Product Description:
The SCK4 series is based on the Hall effect measurement principle and operates in an open-loop circuit mode. It features a high isolation voltage between primary and secondary circuits, exceeding 3000VAC, and complies with the UL94-V0 flame retardant rating.
Performance:
The sensor can measure DC, AC, pulse, and various irregular waveforms under isolated conditions. It offers a wide measurement range, fast response speed, low temperature drift, high accuracy, and good linearity. Optimal dynamic performance is achieved when the busbar is fully filled with primary perforations. It also has strong resistance to external electromagnetic interference.
Applications:
The SCK4 series is suitable for use in inverters, UPS, photovoltaic inverters, electric vehicle drives, high-frequency power supplies, and inverter welding machines.
Implementation Standards:
The product complies with several standards, including GB/T 7665-2005, JB/T 7490-2007, JB/T 25480-2010, JB/T 9473-2020, and SJ 20792-2000.
Technical Parameters:
The SCK4 series offers various models with primary current ratings from 300A to 2000A. The maximum peak value for primary current ranges from ±900A to ±2400A. The output voltage is ±4V with a 1% tolerance. The input power supply voltage range is ±11V to ±18V, with a current consumption of up to 20mA. The sensor has a withstand resistance of 1000 MΩ at 500V DC and an output internal resistance of 102 Ω. The accuracy is ±1%, and linearity is ±0.5% IPN. The response time is between 3 to 5 microseconds.
Dimensions and Notes:
The SCK4 series dimensions include a primary aperture of 41.6mm x 12mm and fastening holes of φ4.5mm. The output terminals differ between models, with SCK4 using Molex 5045-04AG and SCK4A using JST B4B-XH-A. The primary conductor temperature should not exceed 105°C, and incorrect wiring may damage the sensor.
See more

Catalog excerpts

Open-loop Hall effect current sensor / AC / DC 41*12mm, 500..2000 A | SCK4 series-1

Hall effect Open-loop current sensor loop SCK4 Product description Features Based on Hall effect measurement principle, open loop circuit mode. The isolation voltage between primary and secondary is greater than 3000VAC. Comply with UL94-V0 flame retardant rating. V0 Performance Can measure DC, AC, pulse, and various irregular waveforms under isolated conditions. Wide measurement range, fast response speed, low zero drift, low temperature drift, high accuracy and good linearity. Dynamic performance (di/dt and response time) is optimal when the busbar is fully filled with primary perforations. Strong ability to resist external electromagnetic interference (BCI, EFT, CS, CE, ESD, dv/dt, etc.). Application: It can be widely used in inverters, UPS, photovoltaic inverters, electric vehicle drives, high-frequency power supplies, inverter welding machines and other products. frequency Shenzhen SoCan Technologies Co.,Ltd SoCan is committed to continuously improving product quality, and the company reserves the right to update its products.

 Open the catalog to page 1
Open-loop Hall effect current sensor / AC / DC 41*12mm, 500..2000 A | SCK4 series-2

Technical Parameters Model Primary Current Max. Peak Value IPM ±900A ±1500A ±1800A ±2400A ±2400A ±2400A ±2400A Output voltage Vout @±IPN,RL=10KΩ Electrical Data Item Input power supply voltage range Vc Output internal resistance ROUT Load Resistance RL Remark 3 Ambient operating temperature TA Ambient storage temperature Ts Withstand resistance RINS @500V DC Output voltage Vout @IPN Temperature Coefficient of Offset Voltage TCVOE Output voltage temperature coefficient TCVout Response time If VC is less than the minimum value, the measurement will be inaccurate. If VC is greater than the maximum...

 Open the catalog to page 2
Open-loop Hall effect current sensor / AC / DC 41*12mm, 500..2000 A | SCK4 series-3

When ±12V VCC ±15V will reduce the measurement range. Shenzhen SoCan Technologies Co.,Ltd SoCan is committed to continuously improving product quality, and the company reserves the right to update its products.

 Open the catalog to page 3
Open-loop Hall effect current sensor / AC / DC 41*12mm, 500..2000 A | SCK4 series-4

Notes: 1. Size error: ±1mm; 2. Primary aperture: □ 41.6*12mm; 3. Fastening hole: φ4.5mm*2; 4. SCK4 output terminal: Molex 5045-04AG; SCK4A output terminal: JST B4B-XH-A 5. The IP indication direction is the positive direction of the current; 6. The temperature of the primary conductor shall not exceed 105°C; 7. Incorrect wiring may cause damage to the sensor. Shenzhen SoCan Technologies Co.,Ltd SoCan is committed to continuously improving product quality, and the company reserves the right to update its products.