LC/MS Ultra Fast Amino Acid Analysis System UF-Amino Station
12Pages

{{requestButtons}}

Catalog excerpts

LC/MS Ultra Fast Amino Acid Analysis System UF-Amino Station - 1

LC/MS Ultra Fast Amino Acid Analysis System UF-Amino Station

Open the catalog to page 1
LC/MS Ultra Fast Amino Acid Analysis System UF-Amino Station - 2

New UF-Amino Station Offers Simultaneous Analyze 38 amino acid components in just nine minutes! Reversed-phase chromatography + precolumn derivatization + UV detection 160 minutes Ion-exchange chromatography h + postcolumn derivatization Start analysis Two major problems exist with traditional amino acid analysis special-purpose, fast analysis column and a LCMS-2020 mass techniques. The first technique (ion-exchange chromatography spectrometer, which supports ultra-fast analysis speeds, to with postcolumn derivatization) allows many components to be achieve the simultaneous analysis of 38...

Open the catalog to page 2
LC/MS Ultra Fast Amino Acid Analysis System UF-Amino Station - 3

Multicomponent Analysis for Enhanced Throughput Opening Up a New World of Amino Acid Analysis Fast Simultaneous Analysis of 38 Amino Acid Components in Nine Minutes The combination of a special-purpose, fast-analysis column and LC/MS allows for shorter analysis times than conventional techniques. 0.0 Analysis of 38 components in nine minutes AmiNavi ™ Software Simplifies Operation Analyze a sample quickly and efficiently with AmiNavi dedicated software, which provides complete support for the full range of analysis operations. AmiNavi Software LC/MS Offers Superb Detection Selectivity Using...

Open the catalog to page 3
LC/MS Ultra Fast Amino Acid Analysis System UF-Amino Station - 4

Fast Simultaneous Analysis of 38 Amino Acid Components in Nine Minutes Rapid separation combined with LC/MS detection results in the simultaneous analysis of 38 biogenic amino acid components in just nine minutes. The ability to analyze up to 96 samples in 24 hours ensures exceptional performance for multi-sample analysis. The increased speed supports new applications, such as real-time amino acid composition analysis in culture fluid, that were difficult to handle using conventional techniques. About 18 Times Faster Biogenic amino acid analysis using a combination of ion-exchange...

Open the catalog to page 4
LC/MS Ultra Fast Amino Acid Analysis System UF-Amino Station - 5

LC/MS Offers Superb Detection Selectivity A method using precolumn derivatization and UV detection combined with reversed-phase column separation can be used to reduce analysis times. However, it may not achieve adequate separation and the reliability of the analysis results may be limited in cases with numerous target components, such as biogenic amino acids, or if the sample contains many impurities. By using an LC/MS instrument as the detector, UF-Amino Station permits highly reliable analysis even when analyzing a large number of target components or if the sample contains a complex...

Open the catalog to page 5
LC/MS Ultra Fast Amino Acid Analysis System UF-Amino Station - 6

AmiNavi™ Dedicated Software Simplifies Operation AmiNavi software supports all operations from analysis setup to checking quantitation results AmiNavi completely eliminates the need or time to create complex method files or sequence files. Simply install the column, the mobile phase, and the autosampler rinse solution on the system and then run AmiNavi. The software guides the user through the rest of the parameters in order to create an analytical sequence. Once Simply follow the on-screen wizard to create analysis sequences, check analysis results, or print reports completed, load the...

Open the catalog to page 6
LC/MS Ultra Fast Amino Acid Analysis System UF-Amino Station - 7

AmiNavi displays the quantitation results when the analysis is complete. It automatically identifies standard sample peaks, creates the calibration curve, and performs quantitation of the sample solution. This makes it simple to observe the quantitation results for multiple samples without the need to perform any difficult or time-consuming analysis operations. The report template can be used to generate a quantitation results report with just one click Checking the Analytical Results Display of analytical results Table Displaying the Analytical Results The amino acid content of each sample...

Open the catalog to page 7
LC/MS Ultra Fast Amino Acid Analysis System UF-Amino Station - 8

Automated Derivatization Improves Efficiency and Reliability The UF-Amino Station automatic pretreatment functions improve the efficiency of the derivatization process and enhance the reliability of the results. Simply load the samples and reaction reagents, and the instrument automatically completes the series of operations from derivatization to injection into the HPLC. Derivatization by Automatic Pretreatment Sample loop Drain Reaction unit Automatic mixing Reaction reagent Analysis samples From pump The autosampler pretreatment functions are used to draw in the sample and reaction...

Open the catalog to page 8
LC/MS Ultra Fast Amino Acid Analysis System UF-Amino Station - 9

Automatic Pretreatment Enhances Reliability of Analysis Results UF-Amino Station uses automatic pretreatment to ensure a more stable derivatization reaction. The excellent selectivity of LC/MS detection achieves high recovery rates for complex samples such as skim milk powder. Correction by an internal standard ensures adequate reproducibility and calibration curve linearity. Thr Area ratio Retention time Reproducibility of Area Ratio and Retention Time (n=6, concentration=500 nmol/mL, each component) (Internal Standard Correction) Amino Acid Recovery Rates for Commercial Skim Milk Powder...

Open the catalog to page 9
LC/MS Ultra Fast Amino Acid Analysis System UF-Amino Station - 10

Diverse Applications Using UF-Amino Station Analysis of meat extracts using PTC pre-column derivatization and UV detection results in amino acid peaks that overlap each other or suffer matrix interference, which often impair the accuracy of quantitation. UF-Amino Station exploits the high selectivity of LC/MS to offer accurate detection and quantitation, even in complex matrices like meat extracts or culture fluids. Naturally, it can also be applied to the conventional quantitative analysis of amino acids in beverages and fermented foods. Reliable Analysis of Samples with Significant...

Open the catalog to page 10
LC/MS Ultra Fast Amino Acid Analysis System UF-Amino Station - 11

Faster Analysis of Food and Biological Samples An excellent tool for the analysis of multiple samples in the fields of foods and biochemistry, UF-Amino Station improves analytical efficiency, even for samples such as beverages and blood plasma for which amino acid analysis is already established. Analysis of Amino Acids in Commercial Tea Drink Analysis of Amino Acids in Commercial Beer Ala Glu Analysis of Amino Acids in Rat Blood Plasma UF-Amino Station LC/MS Ultra Fast Amino Acid Analysis System

Open the catalog to page 11
LC/MS Ultra Fast Amino Acid Analysis System UF-Amino Station - 12

Shimadzu Solutions for Amino Acid Analysis ° Besides UF-Amino Station, Shimadzu offers an extensive range of other products suitable for amino acid analysis. 5' yyy : Best; yy : OK; y : Partially OK; n/a: Unsuitable Contact your Shimadzu representative for details AmiNavi is a registered trademark of Ajinomoto Co., Inc. Shimadzu Corporation Company names, product/service names and logos used in this publication are trademarks and trade names of Shimadzu Corporation or its affiliates, whether or not they are used with trademark symbol "TM" or "®". Third-party trademarks and trade names may...

Open the catalog to page 12

All Shimadzu Europa catalogs and technical brochures

  1. TD-30 Series

    12 Pages

  2. Nexis GC-2030

    20 Pages

  3. MOC63u

    6 Pages

  4. TOC-L

    16 Pages

  5. RF-6000

    24 Pages

  6. iMScope Trio

    28 Pages

  7. UV-3600 Plus

    26 Pages

  8. EDX-7000/8000

    24 Pages

  9. LCMS-IT-TOF

    16 Pages

  10. ELB SERIES

    2 Pages

  11. UW/UX SERIES

    4 Pages

Archived catalogs

  1. TOC-4110

    1 Pages