Open-loop Hall effect current sensor / AC / DC 41*12mm, 500..2000 A | SCK4 series
4Pages

{{requestButtons}}

Catalog excerpts

Open-loop Hall effect current sensor / AC / DC 41*12mm, 500..2000 A | SCK4 series - 1

Hall effect Open-loop current sensor loop SCK4 Product description Features Based on Hall effect measurement principle, open loop circuit mode. The isolation voltage between primary and secondary is greater than 3000VAC. Comply with UL94-V0 flame retardant rating. V0 Performance Can measure DC, AC, pulse, and various irregular waveforms under isolated conditions. Wide measurement range, fast response speed, low zero drift, low temperature drift, high accuracy and good linearity. Dynamic performance (di/dt and response time) is optimal when the busbar is fully filled with primary perforations. Strong ability to resist external electromagnetic interference (BCI, EFT, CS, CE, ESD, dv/dt, etc.). Application: It can be widely used in inverters, UPS, photovoltaic inverters, electric vehicle drives, high-frequency power supplies, inverter welding machines and other products. frequency Shenzhen SoCan Technologies Co.,Ltd SoCan is committed to continuously improving product quality, and the company reserves the right to update its products.

Open the catalog to page 1
Open-loop Hall effect current sensor / AC / DC 41*12mm, 500..2000 A | SCK4 series - 2

Technical Parameters Model Primary Current Max. Peak Value IPM ±900A ±1500A ±1800A ±2400A ±2400A ±2400A ±2400A Output voltage Vout @±IPN,RL=10KΩ Electrical Data Item Input power supply voltage range Vc Output internal resistance ROUT Load Resistance RL Remark 3 Ambient operating temperature TA Ambient storage temperature Ts Withstand resistance RINS @500V DC Output voltage Vout @IPN Temperature Coefficient of Offset Voltage TCVOE Output voltage temperature coefficient TCVout Response time If VC is less than the minimum value, the measurement will be inaccurate. If VC is greater than the...

Open the catalog to page 2
Open-loop Hall effect current sensor / AC / DC 41*12mm, 500..2000 A | SCK4 series - 3

When ±12V VCC ±15V will reduce the measurement range. Shenzhen SoCan Technologies Co.,Ltd SoCan is committed to continuously improving product quality, and the company reserves the right to update its products.

Open the catalog to page 3
Open-loop Hall effect current sensor / AC / DC 41*12mm, 500..2000 A | SCK4 series - 4

Notes: 1. Size error: ±1mm; 2. Primary aperture: □ 41.6*12mm; 3. Fastening hole: φ4.5mm*2; 4. SCK4 output terminal: Molex 5045-04AG; SCK4A output terminal: JST B4B-XH-A 5. The IP indication direction is the positive direction of the current; 6. The temperature of the primary conductor shall not exceed 105°C; 7. Incorrect wiring may cause damage to the sensor. Shenzhen SoCan Technologies Co.,Ltd SoCan is committed to continuously improving product quality, and the company reserves the right to update its products.

Open the catalog to page 4