video corpo

MS & TOR Catalog

MS & TOR Catalog
1 / 40 PagesView full catalog

MS & TOR Catalog

Product catalog summary
Overview: The document provides comprehensive details on magnetic contactors and switches, focusing on their specifications, functionalities, and compliance with international standards. It covers various series such as SP, MS, TH, and SD, highlighting their unique features and applications.
Specifications: Detailed specifications are provided for different series, including configurations, energy-saving designs, and compliance with standards like JIS, IEC, UL, and CE. The document outlines rated capacities, control circuit voltages, operational currents, and installation dimensions.
Functionalities: Magnetic contactors are used in switching control systems and motor operations. They feature auxiliary contact blocks for flexibility and composite magnetic switches with thermal overload relays for load protection.
Safety Features: Emphasis is placed on safety through mechanisms like spaced safety partitions and voltage drop withstand designs. The document also notes RoHS compliance by avoiding cadmium in contact materials.
Installation and Usability: Instructions for installation include single unit bases and thermal overload relays with manual/automatic reset options. Guidelines for switching between reset modes are provided.
Type Designation: The type designation system is explained, detailing how models are identified based on features like reversing capability and control circuit voltage.
Technical Data: Tables provide technical data on rated capacities, operation currents, impulse voltages, and contact classes, along with information on electrical and mechanical life.
Procedures: Installation instructions specify correct orientation and mounting types, along with suitable environmental conditions for operation.
Standards and Compliance: Compliance with standards such as IEC 60947-4-1 and UL508 is highlighted, ensuring adherence to safety and performance standards.
Recommendations: Recommendations include using specific models for applications like motor protection in air-conditioning systems and guidelines for adjusting rated currents.
Key Data from Tables: Tables provide data on rated capacities, operational currents, and life expectancy, aiding in model selection for specific applications.
Critical Information: The importance of selecting the correct model based on application requirements and ensuring compliance with standards is emphasized to enhance reliability and performance.
Tripping Characteristics: Tripping characteristic curves illustrate operation time against multiples of rated current, providing insights into overload and phase failure protection.
Reduced Voltage Starting: The λ-Δ starting method is explained, highlighting its benefits in reducing starting current and torque.
Selection Tables: Selection tables for λ-Δ starters and direct on-line starters specify motor rated capacities and contactor selections for different voltage ranges.
Wiring and Symbols: Wiring diagrams and symbol descriptions for components like magnetic contactors and thermal overload relays are included, along with guidelines for setting relay times and selecting breakers.
See more

Catalog excerpts

MS & TOR Catalog-1

Magnetic Contactor/

 Open the catalog to page 1
MS & TOR Catalog-3

Configuration Composite magnetic switch (abbreviated as MS) is comprised of a contactor for switching on and off current and a thermal overload relay for protecting the load. Functions a. Switching the control system for electric power transmission and distribution. b. Operation of the start and stop of motors. c. Electric power control for all kinds of industrial machinery, machine tools, injection molding machines. MAGNETIC SWITCH Functionalities and characteristics of Magnetic Contactor Charact -eristics Other Series Feature a. Products comply with multiple international standards. Compliant...

 Open the catalog to page 3
MS & TOR Catalog-4

MAGNETIC SWITCH c. Increase the reliability of auxiliary contacts (S-P60T and lower). Dual silver contact on movable contact Patterned interface on fixed contact Notes: Apply the above auxiliary terminal design can increase the reliability of the contacts and minimize the contact resistance variation. Charact -eristics Descriptions of product characteristics S-P300S-P400 Category Product features • Energy saving design with low power consumption for operating coils and operating VA capacity. • Operating coils apply common AC/DC power, AC or DC operation, DC holding, absolutely free of electromagnetic...

 Open the catalog to page 4
MS & TOR Catalog-5

Automatic temperature compensation design Bi-metal design can adjust and compensate automatically for ambient temperature changes, which increase the reliability of the product. Single unit installation base can be added for independent use TH-P12, TH-P18 can be installed to single unit installation base, which can be used independently on the track or be fixed on the installation plate. MAGNETIC SWITCH Description of thermal overload relay Safety terminal cover design for high safety level Terminal cover, is easy to install and complies with IEC degree of protection of IP 20. Auxiliary terminal...

 Open the catalog to page 5
MS & TOR Catalog-6

Type designation Type designation Blank Non-reversing Q Control circuit voltage MSO AC Magnetic contactor without enclosure MS i AC Magnetic contactor with enclosure Blank Non-reversing Blank Non- Push button type With Push button type (MSO model is without PB) Q Main circuit voltage EX : 110V - 220V - 380V - 440V (When main circuit voltage and control circuit voltage are the same, it will be blank.) Q Control circuit voltage Q TH heater rated capacity

 Open the catalog to page 6
MS & TOR Catalog-7

Magnetic Contactor / Switch AC control Magnetic Contactor without enclosure with Magnetic enclosure Switch with enclosure (push button) Reversing Nonreversing Standard Thermal overload relay With phase failure protection Rated Capacity Rated impulse voltage (Ui) Contact class Mechanical Life Weight Magnetic Contactor Other Series Selec -tion Auxiliary Contact Electrical Life Rated impulse voltage (Ui) Charact -eristics MAGNETIC SWITCH Mechanical Interlock

 Open the catalog to page 7
MS & TOR Catalog-8

Magnetic Contactor / Switch AC control MAGNETIC SWITCH Nonreversing Reversing with Magnetic enclosure Switch Reversing Nonreversing Standard Thermal overload relay With phase failure Rated Capacity without enclosure Charact -eristics Magnetic Contactor with enclosure (push button) Rated impulse voltage (Ui) Auxiliary Contact Selec -tion Contact class Mechanical Life Magnetic Contactor Electrical Life Rated impulse voltage (Ui) Mechanical Interlock

 Open the catalog to page 8
MS & TOR Catalog-9

MAGNETIC SWITCH Charact -eristics Other Series Selec -tion

 Open the catalog to page 9
MS & TOR Catalog-10

Magnetic Contactor / Switch AC control MAGNETIC SWITCH Nonreversing Reversing with Magnetic enclosure Switch Reversing Nonreversing Rated Capacity Operation current (Ith) Rated impulse voltage (Ui) Auxiliary Contact Selec -tion Contact class Electrical Life Mechanical Life Weight Magnetic Contactor Rated impulse voltage (Ui) Standard Thermal overload relay With phase failure without enclosure Charact -eristics Magnetic Contactor with enclosure (push button) Mechanical Interlock

 Open the catalog to page 10
MS & TOR Catalog-11

MAGNETIC SWITCH Charact -eristics Selec -tion

 Open the catalog to page 11
MS & TOR Catalog-12

Other | SD Series | DC control type Type designation

 Open the catalog to page 12
MS & TOR Catalog-13

Auxiliary contact MAGNETIC SWITCH Magnetic Contactor / Switch DC control Magnetic Contactor Nonreversing Reversing Nonreversing with Magnetic enclosure Switch with enclosure (push button) Reversing Nonreversing Standard Thermal overload relay With phase failure Rated Capacity Control coil voltage Electrical Life Mechanical Life Weight Installation Dimensions (LWH) Other Series Selec -tion Magnetic Contactor Charact -eristics without enclosure Mechanical Interlock

 Open the catalog to page 13
MS & TOR Catalog-14

MAGNETIC SWITCH S-PSC Series Type designation Electromagnetic contactor Charact -eristics Applied to switching capacitor type. Control circult voltage EX110V220V380V440V Other Series Selec -tion Feature: a : applicable to rated voltage AC600V and below, with frequency at 50Hz/60Hz, and applied as a contactor for connecting and disconnecting low-voltage capacitors in parallel. b : contactor is equipped with current limiting resistor, which can suppress surge current output from capacitors when they are initially connected, which could effectively reduce the impact of surge current to the capacitors...

 Open the catalog to page 14
MS & TOR Catalog-15

(time/ hour) Type Rated impulse voltage (Ui) Auxiliary Contact Mechanical Life / Electrical Life (AC-6b) On/ Off Frequency Weight Installation Dimensions (LWH) Charact -eristics Other Series Magnetic Contactor Auxiliary Contact Rated Capacity MAGNETIC SWITCH Capacitor Contactors Selec -tion

 Open the catalog to page 15
MS & TOR Catalog-16

MAGNETIC SWITCH Definite purposes Type designation Definite purposes Charact -eristics close type 1 Pole + conductor contact Code of Coil voltage H Selec -tion Features: All contacts are AMP250 quick contacts , which saves wiring Compact size saving panel space. Standard dimensions of the installation holes, compliant with the installation dimensions of the product of the same grade made by other brands. Comply with Air-conditioning and Refrigeration Institute, USA ARI 780/790 standards. Certified by cUL and compliant with the US UL508 standards. Certified by CSA, compliant with Canadian C.S.A....

 Open the catalog to page 16
MS & TOR Catalog-17

Rated Current w/resistance load (A) Full Rated Current (A) Mechanical / Electrical life ( 10 thousand ) Operation frequency ( time / hour ) MAGNETIC SWITCH Definite Purpose Magnetic Contactor SF Series Start Current(A) (Per Pole) Start Current(A) (Single Phase) (2 Pole) Coil Control Voltage Charact -eristics Other Note: locked rotor current is the rotor current when the motor/compressor rotor is locked/immobilized, i.e. starting current as it is typically named. Applicable scope Applicable to the motor protective system in air-conditioning equipment, refrigerator or the control of the heater,...

 Open the catalog to page 17

All Shihlin Electric & Engineering Corporation catalogs and technical brochures

  1. AC drives

    15  Pages

  2. BHP Catalog

    8  Pages

  3. EMCCB Catalog

    20  Pages

  4. ACB Catalog

    56  Pages

Archived catalogs

  1. ACB/MCCB MCB/MS

    28  Pages

*Prices are pre-tax. They exclude delivery charges and customs duties and do not include additional charges for installation or activation options. Prices are indicative only and may vary by country, with changes to the cost of raw materials and exchange rates.