  • Model Variants: SCD50-10mA, SCD50-20mA, SCD50-50mA
  • Rated Current: ±10mA, ±20mA, ±50mA
  • Measuring Range: 0~±20mA, 0~±40mA, 0~±100mA
  • Diameter: Φ18mm
  • Output Interface: 485 interface, Digital output (hexadecimal)
  • Baud Rate: 9600bps
  • Working Voltage: +12V (±5%) (9-30V adjustable)
  • Accuracy Level: 1%
  • Linearity Level: 1%
  • Response Time: ≤60ms
  • Temperature Drift Characteristics: 500ppm/℃
  • Insulation Voltage: ≤3000V DC
  • Current Consumption: ≤11mA
  • Weight: 70g
  • Working Temperature Range: -25℃~ +85℃
  • Storage Temperature Range: -25℃~ +85℃
Precautions
  • Ensure the product is calibrated for zero point and accuracy before use. Contact the manufacturer for on-site adjustments.
  • Do not alter or remove any stickers on the product.
  • Verify the number, model, and specifications against the packing list before use.
  • Connect signal input, output, and auxiliary power supply wiring according to the reference diagram for the selected product type.
  • Ensure auxiliary power accuracy is not less than 4%, with ripple Vpp ≤ 0.4%.
  • The environment should be free of conductive dust and corrosive gases.
  • In strong magnetic interference environments, shield the input line and sensing hole, and keep the output line short. Maintain installation spacing of ≥10mm for centralized installations.
See more

Catalog excerpts

SCD50 Series Digitial Current Sensor with RS485 output signal-1

Digital leakage current sensor specifications SCD50 Series SCD50-20mA Storage temperature range Working temperature range Rated current Measuring range Diameter(mm) Output Interface Baud rate Working voltage Accuracy level Linearity level Response time Temperature drift characteristics Insulation voltage Current consumption Weight Model Specifications Precautions 1. Check and confirm the number, model and specifications according to the packing list before usage. 2. Connect the signal input, output and auxiliary power supply wiring according to the wiring reference diagram corresponding to the selected product type. After checking the error, reconnect the auxiliary power supply. 3. Auxiliary power requirements: Accuracy not less than 4%, ripple Vpp 0.4%. 4. The environment should be free of conductive dust and corrosive gases that may destroy insulation and metals. 5. When using the meter pen to measure the output signal of the product, turn the terminal screw to the end first. 6. When the product is used in a strong magnetic interference environment, please shield the input line and the sensing hole. The output line should be as short as possible. For centralized installation, installation spacing 10mm. 7. The product has been calibrated well for zero point and accuracy before shipment. Please do not adjust it by yourself. When you really need on-site adjustment, please contact us. 8. Do not al

 Open the catalog to page 1

All Shenzhen Socan Technologies Co.,Ltd catalogs and technical brochures

  1. SCB12-5A

    1  Page

*Prices are pre-tax. They exclude delivery charges and customs duties and do not include additional charges for installation or activation options. Prices are indicative only and may vary by country, with changes to the cost of raw materials and exchange rates.