Socan Open loop current sensor SCK16 Series
3Pages

{{requestButtons}}

Catalog excerpts

Socan Open loop current sensor SCK16 Series - 1

Hall effect Current Sensor SCK16 Product description Features Based on Hall effect measurement principle, open loop circuit mode. The isolation voltage between primary and secondary is greater than 3000VAC. Comply with UL94-V0 flame retardant rating. Performance It can measure DC, AC, pulse, and various irregular waveform currents of cable conductors under isolation conditions. Wide measurement range, fast response speed, low zero drift, low temperature drift, high accuracy and good linearity. Dynamic performance (di/dt and response time) is optimal when the busbar is fully filled with primary perforations. Strong ability to resist external electromagnetic interference (BCI, EFT, CS, CE, ESD, dv/dt, etc.). Application It can be widely used in inverters, UPS, photovoltaic inverters, electric vehicle drives, high-frequency power supplies, inverter welding machines and other products. Implementation standards GB/T 7665-2005 JB/T 7490-2007 JB/T 25480-2010 JB/T 9473-2020 SJ 20792-2000 Certification Shenzhen SoCan Technologies Co.,Ltd SoCan is committed to continuously improving product quality, and the company reserves the right to update its products. m oc . na c os z s. w w w 1

Open the catalog to page 1
Socan Open loop current sensor SCK16 Series - 2

Technical Parameters Model Parameters (25℃) Primary Current (A)IPN Primary Current Max. Peak Value (A) IPM Output voltage (V) Vout @±IPN, RL=10KΩ Electrical Data Item Output internal resistance ROUT Ambient operating temperature TA Ambient storage temperature Ts Input power supply voltage range Vc Current consumption Ic Withstand resistance RINS @500V DC Output voltage Vout @IPN Temperature Coefficient of Offset Voltage TCVOE Output voltage temperature coefficient TCVout Withstand voltage VD@50Hz,60s,0.1mA Weight m Remarks: Shenzhen SoCan Technologies Co.,Ltd SoCan is committed to...

Open the catalog to page 2
Socan Open loop current sensor SCK16 Series - 3

1. VC is less than the minimum value, which will lead to inaccurate measurement, VC is greater than the maximum value, which may cause permanent failure of the measurement device. 2. When ± 12V50A/uS Notes: 1. Size error: ±1mm; 2. Primary aperture: φ60mm; 3. Fastening hole: φ6mm*2; 4. Output terminal: 2EDGVC-5.08-4P; Mating plug: 2EDGK-5.08-4P; 5. The IP indication direction is the positive direction of the current, OFS is the zero adjustment, and GIN is the output regulation; 6. The temperature of the primary conductor shall not exceed 105°C; 7. Incorrect wiring may cause damage to the...

Open the catalog to page 3

All Shenzhen Socan Technologies Co. catalogs and technical brochures

  1. SCB12-5A

    1 Pages