SCK18, SCK18A series current sensors 400A..2000A
4Pages

{{requestButtons}}

Catalog excerpts

SCK18, SCK18A series current sensors 400A..2000A - 1

Hall effect Current Sensor SCK18 Product description: 1 Features Based on the Hall effect measurement principle, open loop circuit method. The isolation voltage between primary and secondary is greater than 5000VAC. Designed according to UL94-V0 flame retardant rating. Using automatic adjustment technology, product performance is better. Performance Can measure DC, AC, pulse, and various irregular waveforms under isolated conditions. Wide measurement range, fast response speed, low zero drift, low temperature drift, high accuracy and good linearity. Dynamic performance (di/dt and response time) is optimal when the busbar is fully filled with primary perforations. Strong ability to resist external electromagnetic interference (BCI, EFT, CS, CE, ESD, dv/dt, etc.). Application It can be widely used in inverters, UPS, photovoltaic inverters, electric vehicle drives, high-frequency power supplies, inverter welding machines and other products. Implementation standards GB/T 7665-2005 JB/T 7490-2007 JB/T 25480-2010 JB/T 9473-2020 SJ 20792-2000 Certifications Shenzhen SoCan Technologies Co.,Ltd SoCan is committed to continuously improving product quality, and the company reserves the right to update its products. m oc . na c os z s. w w

Open the catalog to page 1
SCK18, SCK18A series current sensors 400A..2000A - 2

Technical Parameters Model Primary Current 400A (A)IPN Primary Current Max. ±1200A Peak Value (A) IPM Output voltage (V) Vout @±IPN, RL=10KΩ Electrical Data Item Output internal resistance ROUT Load Resistance RL Remark 3 Ambient operating temperature TA Ambient storage temperature Ts Input power supply voltage range Vc Current consumption Ic Withstand resistance RINS @500V DC Output voltage Vout @IPN Temperature Coefficient of Offset Voltage TCVOE Output voltage temperature coefficient TCVout Withstand voltage VD@50Hz,60s,0.1mA Weight m Remarks: 1. If VC is less than the minimum value, the...

Open the catalog to page 2
SCK18, SCK18A series current sensors 400A..2000A - 3

the maximum value, it may cause permanent failure of the measuring device. 2. When ±12V<VCC<±15V,will reduce the measurement range。 Shenzhen SoCan Technologies Co.,Ltd SoCan is committed to continuously improving product quality, and the company reserves the right to update its products.

Open the catalog to page 3
SCK18, SCK18A series current sensors 400A..2000A - 4

Notes: 1. Size error: ±1mm; 2. Primary aperture: □40*30mm; 3. Fastening hole: φ4.5mm*2; 4. The output terminal of SCK18 Series is 2501P04V00A; The output terminals of SCK18A is JST B4B-XH-A. 5. The IP indication direction is the positive direction of the current; 6. The temperature of the primary conductor shall not exceed 105°C; Shenzhen SoCan Technologies Co.,Ltd SoCan is committed to continuously improving product quality, and the company reserves the right to update its products. m oc . na c os z s. w w

Open the catalog to page 4

All Shenzhen Socan Technologies Co. catalogs and technical brochures

  1. SCB12-5A

    1 Pages