Energy Dispersive X-ray Fluorescence Spectrometer
Open the catalog to page 1EDX-7000/8000 Energy Dispersive X-ray Fluorescence Spectrometer
Open the catalog to page 3Principle and Features of X-ray Fluorescence Spectrometry Principle of Fluore scent X- ray Generation When a sample is irradiated with X-rays from an X-ray tube, the atoms in the sample generate unique X-rays that are emitted from the sample. Such X-rays are known as "fluorescent X-rays" and they have a unique wavelength and energy that is characteristic of each element that generates them. Consequently, qualitative analysis can be performed by investigating the wavelengths of the X-rays. As the fluorescent X-ray intensity is a function of the concentration, quantitative analysis is also...
Open the catalog to page 4Primary filter X-ray tube
Open the catalog to page 5Unrivale d A naly tic al Per formance The high-performance SDD detector and optimized hardware achieve a high level of sensitivity, analysis speed, and energy resolution that were previously unattainable. The EDX-8000 system also permits detection from 6C. High Sensitivity − Lower Limit of Detection Improved 1.5 to 5 Times! − The high-performance SDD detector and combination of optimized optics and primary filters achieve previously unheard-of high levels of sensitivity. The sensitivity is higher than the previous Si (Li) semiconductor detector across the entire range from light to heavy...
Open the catalog to page 6High Resolution The EDX-7000/8000 instruments achieve superior energy Previous model resolution compared to previous models by incorporating a state-of-the-art SDD detector. This reduces the effects of overlapping peaks of different elements, enhancing the reliability of the analysis results. Comparison of Energy Resolutions (sample: PPS resin) No Liquid Nitrogen Required The SDD detector is electronically cooled, eliminating the need for cooling by liquid nitrogen. This frees the user from the chore of replenishing the liquid nitrogen and contributes to lower running costs. Range of Dete c...
Open the catalog to page 7E x tremely Flexible Accommodates all types of samples from small to large, from powders to liquids. Options include a vacuum measurement unit and helium purge unit for highly sensitive measurement of light elements and a 12-sample turret for automated continuous measurements. Sample Ob ser vation C amera and Collimator s Automatic collimator switching in four stages: 1, 3, 5, and 10 mm diameter Select the irradiation chamber from four values to suit the sample size. Select the most appropriate irradiation diameter for the sample shape: 1 mm diameter for trace foreign matter analysis or...
Open the catalog to page 8Optional Vacuum Measurement Unit and Helium Purge Unit Sensitivity for light elements can be increased by removing atmosphere. Two options are available: a vacuum measurement unit and a helium purge unit. The helium purge unit is effective when measuring liquid samples and samples that generate a gas and cannot be measured in a vacuum. Relative intensity (%) Relative Sensitivity of Measurements with Helium Purging and in Air (sensitivity in vacuum = 100) Profile Comparison in Vacuum and Air (sample: soda-lime glass) Ad vance d H elium Purge Unit (O p tio n) efficiently purges the instrument...
Open the catalog to page 9Comprehensive Quantitation Functions Calibration Curve Method A standard sample is measured and the relationship with the fluorescent X-ray intensity plotted as a calibration curve, which is used for the quantitation of unknown samples Although this method requires selection of a standard sample close to the unknown sample and creation of a calibration curve for each element, it achieves a high level of analysis This method supports all types of corrections for coexistent elements, ncluding absorption/excitation correction and correction for overlapping elements Fundamental Parameter (FP)...
Open the catalog to page 10Func tional De sign L arge Sample Chamber with Small Footprint Installed width is 20% smaller than the previous instrument due to its compact body size. The EDX-7000/8000 can accommodate samples up to a maximum size of W300 x D275 x approx. H100 mm. High -V isibilit y LED L amp When X-rays are generated, an X-ray indicator at the rear of the instrument and an X-RAYS ON lamp at the front turn on, so that the instrument status can be monitored even from a distance. EDX-7000/8000 Energy Dispersive X-Ray Fluorescence Spectrometer
Open the catalog to page 11PCEDX Navi Sof t ware Allow s Eas y Operation from the Star t PCEDX Navi software is designed to simplify X-ray fluorescence spectrometry for beginners, while providing the feature set and capabilities demanded by more experienced users. The straightforward user interface offers intuitive operation and provides a convenient operating environment for beginners and experts alike. Simple Screen Layout Sample image display, analysis conditions selection, and sample name input on the same screen. Collimator Switching from the Measurement Screen Change the collimator diameter while observing the...
Open the catalog to page 12Measurement Setup Screen Results Display Screen Once the measurement is complete, the element names, concentrations, 3a (measurement variance) are displayed, together with the sample image, in an easy-to-understand layout. Display the result list and individual report with a single mouse click. Results List (with images) | Support for Continuous Measurements PCEDX Navi supports measurements using the optional turret. Switch between the sample image screen and sample positioning screen. rement Setup Screen Using the Turret (sample positioning screen) Energy Dispersive X-Ray Fluorescence...
Open the catalog to page 13Functions to Enhance Usability Easy Instrument Startup PCEDX Navi offers instrument initialization and startup (X-ray startup) with simple mouse-click operations After instrument startup, the stabilization function operates for 15 minutes. Analysis and instrument checks are disabled during this period, ensuring that all users collect data in a stable instrument Automatic X-ray Tube Aging When an X-ray tube has not been used for a long period, it requires aging before it can be used again. The software automatically performs the appropriate aging according to the period of non-use Remaining...
Open the catalog to page 14All Shimadzu Europa catalogs and technical brochures
-
TD-30 Series
12 Pages
-
Nexis GC-2030
20 Pages
-
ATX/ATY series
4 Pages
-
MOC63u
6 Pages
-
UHPLC Nexera X2
20 Pages
-
TOC-L
16 Pages
-
RF-6000
24 Pages
-
iMScope Trio
28 Pages
-
ICPE-9800 series
20 Pages
-
UV-3600 Plus
26 Pages
-
Capillary GC-2010 Plus
24 Pages
-
GCMS QP2010 Ultra
24 Pages
-
LCMS-IT-TOF
16 Pages
-
Headspace Sampler HS-20
8 Pages
-
BW-K/BX-K Series
2 Pages
-
Catalog MOC 120H
4 Pages
-
ELB SERIES
2 Pages
-
TW TWC SERIES
8 Pages
-
UW/UX SERIES
4 Pages
-
AUW-D/AUW/AUX/AUY Series
8 Pages
-
Catalog UW-Series
6 Pages
-
Catalog AU-Series
8 Pages
-
MDGC-2010 system
1 Pages
Archived catalogs
-
Catalogue HMV-2 Series
8 Pages
-
TOC-4110
1 Pages
-
Shimadzu FTIR Overview
4 Pages
-
Shimadzu Software Overview
8 Pages
-
Shimadzu GC/GCMS Overview
6 Pages
-
Shimadzu LC/LCMS Overview
12 Pages
-
Shimadzu X-ray Fluorescence
2 Pages