Low Frequency Online UPS GP9312C 10-100KVA 3Ph in/1Ph out Online UPS special for servers,data center,local network,telecom,medical,industry and so on precision equipments.
6Pages
Catalog excerpts
UPS Power Solutions Expert Rated voltage Rated Frequency 380V three phase 4 wires+G AC Input Voltage Range Frequency Range Power Factor Industial Processes Soft Start Local area Networks Standard screen Bypass Input Voltage range Frequency Range Inverter Bypass Touch screen Output Voltage Accuracy Frequency Accuracy Power Factor <3%(linear load ), <5%(non linear load ) Steady-state response time Overload Capacity Battery Nominal Voltage Float Voltage Shut-off Voltage Charger Current Product snapshot: Sound and light alarm UPS over current、short circuit、under voltage、over temperature Nominal Input Voltage: 380/400/415VAC Output Power Factor: 0.8 Relative humidity : 0-90% Parallel: Maximum 8PCS UPS Battery can be shared in parallel mode Physics Characteristic Weight (KG) High intelligence and reliable power supply: GP9312C/GP9332C provides maximum protection for vital mission-critical networks, security applications (electromedical)and industrial applications thanks to its outstanding mechanical and electrical design. STANDARD: Conform to GB/IEC regulation : EMC:GB7260.2/IEC62040 GB/17626.2~5/IEC61000-4-2~5 Note:Product specifications are subject to change without further notice. The load is powered continuously by the inverter with a filtered, stabilised and regulated sinewave supply. The input and output EMI filters considerably increase the immunity of the load to mains disturbances and surges. The GP9312C/GP9332C uses on-line double conversion technology (VFI) with isolation transformer on theinverter output. The GP9312C/GP9332C is supplied with Watch & Save 3000 software as standard and can be remotely monitored using the Power NetGuard system from anywhere in the world. Additional battery extension packs allow the standard battery runtime to be extended up to several hours.
Open the catalog to page 1Application: Servers Local Area Network (LAN) Data centers Telecommunictions Electro-medical equipment. MINIMUM IMPACT ON SUPPLIES EASY SOURSE: ■Input current distortion <4% for the GP9312C/GP9332C with filter with sinusoidal absorption to remove the risk of resonance with other input supply users or phase shift capacitor sets. The absorbed current distortion is independent of input supply parameters such as impedance. This enable ■ GP9312C/GP9332C to deliver maximum performance levels regardless of the installation environment. With these input features GP9312C/GP9332C can achieve...
Open the catalog to page 2Application: Servers OTHER CHARACTERISTICS: ■0.8 power factor make GP9312C/GP9332C suitable for Local Area Network (LAN) powering ICT and Industrial loads; Data centers Telecommunictions ■High level diagnostics: event log with 128 messages, states,measurements and alarms – available from the Electro-medical equipment. built-in LCD with several languages; MINIMUM IMPACT ON SUPPLIES EASY SOURSE: into the mains supply cause a fault occur. ■BACK FEED protection: to avoid energy feeding back ■Input current distortion <4% for the GP9312C/GP9332C with filter with sinusoidal absorption to remove...
Open the catalog to page 3UPS Power Solutions Expert EXPANDABILITY : GP9312C Series Technical Specifications ■The units can be connected in parallel up to 8 units to increase power availability or redundancy. The single module or the system can be expanded any time to suit power requirements without influencing the initial investment. ■Thanks to the peculiarity of the “Hot System Expansion” feature, the additional unit can be connected in parallel while the other units are on-line and supplying regular power to the load. The new UPS is on-line and will be set up Model Power(kVA) Capacity Voltage range Frequency...
Open the catalog to page 4UPS Power Solutions Expert EXPANDABILITY : GP9312C Series Technical Specifications ■The units can be connected in parallel up to 8 units to increase power availability or redundancy. The single module or the system can be expanded any time to suit power requirements without influencing the initial investment. ■Thanks to the peculiarity of the “Hot System Expansion” feature, the additional unit can be connected in parallel while the other units are on-line and supplying regular power to the load. The new UPS is on-line and will be set up Model Power(kVA) Capacity Voltage range Frequency...
Open the catalog to page 5UPS Power Solutions Expert GP9332C Series Technical Specifications Model Power(kVA) Capacity lnput Rated voltage Voltage range Frequency range Power factor Current harmonic distortion Soft Start Date Center Local area Networks Industrial Processes Bypass Input Rated voltage Permitted voltage range ±15%(selectable from ±10% to ±25% from front panel) Rated frequency Permitted frequency range ±2%(selectable from ±1% to ±5% from front panel) Standard features BackFeed portection; split bypass line Batteries Type Maintenance-free lead-acid VRLA AGM / GEL;NICd Battery Voltage Maximum recharge...