Catalog excerpts
With Advanced Flow Technology CAPILLARY GAS CHROMATOGRAPH SYSTEM The Shimadzu GC-2010 Plus represents a new generation in top end capillary GC analysis, redefining sensitivity limits for trace analysis, fast GC applications, and easy, robust operation. Advanced Flow Technology (AFT) capability further extends the applications scope of the instrument allowing multidimensional GC, capillary backflush, and other specialized flow applications. AFT additionally enables reduced analysis times, enhanced chromatographic resolution, and application-specific configurations without compromising key...
Open the catalog to page 2Advanced Flow Technology Advanced Flow Technology is Shimadzu´s solution to provide enhanced separation power and operational efficiency for applications with complex sample matrices. This enhanced capability is based on the high precision Advanced Flow Control (AFC) of the GC-2010 Plus. Advanced Flow Technology for high-performance separation Multi-dimensional GC/GCMS System MDGC/GCMS-2010 M u l t i -Dean s ’ Sw i t c h i n g In the past, multidimensional GC has been accomplished using a switching mechanism known as Deans’ Switch. However, this system results in such problems as a reduced...
Open the catalog to page 4Multi-Switching Analysis of Essential Oil Oven temp Split ratio Oven temp H2: 50 mL/min, Air: 400 mL/min, Make-up: 0 mL/min 8 compounds are switched onto the 2nd column 8 compounds are separated into 15 peaks Universita degli Studi di Messina Prof. Luigi Mondello Alessandro Casill Peter Quinto Tranchida Danilo Sciarrone Chromatogram Obtained with 1st Column Heart-cut positions
Open the catalog to page 5Advanced Flow Technology for Enhanced Productivityand Confident Identification Backflush System The backflush system reverses the carrier gas flow after the target compounds have eluted, to discharge residual late eluting components in the column through the injection port split vent. Backflush shortens the analysis time and improves productivity. In addition, high-boiling point components are discharged efficiently to reduce the bakeout time (elution time), and thus prevent column deterioration, contamination, and retention time shifts. Normal Analysis Unnecessary component Analysis time...
Open the catalog to page 6The Intuitive and easy-to-use Advanced Flow Technology Software is included with each AFT system. Both the backflushing and detector splitting systems are controlled with this software. Analysis of Volatile Compounds in Polystyrene Backflushing was started 12 minutes after target substances were eluted. Analysis time, including the time for discharging unwanted substances, could be reduced from 75 minutes to 18.5 minutes. * Open__j Save j Configuration. Iprfipcratyrc Cg_fcjmn Ftaw CoEumn Lenalh Film Thickness Flow Control mode Total Flii» Fur-up. Finn Spirt KathD Advanced Flow Technology...
Open the catalog to page 7Industry Leading Detector Sensitivity Responding to the ever increasing demands for trace level analysis, our new detectors boast the highest sensitivity in the industry. The new Flame Photometric Detector (FPD) and Flame Ionization Detector (FID) show significantly increased sensitivity. FID-2010 Plus Minimum Detected Quantity:1.5 pgC/s* FID-2010 Plus gives you the world’s highest FID sensitivity with clean detector gas flows and the latest noise reduction technology. High-sensitivity has been achieved by thorough cleaning of detector gas lines and the latest noise-reduction technology....
Open the catalog to page 8Flame Photometric Detector A new FPD design featuring improved flame stability and double focusing optics has produced an FPD with the world's highest sensitivity. This has all been achieved in a compact design that fits within the detector bay. The dual-focus system adds a lens to the interference filter for efficient light collection at the photomultiplier light Minimum Detected Quantity: 55 fgP/s (phosphorus compounds) 3 pgS/s (sulfur compounds) l_ens Photomultiplier P mode: Analysis of 5 ppb Organo-Phosphorus Pesticides S Mode: Analysis of 20 ppb Thiophene in Benzene
Open the catalog to page 9Industry Leading Detector Sensitivity El e c tro n C a p tu re D ete cto r* Thermal Conduc tivity Detec tor A highly sensitive and selective detector for the analysis of electrophilic compounds. Top class sensitivity results from upgraded cell insulation and a cell/flow line design to reduce contamination. Compact design achieves shorter stabilization times. ECD cell is common with that for GC-2010 (ECD-2010). *In some countries, registration with the appropriate authority for regulation of radioisotopes is required before purchasing or using this detector. (Contact your Shimadzu...
Open the catalog to page 10Highly Evolved Design Delivers Analytical Productivity H i g h - S p e e d A n aly sis High-speed analysis with narrow bore capillary columns reduces analysis time and improves sample throughput. The new-generation digital flow rate controller (AFC) provides 970 kPa maximum operating pressure and 1200 mL/min total flow to support high-speed analysis. High-Speed Analysis of Coffee Flavoring Analysis time with conventional conditions DB-WAX 0.25mm×60m, 0.25µm ( He 25cm/s ) Analysis time reduced by GC-2010 Plus B a c k fl u s h R ed u ces A n aly sis T ime The Backflush technique is effective...
Open the catalog to page 11Ra p i d O v e n H ea tin g * / C o o lin g The GC-2010 Plus incorporates a double-jet cooling system, consisting of an exhaust fan to discharge hot air and an intake fan to draw in cooling air. The system enables the reduction of cooling time from 450°C to 50°C in 3.4 min. Double-jet cooling system Large fan rapidly discharges hot air. Small fan added to enhance efficiency of cooling air intake Column oven temperature (°C) Hydrocarbon analysis in conventional mode Total analysis time: 28.7 min. Hydrocarbon analysis with GC-2010 Plus high power oven model (230V) Total analysis time: 15.2...
Open the catalog to page 12R e p e a ta b i l ity R esettin g th e Limits All units including the column oven, flow controller, and sample injection unit are comprehensively optimized at the design stage to achieve world-class precision. Gas Saver Func tion Reduc es Car r ier Gas Us age The GC-2010 Plus features a gas saving function that considerably reduces carrier gas consumption. In the split/ splitless sample injection mode, the split ratio can be reduced after injection and during stand-by. Simultaneous ly ins tall up to th ree injec tion units and up to four detec tors Select from three injection units and...
Open the catalog to page 13All Shimadzu Europa catalogs and technical brochures
-
TD-30 Series
12 Pages
-
Nexis GC-2030
20 Pages
-
ATX/ATY series
4 Pages
-
MOC63u
6 Pages
-
UHPLC Nexera X2
20 Pages
-
TOC-L
16 Pages
-
RF-6000
24 Pages
-
iMScope Trio
28 Pages
-
ICPE-9800 series
20 Pages
-
UV-3600 Plus
26 Pages
-
EDX-7000/8000
24 Pages
-
Capillary GC-2010 Plus
24 Pages
-
LCMS-IT-TOF
16 Pages
-
Headspace Sampler HS-20
8 Pages
-
BW-K/BX-K Series
2 Pages
-
Catalog MOC 120H
4 Pages
-
ELB SERIES
2 Pages
-
TW TWC SERIES
8 Pages
-
UW/UX SERIES
4 Pages
-
AUW-D/AUW/AUX/AUY Series
8 Pages
-
Catalog UW-Series
6 Pages
-
Catalog AU-Series
8 Pages
-
MDGC-2010 system
1 Pages
Archived catalogs
-
Catalogue HMV-2 Series
8 Pages
-
TOC-4110
1 Pages
-
Shimadzu FTIR Overview
4 Pages
-
Shimadzu Software Overview
8 Pages
-
Shimadzu GC/GCMS Overview
6 Pages
-
Shimadzu LC/LCMS Overview
12 Pages
-
Shimadzu X-ray Fluorescence
2 Pages