Closed-loop current sensor / DC / leakage current SCD2 Series
3Pages

{{requestButtons}}

Catalog excerpts

Closed-loop current sensor / DC / leakage current SCD2 Series - 1

DC Leakage Current Sensor SCD2 Product description Features  SCD series DC leakage current sensor, using the principle of magnetic modulation closed-loop, for isolated measurement of DC milliampere small current.  The isolation voltage between primary and secondary is greater than 3000VAC.  Temperature compensation circuit control, zero drift, accurate measurement.  Perforated input, unplugging terminals, screw fastening flat mounting.  Overall size(mm):99(L)×23.5(W)×108(H); Aperture: 40mm.  Comply with UL94-V0 flame retardant rating. Applications  Widely used in emerging industries and fields such as electric power, industrial automation, solar photovoltaic, etc. Implementation standards: GB/T 7665-2005 JB/T 25480-2010 JB/T 11205-2011 SJ 20790-2000 Certification: Shenzhen SoCan Technologies Co.,Ltd SoCan is committed to continuously improving product quality, and the company reserves the right to update its products.

Open the catalog to page 1
Closed-loop current sensor / DC / leakage current SCD2 Series - 2

Technical Parameters Model Parameters (25℃) Primary Current IPN (DC) Primary Current Max. Peak Value IPM(DC) Output voltage Vout @±IPN,RL=10KΩ Electrical Data Item Input power supply voltage range Vc(±5%)(Remark 1) Output internal resistance ROUT Temperature coefficient of offset voltage TCVOE Current consumption Ic Withstand resistance RINS @500V DC Output voltage Vout @IPN, RL=10KΩ,TA= 25℃ Operating ambient temperature range TA Storage ambient temperature range Ts Insulation withstand voltage VD@50Hz, 60s, 0.1mA Weight m Remark: Shenzhen SoCan Technologies Co.,Ltd SoCan is committed to...

Open the catalog to page 2
Closed-loop current sensor / DC / leakage current SCD2 Series - 3

If VC is less than the minimum value, the measurement will be inaccurate. If VC is greater than the maximum value, it may cause permanent failure of the measuring device. 2. When ±12V<VCC<±15V,will reduce the measurement range 3. VOUT = 5.05 * Notes: 1. Size error: ±1mm; 2. Primary aperture: φ40mm; 3. Fastening hole: φ6mm*2; 4. Output terminal: 2EDGVC-5.08-4P; 5. The IP indication direction is the positive direction of the current, and the OFS is the zero adjustment; 6. Incorrect wiring may cause damage to the sensor; 7. The zero voltage of the sensor can be adjusted appropriately according...

Open the catalog to page 3

All Shenzhen Socan Technologies Co. catalogs and technical brochures

  1. SCB12-5A

    1 Pages