Socan Open loop current sensor SCK19D Series
3Pages

{{requestButtons}}

Catalog excerpts

Socan Open loop current sensor SCK19D Series - 1

Hall effect Current Sensor SCK19 Product description Features Based on Hall effect measurement principle, open loop circuit mode. The isolation voltage between primary and secondary is greater than 3000VAC. Easy to install, small size, does not take up space. l Comply with UL94-V0 flame retardant rating. V0 Single-chip programmable Hall IC is adopted. chip Performance: Can measure DC, AC, pulse, and various irregular waveforms under isolated conditions. +5V working voltage, fast response speed, low zero drift, low temperature drift, high accuracy esponse and good linearity. Dynamic performance (di/dt and response time) is optimal when the busbar is fully filled with primary perforations. Strong ability to resist external electromagnetic interference (BCI, EFT, CS, CE, ESD, dv/dt, electromagnetic etc.). Application:  It can be widely used in photovoltaic inverters, electric vehicle drivers, battery management and other products. Implementation standards GB/T 7665-2005 JB/T 7490-2007 JB/T 25480-2010 JB/T 9473-2020 SJ 20792-2000 Certifications Shenzhen SoCan Technologies Co.,Ltd SoCan is committed to continuously improving product quality, and the company reserves the right to update its the products.

Open the catalog to page 1
Socan Open loop current sensor SCK19D Series - 2

Technical Parameters Model Primary Current (A)IPN Primary Current Max. Peak Value (A) IPM Output voltage (V) Vout @±IPN,RL=10KΩ Electrical Data Item Input power supply voltage range Vc Current consumption Ic Withstand resistance RINS @500V DC Output voltage Vout @IPN Output internal resistance ROUT Load Resistance RL Remark 3 Ambient operating temperature TA Ambient storage temperature Ts Input power supply voltage range Vc , Shenzhen SoCan Technologies Co.,Ltd SoCan is committed to continuously improving product quality, and the company reserves the right to update its products....

Open the catalog to page 2
Socan Open loop current sensor SCK19D Series - 3

Remark: 1. VC is less than the minimum value, which will lead to inaccurate measurement, VC is greater than the maximum value, which may cause permanent failure of the measurement device. 2. The zero bias voltage and output voltage are linearly related to Vc, so the accuracy of Vc should be ensured as much as possible when applying. Notes: 1. Size error: ±0.5mm; 2. Primary aperture: φ8.4mm; 3. Fixed lead: □ 0.8*0.9mm pitch 12.7mm; 4. Needle output: □0.3*0.5mm pitch 2.54*2mm; 5. The IP indication direction is the positive direction of the current; 6. The temperature of the primary conductor...

Open the catalog to page 3

All Shenzhen Socan Technologies Co. catalogs and technical brochures

  1. SCB12-5A

    1 Pages