wavelength calibration. Simultaneous ICP Atomic Emission Spectrometer

 Open the catalog to page 11
ICPE-9800 series-12

Acquisition for All Wavelengths and Assistant Functions Ensure a Smoother Analysis Process The ICPE-9800 series' assistant functions, which combine extensive spectral data with a substantial database, enable easy optimization of methods and a simpler, more efficient analytical workflow. Prepare sample. Select elements and d wavelengths. Prepare calibration curve. e. Measure. Acquisition for All Wavelengths Additional data can be loaded later, which eliminates the need to analyze samples again. 1. The user forgot to register elements and wavelengths. Selected wavelength resulted in an overflow....

 Open the catalog to page 12
ICPE-9800 series-13

Acquisition for All Wavelengths Allows You to Freely Add Elements and Wavelengths Acquisition for All Wavelengths Even after measurements are finished, the elements and wavelengths can be added, which allows you to confirm the quantitative or qualitative data. Because data are acquired for all wavelengths, there is no need to reanalyze samples. Adding Quantitative Analysis Adding Qualitative Analysis Reanalyzing Data from Previous Analyses The quantitative values can be displayed by simply adding elements or wavelengths. This is especially helpful when you forgot to specify an element to be measured...

 Open the catalog to page 13

All Shimadzu France catalogs and technical brochures

  1. LCMS-2050

    16  Pages

  2. MCT Series

    12  Pages

  3. LC/MS/MS

    2  Pages

  4. SALD-7500nano

    16  Pages

  5. LC/MS/MS MRM

    2  Pages

  6. LC/MS/MS

    2  Pages

  7. TRViewX

    8  Pages

  8. UW/UX Series

    4  Pages

  9. LCMS-8060

    20  Pages

  10. QC Reporter

    6  Pages

  11. OneSight

    4  Pages

  12. TD-30 Series

    12  Pages

  13. Nexis GC-2030

    20  Pages

  14. MOC63u

    6  Pages

  15. UHPLC Nexera X2

    20  Pages

  16. TOC-L

    16  Pages

  17. RF-6000

    24  Pages

  18. iMScope Trio

    28  Pages

  19. UV-3600 Plus

    26  Pages

  20. EDX-7000/8000

    24  Pages

  21. LCMS-IT-TOF

    16  Pages

  22. ELB SERIES

    2  Pages

  23. TW TWC SERIES

    8  Pages

*Prices are pre-tax. They exclude delivery charges and customs duties and do not include additional charges for installation or activation options. Prices are indicative only and may vary by country, with changes to the cost of raw materials and exchange rates.