Product Description: The Hall effect current sensors SCB11 and SCB11R by Shenzhen SoCan Technologies Co., Ltd are designed based on the Hall effect measurement principle and operate in a closed-loop circuit mode. They offer an isolation voltage greater than 3000VAC and comply with the UL94-V0 flame retardant rating.
Features: These sensors can measure DC, AC, pulse, and various irregular waveform currents under isolation conditions. They exhibit very low temperature and zero drift, fast response time, and good linearity with accuracy up to 0.1%. They are optimized for dynamic performance when the busbar is fully filled with primary perforations and have strong resistance to external electromagnetic interference.
Applications: The sensors are suitable for use in inverters, UPS, photovoltaic inverters, electric vehicle drives, high-frequency power supplies, and inverter welding machines.
Implementation Standards: The sensors adhere to several standards including GB/T 7665-2005, JB/T 7490-2007, JB/T 25480-2010, JB/T 9473-2020, and SJ 20792-2000.
Technical Parameters: The document provides detailed technical parameters for models SCB11T and SCB11VT/SCB11R, including primary current ratings, turns ratio, secondary coil resistance, output signal, and electrical data such as input power supply voltage range, current consumption, accuracy, linearity, offset current, response time, bandwidth, and operating temperatures. The sensors have a withstand voltage of 3000 VAC and weigh 110 grams.
Dimensions and Notes: The document includes dimensions for the SCB11T, SCB11VT, and SCB11R models, with notes on size error, primary aperture, fastening holes, output terminals, and the importance of correct wiring to avoid sensor damage.
Hall effect Current Sensor Features • Based on Hall effect measurement principle, close loop circuit mode. • The isolation voltage between primary and secondary is greater than 3000VAC. • Comply with UL94-V0 flame retardant rating. • It can measure DC, AC, pulse, and various irregular waveform currents of cable conductors under isolation conditions. • Very low temperature drift, zero drift, fast response time, good linearity, accuracy can reach 0.1%. • Dynamic performance (di/dt and response time) is optimal when the busbar is fully filled with primary perforations. • Strong ability to resist external electromagnetic interference (BCI, EFT, CS, CE, ESD, dv/dt, etc.). • It can be widely used in inverters, UPS, photovoltaic inverters, electric vehicle drives, high-frequency power supplies, inverter welding machines and other products.
Open the catalog to page 11. VC is greater than the maximum value, which may cause permanent failure of the measurement Shenzhen SoCan Technologies Co.,Ltd SoCan is committed to continuously improving product quality, and the company reserves the right to update its products.
Open the catalog to page 23. Follow speed di/dt> 100A/uS 5. The IP indication direction is the positive direction of the current; 6. Incorrect wiring may cause damage to the sensor. Shenzhen SoCan Technologies Co.,Ltd SoCan is committed to continuously improving product quality, and the company reserves the right to update its products.
Open the catalog to page 31. VC is greater than the maximum value, which may cause permanent failure of the measurement device. Shenzhen SoCan Technologies Co.,Ltd SoCan is committed to continuously improving product quality, and the company reserves the right to update its products.
Open the catalog to page 4SCB11R(Voltage output) Dimension (in mm): Shenzhen SoCan Technologies Co.,Ltd SoCan is committed to continuously improving product quality, and the company reserves the right to update its products.
Open the catalog to page 55. The IP indication direction is the positive direction of the current; 6. Incorrect wiring may cause damage to the sensor. Shenzhen SoCan Technologies Co.,Ltd SoCan is committed to continuously improving product quality, and the company reserves the right to update its products.
Open the catalog to page 640 Pages
3 Pages
3 Pages