Chokes

Chokes
1 / 30 PagesView full catalog

Chokes

Product catalog summary
Overview: This document is a selection brochure for SIKES Electric's line reactors, also known as chokes. It provides detailed specifications, features, and selection tables for various types of reactors used in electrical systems to improve performance and protect equipment.
Main Sections:
  • DC Reactor (Choke): Designed to reduce current ripple in DC circuits, ensuring continuous current flow and protecting components from pulse current damage. Key specifications include a voltage range of DC 500V-1000V, dielectric strength of AC 3000V/50Hz/5mA, and insulation resistance greater than 100M ohms.
  • AC Input Reactor (Choke): Used on the input side of AC drives to suppress inrush voltage, reduce peak current, and improve power factor. Features include foil winding structure for low resistance and high overload capacity, with insulation class F/H.
  • AC Output Reactor: Details not provided in the excerpt, but typically used to smooth output current and reduce harmonics.
  • Explosion-Proof Reactor: Designed for use in hazardous environments, ensuring safety and reliability.
  • Detuned Reactor: Used to prevent resonance in power systems, improving stability and performance.
  • Load Reactor for Inverter Testing: Specialized reactors for testing inverters, ensuring accurate performance assessments.
  • APF Filter Reactor: Used in active power filter systems to reduce harmonics and improve power quality.
Product Features: The reactors are constructed with high-performance insulation materials and frameless processes for high heat resistance. They use argon arc welding for low noise and stable inductance, and are coiled with foil winding for strong electromagnetic force resistance. The core is made from grain-oriented cold-rolled silicon steel for high reliability and low cost.
Selection Tables: The document includes detailed selection tables for DC and AC reactors, specifying power, rated current, inductance value, weight, and dimensions for various models. These tables assist in choosing the appropriate reactor based on specific application requirements.
Standards and Compliance: Products comply with standards GB19212.1-2008 and GB/T1094.6-2011, ensuring quality and safety in electrical applications.
Contact Information: For further inquiries or custom product requests, contact details for SIKES Electric are provided, including phone numbers, email, and website.
Product Overview: This document provides detailed specifications and features of various types of reactors (chokes) used in electrical systems, particularly focusing on explosion-proof reactors suitable for mining environments and detuned reactors for harmonic suppression.
Specifications: The document lists multiple reactor models with specifications such as power rating, rated current, inductance, insulation class, weight, and dimensions. These reactors are designed for different applications, including AC output, energy feedback, and load testing.
Product Features:
  • Explosion-Proof Reactors: Designed for harsh mining environments, these reactors feature high structural strength, excellent insulation, low temperature rise, and minimal leakage current. They improve input current waveform, balance degree, and system power factor while restraining high harmonics.
  • Detuned Reactors: Used in reactive power compensation to prevent resonance and harmonic amplification. They feature high heat resistance, low loss, and good high-frequency performance.
Design and Standards: The reactors are designed with high linearity and overload capacity, using vacuum pressure impregnation (VPI) for better oil immersion and corrosion resistance. They comply with standards such as IEC289:1987 and GB10229-88.
Environmental and Operational Requirements: Reactors are designed to operate at altitudes up to 1000m, with temperature ranges from -25°C to 45°C, and storage temperatures from -40°C to 70°C. They are suitable for environments with relative humidity between 10% and 90% and have anti-pollution and anti-salt-mist features.
Tables and Diagrams: The document includes selection tables for different reactor types, detailing their specifications and dimensions. It also provides diagrams illustrating the physical layout and terminal configurations of the reactors.
Customization Options: Reactors can be customized according to client requirements, including insulation class and terminal materials.
Overview: The document provides detailed specifications and technical requirements for various types of reactors, including Load Reactors, Drossel and Filtering Reactors, and CKSC Epoxy-resin Filled Dry-type Iron Core Series Reactors. It includes product profiles, features, technical requirements, and selection tables.
Load Reactor Specifications: Designed for inverter testing, these reactors have specific dimensions and are capable of long-term and short-term work. The maximum size is specified as 1000.
Drossel and Filtering Reactor Specifications: These reactors are made with enamel insulated aluminum wire and have a rated voltage of 400V±3%. They feature low noise and high insulation resistance. The insulation grade is H, and they are designed to prevent arcing breakage.
CKSC Epoxy-resin Filled Dry-type Iron Core Series Reactor: These reactors use epoxy resin for solid insulation and are suitable for power systems with AC 50HZ and rated operating voltage up to 6-35kv. They help in restraining high harmonic closing surge and improving power supply quality.
Technical Requirements for APF Filter Reactor: The system voltage is 0.4±10% kv, with rated current and inductance values specified. The reactors have a high capability to handle harmonic currents and are designed to withstand instantaneous voltages up to 1110V. They feature a noise level of less than 60dB at 1M distance.
Standards: The reactors comply with standards such as GB/T 16935.1 for equipment insulation coordination in low-voltage systems and GB/T 1094.6 for reactors.
See more

Catalog excerpts

Chokes-1

www.sikes-elec.com www.sikes-elec.cn 西凯士·电抗器选型手册 Choke(Line Reactor)Selection Brochure Regenerative drive 回馈装置 Dynamic Braking Unit 制动单元

 Open the catalog to page 1
Chokes-2

Line Reactor (Choke)电抗器 06 AC Input Reactor 输入交流电抗器(ACL) 11 AC Output Reactor 输出交流电抗器(OCL) 16 Explosion-Proof Reactor 防爆电抗器 20 Detuned Reactor 解谐电抗器 22 Load Reactor Dedicated For Inverter Testing 变频器测试专用负载电抗器 24 Drossel And Filtering Reactor 高频单相电抗器和滤波电抗器 26 CKSC Epoxy-resin Filled Dry-type Iron Core Series Reactor CKSC环氧浇注干式铁芯串联电抗器 28 APF Filter Reactor APF滤波电抗器 SIKES ELECTRIC(HK) CO., LTD. 西凱士 電氣(香港)有限公司 SHENZHEN SIKES ELECTRIC CO., LTD. 深圳市西凯士电气有限公司 Add.:Bldg. B,Huayuan industrial park ,Phoenix, Fuyong ST 518103, Baoan district, Shenzhen, Guangdong, China 地址:中国·广东深圳市宝安区福永街道凤凰华源工业区B栋 Tel: 0086-755-33859592/33859590...

 Open the catalog to page 2
Chokes-3

DC Reactor( Choke ) 直流电抗器 Product Profile 产品简述 Reduce the current in DC circuit. Ensuring continous current when inductance value reach to a certain degree.Reduce and prevent the rectifier bridge from damaging and capacitance overheating caused by pulse current. Improve power factor, reduce the AC pulse to the DC busbar,limit grid voltage transient. 直流电路中能减少电流脉动,当电感量达到一定量时能保证电流连续不断流。改善电容滤波造成的输入电流波形畸变,减少和防止因冲 击电流造成整流桥损坏和电容过热。提高功率因素,降低直流母线交流脉冲,限制电网电压的瞬变。 Product Features 产品特点 The inside insulation material is of high performance & high temperature resistant,combined with frameless process , the...

 Open the catalog to page 3
Chokes-4

Product Size 产品尺寸图 DC Choke Selection Table for 400V Inverter 400V级变频器直流电抗器选型表 Type 电抗器型号 Rated Current 额定电流 (A)

 Open the catalog to page 4
Chokes-5

DC Reactor( Choke ) 直流电抗器 DC Reactor Selection Table for 690V Inverter 690V级变频器直流电抗器选型表 Reactor Type 电抗器型号 Rated Current 额定电流 (A)

 Open the catalog to page 5
Chokes-6

AC Input Reactor (Choke) 输入交流电抗器 Product Profile 产品简述 In application at AC drive input side to suppress inrush voltage.Reduce inrush & peak current ; Improve the real power factor , restrain the grid harmonics and Improve the input current waveform. 输入电抗器是限流设备,用于驱动器的输入侧,保护交流驱动器不受瞬态 超压的影响。降低浪涌和峰值电流,提高真实功率因数,抑制电网谐波, 改善输入电流波形。 Product Features 产品特点 Excellent property due to foil winding structure,small DC resistance.the rdsistance to electromagnetic force ability is strong,good overload ability in short time;F class insulation materals,so that products can maintain reliable performance capacity.Moreover,combined...

 Open the catalog to page 6
Chokes-7

AC Input Reactor (Choke) 输入交流电抗器 Harmonic solution for the input side of frequency inverter 变频输入端解决方案 Low cost,Simple Installation, Filtering Effect is Limited 成本低,安装易,滤波效果有限 Low cost,Simple Installation, Filtering Effect is Limited 成本低,安装易,滤波效果有限 Low cost,Simple Structure, Limited Effect Moderate Cost,Simple Structure, Better Effect 成本适中,结构简单,效果较好 Moderate Cost,Limited Effect, No Voltage Drop 成本适中,效果有限,不产生压降 Moderate Cost,Limited Effect, No Voltage Drop 成本适中,效果有限,不产生压降 Moderate Cost,Better Effect, Larger Voltage Drop High Cost,Better Effect, Larger Size

 Open the catalog to page 7
Chokes-8

380V AC input reactor (2% reacfance rate)selection table 380V输入交流电抗器(2%电抗率)选型表 Reactor Type 电抗器型号 Rated Inductance Reacf Current Value -ance 额定电流 电感量 rate (A) (mH) 电抗率 (%) Insulation Class 绝缘等级

 Open the catalog to page 8
Chokes-9

Picture A Picture B Picture C D2 D2 Picture D■ 690V AC input reactor (2% reacfance rate)selection table 690V^A^/^^Jn^ ( 2%^Jn$ ) Reactor Type Note/#;£: (1) Detailed information please consult factory. ( 2 ) The leading-out terminals of this product are Copper clad aluminum terminals or Aluminum terminals. it^^^ll^fi^S^llpfi^lpfiE,, ( 3 ) Can be customized.

 Open the catalog to page 9
Chokes-10

690V AC input reactor (3% reacfance rate)selection table reference:! 140V AC input reactor(2% reacfance rate)selection table 690V«tA£jft*in^ (3%B$) «## : 1140V$iA£;ft«n^ (2%®$) Product Size ^SR^S D2 D2 Picture A Picture B Picture C D2 Picture E■ 1140V AC input reactor (2% reacfance rate)selection table 1140V$^A^;^^Jn^ ( 2%^fn$ ) Reactor Type Note/#;£ : (1) Picture C^-^(Tolerance)D:max D1:±1 D2±2 W:max W1:±2 W2:±2 H:max S^^/i^-^(others)±0.5mm ; Picture D^-^(Tolerance)D:max D1:±1 D2±2 W:max W1:±2 W2:±2 H:max S^^^^^(others)±0.5mmo ( 2 ) Can be customized. (3)Class H can be customized. ( 4) The...

 Open the catalog to page 10
Chokes-11

AC Output Reactor(Choke) 输出交流电抗器 Product Profile 产品简述 Smoothing circuit,efficient from IGBT motor drives,so as to extending service life of electric motors.Reduce motor noise and eddy loss.Reduce the leakage current resulted from the output of high harmonic.Protect the electronic power switch within the inverters. 用于平滑滤波,降低瞬变电压dv/dt,延长电机寿命。可以降低电机噪音,减低涡流损耗。降低输出高次 谐波造成的漏电流,保护变频器内部的功率开关器件。 Product Features 产品特点 Selection of silicon steel,ferrite magnetic material of amorphous core according to the frequency of application ;Excellent property due to foll winding structure,small DC resistance ,strong...

 Open the catalog to page 11
Chokes-12

Harmonic solution for the output side of frequency inverter 变频输出端解决方案 Sine wave Filter ① The Length of motor Cable 马达线缆长度 ② Effectively Restrain the Curent of the Moto Shaft 有效的抑制电机轴电流 ③ Effectively Restrain the Common-mode Voltage 有效抑制共模电压 ④ Over voltage of the Motor 马达过电压 ⑤ Solution for Over voltage of Long-term Transmission 长线传输过电压

 Open the catalog to page 12
Chokes-13

AC Output Reactor(Choke) 输出交流电抗器 380V AC output reactor (1% reacfance rate)selection table 380V输出交流电抗器(1%电抗率)选型表 Reactor Type 电抗器型号 Rated Inductance Reacfance Insulation Rate Current Value Class 电抗率 额定电流 电感量 绝缘等级 (%) (A) (mH) Note/备注: (1) Picture C公差(Tolerance) D:max D1:±1 D2±2 W:max W1:±2 W2:±2 H:max H1:±5 H2:±5 E±10,其余未注公差(others)±0.5mm; Picture D公差(Tolerance) D:max D1:±1 D2±2 W:max W1:±2 W2:±2 H:max H1:±5 H2:±5 E±10,其余未注公差(others)±0.5mm。 (2) Can be customized. 以上型号为我司标准品,其它规格可以根据客户要求定制。 (3) Class H can be customized. H级产品可以根据客户要求定制。 380V AC output reactor (2% reacfance rate)selection table...

 Open the catalog to page 13
Chokes-14

■ Product Size ^SR^S 4-A" Picture A Picture B Picture C b"i ! ! Picture E ■ 690V AC output reactor (1% reacfance rate)selection table 690V^ft^^^^^(1%^^$)^M^ Reactor Type Note/#;£ : (1) Picture C^^(Tolerance) D:max D1:±1 D2±2 W:max W1:±2 W2:±2 H:max H1:±5 H2:±5 E±10,S^^;£^-^(others)±0.5mm ; Picture D-^-^(Tolerance) D:max D1:±1 D2±2 W:max W1:±2 W2:±2 H:max H1:±5 H2:±5 E±10,S^^;£^-^(others)±0.5mm0 (2) Can be customized. (3) Class H can be customized. ( 4) The leading-out terminals of this product are Copper clad aluminum terminals or Aluminum terminals. it^^^ll^fi^S^llpfi^lpfiE,,

 Open the catalog to page 14

All Shenzhen Sikes Electric Co., Ltd. catalogs and technical brochures

  1. Transformers

    8  Pages

  2. Resistors

    16  Pages

  3. Load bank

    14  Pages

Archived catalogs

*Prices are pre-tax. They exclude delivery charges and customs duties and do not include additional charges for installation or activation options. Prices are indicative only and may vary by country, with changes to the cost of raw materials and exchange rates.