Specifications:
  • Model: SCM1-10mA
  • Rated Current: ±10mA
  • Measuring Range: ±20mA
  • Output Signal: 485 interface digital quantity (hexadecimal)
  • Operating Voltage: DC80-300V/AC220(10%)
  • Offset Current: 1%
  • Accuracy: <1%
  • Linearity: 1%
  • Offset Temperature Coefficient: 0.2%/℃
  • Response Time: ≤350ms
  • Bus Voltage: 0-300V
  • AC Intrusion Voltage Insulation: 0-250V
  • Insulation Withstand Voltage: 3.5kVDC
  • Quality: 660g
  • Operating Temperature: 0 - +75℃
  • Storage Temperature: -40 - +85℃
  • Dimension: Not specified
Technical Indicators:

These are related to the distributed leakage current system of the SCM1 Series.

Precautions:
  • Ensure correct connection of the insulation detection unit module to the control mother, closed mother, and ground wire to prevent damage.
  • Do not reverse connect A and B of RS485 to avoid communication failure.
  • Ensure A and B of each small current sensor correspond to A and B on the module's terminal block.
  • Connect the mother detection branch from detection branch 1 first, then to the control mother detection branch.
  • In corrosive environments, seal joints, bolts, and lead wires to prevent corrosion and dust.
  • Install and use the sensor without deformation, avoiding heavy objects and heat sources.
See more

Catalog excerpts

SCM1 Series Distributed Insulation Detection Unit-1

Storage temperature Operating temperature quality Rated current ±10mA Measuring range ±20mA output signal 485 interface digital quantity (hexadecimal) Operating Voltage DC80-300V/AC220(10%) Offset current 1% Accuracy <1% Linearity 1% Offset temperature coefficient withstand voltage quality Operating temperature Storage temperature 0.2%/ Response time 350ms bus voltage 0-300V AC intrusion voltage Insulation 0-250V Insulation withstand voltage 3.5kVDC SCM1 Series Technical indicators of distributed leaka

 Open the catalog to page 1
SCM1 Series Distributed Insulation Detection Unit-2

.delaes eb tsum seriw dael dna stlob ,stnioj eht ,tsud dna noisorroc diova ot ,tnemnorivne evisorroc ylereves a nI .2 .rosnes eht ot esolc secruos taeh diova dna ,stcejbo yvaeh diova ,demrofed ton si rosnes eht taht erusne ot esu dna llatsnI .1

 Open the catalog to page 2

All Shenzhen Socan Technologies Co.,Ltd catalogs and technical brochures

  1. SCB12-5A

    1  Page

*Prices are pre-tax. They exclude delivery charges and customs duties and do not include additional charges for installation or activation options. Prices are indicative only and may vary by country, with changes to the cost of raw materials and exchange rates.