Self-powered Transducer
1 /6Pages

Self-powered Transducer

Self-powered Transducer
1 /6Pages

Catalog excerpts

Self-powered Transducer-1

Self Power Transducer www.ce-transducer.com 1.1 self power 1-element current transducer Specifications: Isolator Linearity Phase Voltage Error Deflection Rated Output Part Number Output Response Overload Time Capacity 2.5mA ≤1.5V (input 5A) 35′ ≤0.2% ≤15uS 20 times CE-IJ03-20 Ig 37.5mA Screw/ 2500 or (input300A ≤3.5V Din rail VDC <5/sec at ) /PCB 500A CE-IJ03-30 Vz* 05V >1MΩ CE-IJ03-80 Vd** 010V none ≤1% ≤1S 400/5A CE-IJ03-J0 J*** On-off DC * There are three input group can be chosen 2A/5A/10A, 20A/50A/75A and 100A/150A/200A. And in each group, the jumper can fix the input range of the three. ** There are two input group can be chosen 20A/50A/75A and 100A/150A/200. And the And in each group, the jumper can fix the input range of the three. *** It can connect with AC/DC current/voltage load directly. Part Numbers: Series Power Supply 1: tracking voltage(Vg) 2: tracking current(Ig) CE-IJ03 Case Style Part Number Example: CE-IJ03-10BS2-1.0/0-10A Description: 1-element AC current transducer, Output: tracking voltage0-1V, No power supply, Window: Ф6.5mm, Case style: S2, Accuracy: 1.0, Input current: 0-10A

 Open the catalog to page 1
Self-powered Transducer-2

Connections Diagram (see page 6 for mounting dimensions) + Relay output Fig. 1.2 CE-IJ03 with relay output Fig.1.1 CE-IJ03 with terminal input Voltage output Fig. 1.3 CE-IJ03-x0 with voltage output Monitor the AC current of the motor. Measure/monitor the second side of the CT. “+” which signed in the picture means the same polarity. The size of window must be fit for the conducting wire to pass through. And the terminal input also could be chosen while the input current≤5A. If there is a meter is used to test the output of the transducer, please make sure the accuracy of the meter is higher than...

 Open the catalog to page 2
Self-powered Transducer-3

self power 3-phase current transducer Specifications: Part number Output CE-IJ31-10 Isolation Phase Voltage Linearity Error Deflection 2500VD ≤0.2% C Response Overload Mounting Time Capacity 20 times or Din rail/ <5/sec at Screw 500A Part Numbers: Series Power Supply 1:tracking voltage (Vg) 0: none 2:tracking current (Ig) Case Style Part Number Example: CE-IJ31-10BS3-1.0/0-5A Description: 3-elements AC current transducer, Output: tracking voltage 0-1.2V, No power supply, Aperture: Ф6.5mm, Case style: S3, Accuracy: 1.0, Input current: 0-5A Connections Diagram (see page 6 for mounting dimensions)...

 Open the catalog to page 3
Self-powered Transducer-4

1.2 self power voltage transducer 1.2.1 self power 1-phase voltage transducer Specifications: Part Number Output CE-VJ03-10 CE-VJ03-20 Isolation Linearity Phase Rated Voltage Error Deflection Output Response Overload Mounting Time Capacity Part Numbers: Series Power Supply Case Style Rated Input Part Number Example: CE-VJ03-20MS2-1.0/0-400V Description: 1-phase AC voltage transducer, Output: tracking current 0-1mA, No power supply, No aperture, Case style: S2, Accuracy: 1.0, Input current:0- 400V. Connections Diagram (see page 6 for mounting dimensions) Monitor the voltage of the motors Monitor...

 Open the catalog to page 4
Self-powered Transducer-5

self power 3-phase voltage transducer Specifications: Part number Linearity Phase Rated Isolator Error Deflection Output Voltage Response Overload Mounting Time Capacity 2 times Din rail <5/sec /Screw Part Numbers: Power Supply Case Style Rated Input Part Number Example: CE-VJ41-10MS3-0.5/0-380V Description: 3-phase 4-wire AC voltage transducer, Output: tracking voltage 0-1.2V, No power supply, No aperture, Case style: S3, Accuracy: 0.5, Input current: 0-380V. Connections Diagram (see page 6 for mounting dimensions) Monitor the voltage of the motors Monitor the secondary side of the VT “+” which...

 Open the catalog to page 5
Self-powered Transducer-6

Case Style Mounting Dimensions Termi nnaIs East Block,9/F,Building No. 2,SEG Science&Technology Park,Shenzhen ,P.R.China

 Open the catalog to page 6

Archived catalogs

*Prices are pre-tax. They exclude delivery charges and customs duties and do not include additional charges for installation or activation options. Prices are indicative only and may vary by country, with changes to the cost of raw materials and exchange rates.