Product Description:
The SCK19 Hall Effect Current Sensor by Shenzhen SoCan Technologies Co., Ltd. is designed based on the Hall effect measurement principle and operates in an open loop circuit mode. It features a high isolation voltage of over 3000VAC between primary and secondary circuits, compact size, and compliance with the UL94-V0 flame retardant rating. The sensor uses a single-chip programmable Hall IC.
Performance:
The sensor can measure DC, AC, pulse, and various irregular waveforms under isolated conditions. It operates at a +5V working voltage, offering fast response speed, low zero drift, low temperature drift, high accuracy, and good linearity. Optimal dynamic performance is achieved when the busbar is fully filled with primary perforations. It also has strong resistance to external electromagnetic interference.
Applications:
The SCK19 sensor is suitable for use in photovoltaic inverters, electric vehicle drivers, battery management systems, and other related products.
Implementation Standards:
The sensor adheres to several standards, including GB/T 7665-2005, JB/T 7490-2007, JB/T 25480-2010, JB/T 9473-2020, and SJ 20792-2000.
Technical Parameters:
  • Input power supply voltage range: +4.5 to +5.5 VDC
  • Current consumption: up to 15 mA
  • Output voltage: 2.5V ±1V to 2.5V ±2V depending on the model
  • Accuracy: ±1% at IPN, TA=25°C
  • Linearity: ±0.5% IPN at RL=10KΩ, TA=25°C
  • Response time: 3 to 5 µs
  • Operating temperature range: -40°C to 125°C
Model Variants:
The SCK19 sensor is available in various models with primary current ratings ranging from 3A to 70A, with corresponding peak values and output voltages.
Notes:
  • Ensure VC accuracy to maintain measurement precision.
  • Primary conductor temperature should not exceed 105°C.
  • Incorrect wiring may damage the sensor.
See more

Catalog excerpts

Socan Open loop current sensor SCK19D Series-1

Hall effect Current Sensor SCK19 Product description Features Based on Hall effect measurement principle, open loop circuit mode. The isolation voltage between primary and secondary is greater than 3000VAC. Easy to install, small size, does not take up space. l Comply with UL94-V0 flame retardant rating. V0 Single-chip programmable Hall IC is adopted. chip Performance: Can measure DC, AC, pulse, and various irregular waveforms under isolated conditions. +5V working voltage, fast response speed, low zero drift, low temperature drift, high accuracy esponse and good linearity. Dynamic performance (di/dt and response time) is optimal when the busbar is fully filled with primary perforations. Strong ability to resist external electromagnetic interference (BCI, EFT, CS, CE, ESD, dv/dt, electromagnetic etc.). Application:  It can be widely used in photovoltaic inverters, electric vehicle drivers, battery management and other products. Implementation standards GB/T 7665-2005 JB/T 7490-2007 JB/T 25480-2010 JB/T 9473-2020 SJ 20792-2000 Certifications Shenzhen SoCan Technologies Co.,Ltd SoCan is committed to continuously improving product quality, and the company reserves the right to update its the products.

 Open the catalog to page 1
Socan Open loop current sensor SCK19D Series-2

Technical Parameters Model Primary Current (A)IPN Primary Current Max. Peak Value (A) IPM Output voltage (V) Vout @±IPN,RL=10KΩ Electrical Data Item Input power supply voltage range Vc Current consumption Ic Withstand resistance RINS @500V DC Output voltage Vout @IPN Output internal resistance ROUT Load Resistance RL Remark 3 Ambient operating temperature TA Ambient storage temperature Ts Input power supply voltage range Vc , Shenzhen SoCan Technologies Co.,Ltd SoCan is committed to continuously improving product quality, and the company reserves the right to update its products. Temperature...

 Open the catalog to page 2
Socan Open loop current sensor SCK19D Series-3

Remark: 1. VC is less than the minimum value, which will lead to inaccurate measurement, VC is greater than the maximum value, which may cause permanent failure of the measurement device. 2. The zero bias voltage and output voltage are linearly related to Vc, so the accuracy of Vc should be ensured as much as possible when applying. Notes: 1. Size error: ±0.5mm; 2. Primary aperture: φ8.4mm; 3. Fixed lead: □ 0.8*0.9mm pitch 12.7mm; 4. Needle output: □0.3*0.5mm pitch 2.54*2mm; 5. The IP indication direction is the positive direction of the current; 6. The temperature of the primary conductor shall...