Standard Signal Isolator www.ce-transducer.com Specifications: Part Number CE-IZ07-34 CE-IZ07-54 CE-IZ07-64 CE-IZ27-34 CE-IZ27-54 CE-IZ27-64 CE-IZ27-T4 Response Overload Time Capacity Voltage output: ≤3mA ≤150mS Current output: ≤300Ω 2 times of rate Din input, rail/ 10times Screw /sec Part Numbers: Series Power Supply Case Style Rated Input Example: CE-IZ07-54MS3-0.5/4-20mA Description: 1-element standard signal isolator, Output: 4-20mA, Power Supply: +24V, No aperture, Case Style: S3, Accuracy: 0.5, Input current: 4-20mA Connections Diagram (see page for mounting dimensions)
Open the catalog to page 1Application It can be used in the monitor system of oil, chemistry or energy distribution industry. And it will consummate the I/O function of the system. Case Style
Open the catalog to page 2Center of the sliding track Please make sure to connect input, output and power supply correctly in accordance with the connection diagram of your part number before power on. The standard signal isolators should be used only in environments without conductive dust, corrosive or explosive gases. Please take additional and reasonable means for lightning protection, especially when the input and output wires of the standard signal isolator are exposed outdoor. East Block,9/F,Building No. 2,SEG Science&Technology Park,Shenzhen ,P.R.China TEL:+86-755 83766915