The SCY13 series by Shenzhen SoCan Technologies Co., Ltd is a split core Hall effect current sensor designed for easy installation without disassembling the busbar. It operates on the Hall effect measurement principle in an open loop circuit mode and provides high isolation voltage (>3000VAC) between primary and secondary circuits. The sensor is compliant with UL94-V0 flame retardant rating and uses automotive-specific lead connector output.

Performance Features:
The sensor can measure DC, AC, pulse, and various irregular waveform currents under isolation conditions. It offers a wide measurement range, fast response speed, low zero and temperature drift, high accuracy, and good linearity. The dynamic performance is optimal when the busbar is fully filled with primary perforations. It also has strong resistance to external electromagnetic interference.

Applications:
The SCY13 series is suitable for use in communication power supplies, UPS systems, photovoltaic inverters, electric vehicle drives, and other products.

Implementation Standards:
The product adheres to several standards including GB/T 7665-2005, JB/T 7490-2007, JB/T 25480-2010, JB/T 9473-2020, and SJ 20792-2000.

Technical Parameters:
  • Input power supply voltage range: ±5 VDC
  • Current consumption: up to ±20 mA
  • Withstand resistance: ≥1000 MΩ at 500V DC
  • Output voltage: Varies with model and conditions
  • Accuracy: ±1%
  • Linearity: ±1% IPN
  • Offset voltage: ±10 to ±30 mV
  • Response time: 3 to 5 µs
  • Operating temperature: -40 to 125°C
  • Storage temperature: -40 to 125°C
  • Withstand voltage: 3000 VAC
  • Weight: 80 g

Model Variants:
The SCY13 series includes models SCY13, SCY13A, SCY13B, and SCY13C, each with different primary current ratings and output voltage specifications.

Dimensions and Installation Notes:
The sensors have a primary aperture of φ24mm and specific wire shell and terminal configurations for each model. Incorrect wiring can damage the sensor, and the IP indication direction is the positive direction of the current.
See more

Catalog excerpts

Open-loop Hall effect current sensor with harness/ AC / DC, Split core ø24mm, SCY13 Series-1

Split Core Hall effect Current Sensor SCY13 SCY13, SCY Y13A, SCY13C, SCY1 13B Product description Features Based on Hall effect measurement principle, open loop circuit mode. The isolation voltage between primary and secondary is greater than 3000VAC. Can be opened and closed up and down, no need to disassemble the busbar, easy to install. Comply with UL94-V0 flame retardant rating. V0 Use automotive-specific lead connector output specific Performance It can measure DC, AC, pulse, and various irregular waveform currents of cable conductors waveform under isolation conditions. Wide measurement range, fast response speed, low zero drift, low temperature drift, high accuracy and good linearity. Dynamic performance (di/dt and response time) is optimal when the busbar i fully filled with is primary perforations. Strong ability to resist external electromagnetic interference (BCI, EFT, CS, CE, ESD, dv/dt, etc.). Application It can be widely used in communication power supply, UPS, photovoltaic inverter, electric vehicle drive and other products. Implementation standards GB/T 7665-2005 JB/T 7490-2007 JB/T 25480-2010 JB/T 9473-2020 SJ 20792-2000 Certification Shenzhen SoCan Technologies Co.,Ltd SoCan is committed to continuously improving product quality, and the company reserves the right to update its the products. www.szsocan.com 1

 Open the catalog to page 1
Open-loop Hall effect current sensor with harness/ AC / DC, Split core ø24mm, SCY13 Series-2

Technical Parameters Model Primary Current (A)IPN Primary Current Max. Peak Value (A) IPM Output voltage (V) Vout @±IPN,RL=25KΩ Electrical Data Item Input power supply voltage range Vc Withstand resistance RINS @500V DC Output voltage Vout @IPN Output internal resistance ROUT Load Resistance RL Remark 3 Ambient operating temperature TA Ambient storage temperature Ts Response time tD @ 0→IPN (Remark 4) Withstand voltage VD@50Hz,60s,0.1mA Weight m Temperature Coefficient of Offset Voltage TCVOE Output voltage temperature coefficient Shenzhen SoCan Technologies Co.,Ltd SoCan is committed to continuously...

 Open the catalog to page 2
Open-loop Hall effect current sensor with harness/ AC / DC, Split core ø24mm, SCY13 Series-3

Shenzhen SoCan Technologies Co.,Ltd SoCan is committed to continuously improving product quality, and the company reserves the right to update its products. www.szsocan.com 3

 Open the catalog to page 3
Open-loop Hall effect current sensor with harness/ AC / DC, Split core ø24mm, SCY13 Series-4

Concentrate: 1. Size error: ±0.5mm; 2. Primary aperture: φ24mm; 3. SCY13 wire rubber shell: 04T-JWPT-VSLE-S/JST, Terminal: SWPT-001T-P025/JST; 4. SCY13A wire shell: 2520H-04/ECI, Terminal: 2521-2/ECI; 5. The IP indication direction is the positive direction of the current; 6. Incorrect wiring may cause damage to the sensor. Shenzhen SoCan Technologies Co.,Ltd SoCan is committed to continuously improving product quality, and the company reserves the right to update its products. www.szsocan.com 4

 Open the catalog to page 4
Open-loop Hall effect current sensor with harness/ AC / DC, Split core ø24mm, SCY13 Series-5

Technical Parameters Model Primary Current (A)IPN Primary Current Max. Peak Value (A) IPM Output Voltage (V) Vout @±IPN,RL=25KΩ Electrical Data Item Input power supply voltage range Vc Withstand resistance RINS @500V DC Output voltage Vout @IPN Output internal resistance ROUT Load Resistance RL Remark 3 Ambient operating temperature TA Ambient storage temperature Ts Response time tD @ 0→IPN (Remark 4) Withstand voltage VD@50Hz,60s,0.1mA Weight m Temperature Coefficient of Offset Voltage TCVOE Output voltage temperature coefficient Shenzhen SoCan Technologies Co.,Ltd SoCan is committed to continuously...

 Open the catalog to page 5
Open-loop Hall effect current sensor with harness/ AC / DC, Split core ø24mm, SCY13 Series-6

Shenzhen SoCan Technologies Co.,Ltd SoCan is committed to continuously improving product quality, and the company reserves the right to update its products. www.szsocan.com 6

 Open the catalog to page 6
Open-loop Hall effect current sensor with harness/ AC / DC, Split core ø24mm, SCY13 Series-7

Notes: 1. Size error: ±0.5mm; 2. Primary aperture: φ24mm; 3. SCY13C wire shell: 04T-JWPT-VSLE-S/JST, Terminal: SWPT-001T-P025/JST; 4. SCY13B wire shell: 2520H-04/ECI, Terminal: 2521-2/ECI; 5. The IP indication direction is the positive direction of the current; 6. Incorrect wiring may cause damage to the sensor. Shenzhen SoCan Technologies Co.,Ltd SoCan is committed to continuously improving product quality, and the company reserves the right to update its products. www.szsocan.com 7