1. Catalogs
  2. Shenzhen Sikes Electric Co., Ltd.
  3. sikes harmoic power filter for 90kw ABB VFD INVERTER THDI

sikes harmoic power filter for 90kw ABB VFD INVERTER THDI

sikes harmoic power filter for  90kw ABB  VFD INVERTER  THDI

sikes harmoic power filter for 90kw ABB VFD INVERTER THDI

Product catalog summary
Technical Specifications:
The document outlines the technical specifications for the PHF Harmonic Filter, designed to work with Danfoss VLT® Series drives. It includes details on rated current, voltage, frequency, and system requirements. The filter is designed for a symmetrical load of a converter with an uncontrolled B6 rectifier.

Key Specifications:
  • Rated Voltage: 400V, Voltage Range: 380~415V
  • Rated Frequency: 50Hz
  • Overrating Capacity: 160% for 60 seconds once per hour
  • Efficiency: >0.98, Noise: <72db
  • Insulation Resistance: >100MΩ (1000VDC)
  • Protection Class: IP 20

Standards and Compliance:
The filter complies with IEEE 519, EN 61000-2-2, EN 61000-2-4, IEC/EN 61000-3-2, IEC/EN 61000-3-4, and IEC/EN 61000-3-12 standards. It is important to observe the protection clause to ISO 16016.

Performance and Installation:
The document provides typical performance data at nominal and full load ranges, highlighting the power factor and THD(i) across different load percentages. Installation instructions specify connections to the grid and VFD sides, with options for bypassing capacitors to improve power factor.

Dimensions and Mounting:
Details on dimensions and mounting are provided, with a note that technical specifications in the drawing are without obligation and subject to change.

Additional Notes:
General tolerances conform to DIN 7168-m, and the document includes a disclaimer regarding the accuracy of technical specifications.
See more

Catalog excerpts

sikes harmoic power filter for  90kw ABB  VFD INVERTER  THDI -1

产品系列号/ Model family: PHF 005 Designed for matched performance with Danfoss VLT® Series drives 专为匹配 Danfoss VLT® 系列变频器的性能而设计 / TECHNICAL DATA Rated voltage Rated frequency System requirements Rated current Overrating capacity Test voltage Insulation Class Insulation resistance THVD < 2%, line voltage unbalance < 1% (THVD<2%线电压不平衡率<1%) 90 Symmetrical load of a converter with uncontrolled B6 rectier.(带有6脉波整流桥的⾮线性逆变器负载) at nominal load 在满载条件下 / TECHNICAL DATA Ambient tempatemper Temperature Rise IEEE 519 EN 61000-2-2 EN 61000-2-4 IEC/EN 61000-3-2 IEC/EN 61000-3-4 IEC/EN 61000-3-12 注释 / NOTES 典型技术规格 可能因材料和⽣产公差⽽有所不同。 *

 Open the catalog to page 1
sikes harmoic power filter for  90kw ABB  VFD INVERTER  THDI -2

/ Typical performance of the lter at nominal load / Typical performance of the lter over full load range Load = DC-link power of the frequency inverter connected to the lter 负载=连接到滤波器的变频器直流母线功率 Power Factor Power Factor / Dimensions and mounting dimensions

 Open the catalog to page 2
sikes harmoic power filter for  90kw ABB  VFD INVERTER  THDI -3

Electrical Installation Harmonic Filter PHF 005/ PHF 010 contains the following terminals PHF系列 谐波滤波器 PHF 005/PHF 010 含有下列端子 Mains terminals 输⼊端连接到电源 Output terminals to the frequency converter. 输出端连接到变频器 Optional connection terminals for capacitor disconnect. 选配的旁路端⼦⽤于电容中断连接 Temperature switch connected to the frequency converter. Main supply 24V DC 24-240V AC depending on contactor type Frequency converter Capacitor diaconnect (optional)

 Open the catalog to page 3

All Shenzhen Sikes Electric Co., Ltd. catalogs and technical brochures

  1. Transformers

    8  Pages

  2. Chokes

    30  Pages

  3. Resistors

    16  Pages

  4. Load bank

    14  Pages

Archived catalogs

*Prices are pre-tax. They exclude delivery charges and customs duties and do not include additional charges for installation or activation options. Prices are indicative only and may vary by country, with changes to the cost of raw materials and exchange rates.