This document provides a comprehensive guide for selecting dynamic braking units (DBUs) used in regenerative drives. It includes specifications, selection formulas, and product parameters for various braking units and resistors.

1. Specifications and Parameters
The brochure outlines the specifications for dynamic braking units, including safety features, compatibility, and economic benefits. Key safety features include IGBT short circuit protection to prevent fire hazards. The units are designed for compatibility with general resistors and offer adjustable chopper voltage suitable for various inverters.

2. Selection Formula
The selection of braking units is based on formulas that consider the resistance value (R) and power (Pr) of the braking resistor. The formulas incorporate factors such as the voltage value of the inverter's braking circuit, braking torque, and the power of the electric motor.

3. Product Profiles
The DBU's primary function is to convert regenerative energy from motor deceleration into heat, improving braking performance and reducing deceleration time. The document provides detailed profiles for different series of braking units, including their dimensions and power ratings.

4. Selection Procedures
The brochure includes a selection table that guides users in choosing the appropriate braking unit and resistor configuration based on inverter power and application requirements. It categorizes applications by braking activation voltage and usage scenarios, such as elevators and cranes.

5. Product Safety and Installation
Warnings are provided to prevent injury or electric shock during installation. Users are advised to follow manual instructions, disconnect power before opening the unit, and use proper grounding techniques.

6. Selection Tables
The document contains detailed tables listing various braking unit models, their power ratings, chopper voltages, and dimensions. It also provides guidance on the number of units and resistors required for different power levels and applications.

Conclusion
This brochure serves as a technical guide for selecting and configuring dynamic braking units in various industrial applications, ensuring optimal performance and safety.
See more

Catalog excerpts

Dynamic Braking Units-1

www.sikes-elec.com www.sikes-elec.cn 西凯士·制动单元选型手册 Dynamic Braking Unit Selection Brochure Dynamic Braking Unit 制动单元 Filter 滤波器 Regenerative drive 回馈装置

 Open the catalog to page 1
Dynamic Braking Units-2

Dynamic Braking Unit 制动单元 03 Selection Formula 选型公式 04 Braking Unit 制动单元(LN) SIKES ELECTRIC(HK) CO., LTD. 西凱士 電氣(香港)有限公司 SHENZHEN SIKES ELECTRIC CO., LTD. 深圳市西凯士电气有限公司 Add.:Bldg. B,Huayuan industrial park ,Phoenix, Fuyong ST 518103, Baoan district, Shenzhen, Guangdong, China 地址:中国·广东深圳市宝安区福永街道凤凰华源工业区B栋 Tel: 0086-755-33859592/33859590 Fax: 0086-755-33859590-810 Email: [email protected] www.sikes-elec.com www.sikes-elec.cn E-commerce Platform: http://sikes.en.alibaba.com Products listed in the catalogue are our standard products,the parameters are for reference only.Please contact our sales...

 Open the catalog to page 2
Dynamic Braking Units-3

Dynamic Braking Resistor Calculation 选型公式 Braking Resistor's Resistance Value:R Braking Resistor's Resistance Value: R= U dc2 Voltage value of chopper wave of inverter's braking circuit K:Folds of braking torque 1.2-2.0 P:Frequency of the selected converter Braking Resistor's power:Pr Braking Resistor's power:Pr= U dc 2所选变频器制动回路的斩波电压值 K所需的制动转矩倍数1.2-2.0 P所选变频器的功率 制动电阻器的功率Pr 制动电阻器的功率Pr= Po:the power of electric motor ΔK:folds of allowable transient operating overload. The exactvalue shall be determined by referring to the chart according to operating conditions. P1 :the average braking power that...

 Open the catalog to page 3
Dynamic Braking Units-4

Dynamic Braking Unit 制动单元 Product Profile 产品简述 The function of the DBU braking unit is to divert in to a braking resistor,the regenerative energy produced in the process of decelerating the motor, converting that energy into heat.Regenerative energy flows from the motor into the inverter DC Bus ,manifested as increased bus voltage .The advantage gained using the DBU is improved braking performance and shorter deceleration time of the load. Ln系列制动单元的作用是将马达在减速的过程中间生的再生能量,以热能的形式消耗在制动电阻上,从 而改善变频器的制动性能及缩短变频器的制动时间。 Product Parameters ■ SAFETY:The tripping function against IGBT short circuit breakdown...

 Open the catalog to page 4
Dynamic Braking Units-5

Dynamic Braking Unit 制动单元 D D1 BRAKING UNIT BRAKING UNIT Selection Table 选型表 Picture NO. 图号 Chopper Voltage 斩波电压

 Open the catalog to page 5
Dynamic Braking Units-6

ED=20%,braking activation voltage=670VDC,Apply to common machine and the elevator (less than 10 layers,),crane trolley. ED=20%,起始斩波电压VDC=670V,适用普通机械、10层以下电梯,起重机大小车选用。 Inverter Power 变频器功率 (KW) Type 制动单元型号 Quanity of Braking Unit 制动单元数量 Resistor 电阻配置 Quantity of Resistor 电阻数量 Braking torque 制动力矩 Resistance form 电阻形式 Single resistor 单支电阻 Single resistor 单支电阻 Single resistor 单支电阻 Single resistor 单支电阻 Built-in braking unit 内置制动单元 Single resistor 单支电阻 Single resistor 单支电阻 Single resistor 单支电阻 Single resistor 单支电阻 Single resistor 单支电阻 Single resistor 单支电阻 Single resistor 单支电阻 Braking resistor box电阻箱...

 Open the catalog to page 6
Dynamic Braking Units-7

Dynamic Braking Unit 制动单元 ED=30%,braking activation voltage=670VDC,Apply to medium mechanical equipment and elevator(less than 20 layers) ED=30%,起始斩波电压VDC=670V,适用中等机械设备、20层以下电梯选用。 Quanity of Braking Unit 制动单元数量 Resistor 电阻配置 Quantity of Resistor 电阻数量 Braking torque 制动力矩 Resistance form 电阻形式 Single resistor 单支电阻 Single resistor 单支电阻 Single resistor 单支电阻 Single resistor 单支电阻 Single resistor 单支电阻 Single resistor 单支电阻 Inverter Power 变频器功率 (KW) Braking Unit Type 制动单元型号 Built-in braking unit 内置制动单元 Single resistor 单支电阻 Single resistor 单支电阻 Single resistor 单支电阻 Single resistor 单支电阻 Braking resistor...

 Open the catalog to page 7
Dynamic Braking Units-8

ED=40%,braking activation voltage=670VDC,Apply to to more than 30 layers elevators,main hook choice of the light crane. ED=40%,起始斩波电压VDC=670V,适用30以上电梯,轻型起重机主构选用。 Inverter Power 变频器功率 (KW) Braking Unit Type 制动单元型号 Quanity of Braking Unit 制动单元数量 Resistor 电阻配置 Quantity of Resistor 电阻数量 Braking torque 制动力矩 Resistance form 电阻形式 Single resistor 单支电阻 Single resistor 单支电阻 Single resistor 单支电阻 Single resistor 单支电阻 Single resistor 单支电阻 Built-in braking unit 内置制动单元 Single resistor 单支电阻 Single resistor 单支电阻 Single resistor 单支电阻 Braking resistor box电阻箱 Braking resistor box电阻箱 Braking resistor box电阻箱 Braking...

 Open the catalog to page 8

All Shenzhen Sikes Electric Co., Ltd. catalogs and technical brochures

  1. Transformers

    8  Pages

  2. Chokes

    30  Pages

  3. Resistors

    16  Pages

  4. Load bank

    14  Pages

Archived catalogs

*Prices are pre-tax. They exclude delivery charges and customs duties and do not include additional charges for installation or activation options. Prices are indicative only and may vary by country, with changes to the cost of raw materials and exchange rates.