1. Catalogs
  2. Shenzhen Socan Technologies Co.,Ltd
  3. Closed-loop current sensor / DC /AC PCB Mount Hall current Sensor SCB2 Series

Closed-loop current sensor / DC /AC PCB Mount Hall current Sensor SCB2 Series

Closed-loop current sensor / DC /AC PCB Mount Hall current Sensor SCB2 Series

Closed-loop current sensor / DC /AC PCB Mount Hall current Sensor SCB2 Series

Product catalog summary
Product Description:
The SCB2 Hall Effect Current Sensor by Shenzhen SoCan Technologies Co., Ltd is designed based on the Hall effect measurement principle and operates in a closed-loop circuit mode. It offers an isolation voltage greater than 3000VAC and complies with the UL94-V0 flame retardant rating.

Performance:
The sensor can measure DC, AC, pulse, and various irregular waveform currents under isolation conditions. It features very low temperature drift, fast response time, good linearity, and accuracy up to 0.1%. It also has strong resistance to external electromagnetic interference.

Applications:
This sensor is suitable for use in inverters, UPS, photovoltaic inverters, electric vehicle drives, high-frequency power supplies, and inverter welding machines.

Implementation Standards:
The product adheres to several standards including GB/T 7665-2005, JB/T 7490-2007, JB/T 25480-2010, JB/T 9473-2020, and SJ 20792-2000.

Technical Parameters:
The SCB2 model is available in variations for 5mA and 10mA primary currents, with a maximum peak value of ±10mA and ±20mA respectively. It has a turns ratio of 1000:5000 or 1000:2500, and secondary coil internal resistance of 710Ω or 310Ω at 70℃. The output signal is ±25mA, and the measure resistance is between 100 to 200Ω.

Electrical Data:
The input power supply voltage range is ±12 to ±18 VDC, with a current consumption of 13mA plus output current. Accuracy is up to ±0.8%, and linearity is up to ±0.5%. The response time is 1 microsecond, and it operates within an ambient temperature range of -40 to 85℃.

Notes:
Ensure correct installation and wiring to avoid damage. The sensor measures AC and DC voltage by measuring milliampere current. Proper calculation of current limiting resistance is necessary before use.
See more

Catalog excerpts

Closed-loop current sensor / DC /AC PCB Mount Hall current Sensor SCB2 Series-1

Hall effect Current Sensor SCB2 Product description Features Based on Hall effect measurement principle, close loop circuit mode. The isolation voltage between primary and secondary is greater than 3000VAC. Comply with UL94-V0 flame retardant rating. V0 Performance It can measure DC, AC, pulse, and various irregular waveform currents of cable conductors under isolation conditions. Very low temperature drift, zero drift, fast response time, good linearity, accuracy can reach 0.1%. Dynamic performance (di/dt and response time) is optimal when the busbar is fully filled with primary perforations. Strong ability to resist external electromagnetic interference (BCI, EFT CS, CE, ESD, dv/dt, EFT, etc.). Application It can be widely used in inverters, UPS, photovoltaic inverters, electric vehicle drives, high-frequency power supplies, inverter welding machines and other products. frequency Implementation standards GB/T 7665-2005 JB/T 7490-2007 JB/T 25480-2010 JB/T 9473-2020 SJ 20792-2000 Certification Shenzhen SoCan Technologies Co.,Ltd SoCan is committed to continuously improving product quality, and the company reserves the right to update its the products. m oc . na c os z s. w w w 1

 Open the catalog to page 1
Closed-loop current sensor / DC /AC PCB Mount Hall current Sensor SCB2 Series-2

Parameters(25℃) Primary Current (A)IPN Primary Current Max. Peak Value (A) IPM Turns ratio KN Secondary coil internal resistance RS @TA=70℃ Output signal ISN @IPN,(Remark 2) Measure resistance RM @IPN,Vc=±15V, Electrical Data Item Input power supply voltage range Vc (±5%)(Remark 1) Ambient operating temperature TA Ambient storage temperature Ts Offset current IOE @TA= 25℃,IP=0 Magnetic offset current IOM @ IP→0 Temperature coefficient of offset current TCIOE Response time tD @ 0→IPN Withstand voltage VD@50Hz,60s,0.1mA Weight m Remarks: 1. VC is greater than the maximum value, which may cause...

 Open the catalog to page 2
Closed-loop current sensor / DC /AC PCB Mount Hall current Sensor SCB2 Series-3

measurement device. Notes: 1. Size error: ±0.5mm; 2. Lead size: □ 0.64*0.64mm*5, recommended PCB cut-out φ1.2mm; 3. This sensor is used to measure AC and DC voltage by measuring milliampere current; 4. Before use, calculate the current limiting resistance R0 resistance and resistance power between voltages; 5. The installation size should be consistent with the sensor size, and the pins should not be squeezed to avoid an open circuit of the internal pin connection; 6. When performing pin welding, the soldering time should be as short as possible to avoid causing the internal pin connection to...

 Open the catalog to page 3

All Shenzhen Socan Technologies Co.,Ltd catalogs and technical brochures

  1. SCB12-5A

    1  Page

*Prices are pre-tax. They exclude delivery charges and customs duties and do not include additional charges for installation or activation options. Prices are indicative only and may vary by country, with changes to the cost of raw materials and exchange rates.