DC Leakage Current Sensor SCD1 Product description Features SCD series DC leakage current sensor, using the principle of magnetic modulation closed closed-loop, for isolated measurement of DC milliampere small current. The isolation voltage between primary and secondary is greater than 3000VAC. Temperature compensation circuit control, zero drift, accurate measurement. ion Perforated input, unplugging terminals, screw fastening flat mounting. Overall size(mm): 72(L)×18(W)×60(H) 72(L)×18(W)×60(H);Aperture:18mm Comply with UL94-V0 flame retardant rating. V0 Applications Widely used in emerging industries and fields such as electric power, industrial automation, solar photovoltaic, etc. Implementation standards: GB/T 7665-2005 JB/T 25480-2010 JB/T 11205-2011 SJ 20790-2000 Shenzhen SoCan Technologies Co.,Ltd SoCan is committed to continuously improving product quality, and the company reserves the right to update its products. www.szsocan.com 1/3 sales@

Open the catalog to page 1
Closed-loop current sensor / DC / leakage current SCD1 Series - 2

Technical Parameters Model Parameters (25℃) Primary Current IPN (DC) Primary Current Max. Peak Value IPM(DC) Output voltage Vout @±IPN,RL=10KΩ Output internal resistance ROUT Temperature coefficient of offset voltage TCVOE Current consumption Ic Withstand resistance RINS @500V DC @IPN Output voltage Vout RL=10KΩ TA= 25 Operating ambient temperature range TA Storage ambient temperature range Ts Insulation withstand voltage VD@50Hz, 60s, 0.1mA Weight m Input power supply voltage range Vc Remark: Shenzhen SoCan Technologies Co.,Ltd SoCan is committed to continuously improving product quality,...

Open the catalog to page 2
Closed-loop current sensor / DC / leakage current SCD1 Series - 3

If VC is less than the minimum value, the measurement will be inaccurate. If VC is greater than the maximum value, it may cause permanent failure of the measuring device. Notes: 1. Size error: ±0.5mm; 2. Primary aperture: φ18mm; 3. Fastening hole: ○ 4.2*3.6mm*2; 4. Output terminal: 2EDGVC-5.08-4P; 5. The IP indication direction is the positive direction of the current, and the OFS is the zero adjustment; 6. Incorrect wiring may cause damage to the sensor; 7. The zero voltage of the sensor can be adjusted appropriately according to the needs of users; Shenzhen SoCan Technologies Co.,Ltd...

Open the catalog to page 3

All Shenzhen Socan Technologies Co. catalogs and technical brochures

  1. SCB12-5A

    1 Pages