Overview: The Series CE-A digital electrical parameter transducer is designed for measuring AC/DC parameters, supporting single or multi-parameter measurements. It measures true RMS voltage and current, frequency, power, power factor, and total energy. Communication interfaces include RS-485 or RS-232C with ASCII or MODBUS protocols, featuring enhanced safety through double or treble isolation.
Part Numbers: Part numbers adhere to the national standard GB7666-87, indicating measuring range, isolation type, output interface, and case style. Examples include CE-AJ11 for single element AC multi-parameter transducers and CE-AJ42 for 3-phase 4-wire systems.
Specifications: The transducers offer high accuracy (0.2% or 0.5%), support various baud rates, and can communicate over distances up to 1200 meters. They are designed to withstand high isolation voltages and have a mean time between failures (MTBF) of over 30,000 hours.
Product Tree: Various models are detailed, including single element and multi-phase transducers, each with specific features and connection diagrams. For example, the CE-AJ11 model is a single element transducer with double isolation.
Communication Protocols: Supports ASCII and MODBUS protocols with detailed command sets for data reading and configuration. Features include energy data protection during power failures.
System Connecting and Programming: Instructions are provided for connecting and programming transducers, including power supply options and case styles.
Ordering Instructions: Guidelines include specifying measuring range and desired features, with warranty and user notices included.
Electrical Multi-parameter Digital Transducer Connections: Connection details for a 3-phase 3-wire transducer with treble isolation in an S5 case style are provided.
3-phase 4-wire Electrical Multi-parameter Digital Transducer: Models like CE-AJ41 and CE-AJ42 offer high accuracy and true RMS data output for multiple parameters. Input range includes AC 45-65Hz, voltage up to 500V, and current up to 100A.
AC Current Single Parameter Digital Transducer: Models like CE-AI12 offer 0.2% accuracy and true RMS current data output, with an input range up to 100A.
AC Voltage Single Parameter Digital Transducer: Models like CE-AV12 offer 0.2% accuracy and true RMS voltage data output, with input ranges up to 500V.
DC Current/Voltage Single Parameter Digital Transducer: Models like CE-AZ11 offer 0.2% accuracy, outputting data as a percentage of the maximum measurable range.
Switch Values Data Logger: Models like CE-AK10 provide RS-485 output with MODBUS protocol, operating with passive contacts.
Ethernet Converter: Models like CE-485B convert RS-485 and RS-232 to TCP/IP, supporting various protocols and baud rates.
ASCII Format Communication Protocol: Command sets for communication using ASCII format are outlined, including reading and configuring transducer data.
Specifications and Measurements: Instructions on calculating real current values using percentage ratios are provided, along with command responses for voltage, current, and power calculations.
MODBUS Protocol: Details on MODBUS protocol compatibility, message formats, and examples for reading and writing register data are included.
Data Formats and Calculations: Data formats for current, voltage, and power are explained, with calculations for various electrical parameters.
System Connection and Programming: Instructions for connecting transducers in a measuring and controlling system using RS-485 connections are provided.
System Connectivity and Configuration: The CE-A transducer is designed for high reliability, capable of connecting to industrial digital control systems using RS-485 bus communication technology.
Measuring Range Selection: CE-A products offer a measuring range for voltage (0~500V) and current (1~25A), with protection against damage from excessive inputs.
Configuration Process: Each transducer must be configured before network connection, requiring an RS-485/RS-232C converter and application software.
Data Acquisition: Once connected, the transducer responds to read data commands, with data refreshed every 100ms.
Power Supply and Case Style: Models like CE-WYS-1 offer specific input and output parameters, with case styles including S3 and N.
Ordering Instructions: Orders must include complete product descriptions, part numbers, and specifications, with confirmation required via fax or email.
Usage Notices: Users must verify product part numbers and ensure correct connections before powering on, avoiding environmental conditions like conductive dust.
Warranty and Support: The company offers a warranty against defects and provides technical support via fax or email.
See more

Catalog excerpts

DIGITAL TRANSDUCER Series CE?A-1

ELECTRICAL PARAMETER DIGITAL TRANSDUCER “Green is the symbol of life, CE is pledge of reliability” Shenzhen Sensor Electronic Technology Co., Ltd. East Block, 9/F., Building No. 2, SEG Science & Technology Park, Shenzhen, P.R. China http://www.ce-transducer.com http://www.sset-transducer.com E-mail: [email protected]

 Open the catalog to page 1
DIGITAL TRANSDUCER Series CE?A-2

Shenzhen Sensor Electronic Technology Co., Ltd. List of main functional part numbers and specifications…………………4 List of main functional part numbers………………………………………………4 General specifications…………………………………………………………5 Product tree………………………………………………………………6 1 element AC Electrical Multi-parameter Digital Transducer CE-AJ11, CEAJ12……………6 3-phase 3-wireElectrical Multi-parameter Digital Transducer CE-AJ31, CE-AJ32……………7 3-phase 4-wire Electrical Multi-parameter Digital Transducer CE-AJ41, CE-AJ42…………9 AC Current Single Parameter Digital Transducer CE-AI12, CE-AI22, CE-AI32……………11 AC Voltage Single Parameter...

 Open the catalog to page 2
DIGITAL TRANSDUCER Series CE?A-3

Shenzhen Sensor Electronic Technology Co., Ltd. 7.2 Ordering Instructions and Notice to User………………………………31 8.1 Ordering Instructions……………………………………………………… 31 8.2 Notice to User………………………………………………………………31 8.3 Warranty Service……………………………………………………………31

 Open the catalog to page 3
DIGITAL TRANSDUCER Series CE?A-4

Shenzhen Sensor Electronic Technology Co., Ltd. Overview Series CE-A digital electrical parameter Transducer is intelligent AC/DC parameters measuring device. There are many single or multi-parameter part numbers. For DC part numbers, they can measure voltage and current. For AC part numbers, they can be used in 3-phase 3-wire or 3-phase 4-wire systems to measure up to 15 parameters simultaneously including true RMS of voltage Ua, Ub and Uc, true RMS of current Ia, Ib and Ic, frequency F, active power P, reactive power Q, power factor Cosφ, total active energy Kwh, total reactive energy Kvarh...

 Open the catalog to page 4
DIGITAL TRANSDUCER Series CE?A-5

Shenzhen Sensor Electronic Technology Co., Ltd. Part Numbers The rule for Part Number of CE-A transducer is in conformity with national standard GB7666-87 of the People’s Republic of China. Main Code Input characteristics J: AC multi-parameter; I: AC Current; V: AC Voltage; D: DC Current and Voltage; Z: DC Current; U: DC Voltage Function codes The first digit: 1: 1 element; 2: 2 elements 3: 3-phase 3-wire or 3 elements; 4: 3-phase 4-wire. The second digit: 1: Double-isolation; 2: Treble-isolation. For New Function A: (reserved); B: with energy data power failure protection function Output Interface...

 Open the catalog to page 5
DIGITAL TRANSDUCER Series CE?A-6

Shenzhen Sensor Electronic Technology Co., Ltd. S3; accuracy: 0.5%; measuring range: voltage: 0110V, current: 05A. Typical Example 2: CE-AJ42-34MN-0.5/380V*5A: 3-phase 4-wire AC multi-parameter digital electrical transducer; treble isolation; output: MODBUS protocol, RS-485 interface; power source: +24V; no aperture (input connection through terminals); Case style: N; accuracy: 0.5%; measuring range: voltage: AC 0380V, current: AC 05A.

 Open the catalog to page 6
DIGITAL TRANSDUCER Series CE?A-7

Shenzhen Sensor Electronic Technology Co., Ltd. List of main functional part numbers and specifications 2.1 List of main functional part numbers No. Functions Part Number Page Double ASCII format RS485 CE-AJ11-1XBS3-0.5/XXXV*XXA S3 case isolation MODBUS RS485 CE-AJ11-3XBS3-0.5/XXXV*XXA style Treble ASCII format RS485 CE-AJ12-1XBS3-0.5/XXXV*XXA Single 6 isolation MODBUS RS485 CE-AJ12-3XBS3-0.5/XXXV*XXA phase N case Treble ASCII format RS485 CE-AJ12-1XMN-0.5/XXXV*XXA style isolation MODBUS RS485 CE-AJ12-3XMN-0.5/XXXV*XXA Double ASCII format RS485 CE-AJ31-1XBS3-0.5/XXXV*XXA isolation MODBUS RS485...

 Open the catalog to page 7
DIGITAL TRANSDUCER Series CE?A-8

Shenzhen Sensor Electronic Technology Co., Ltd. 2.2 General specifications Communication Communication distance Max. number of nodes RS-485 twisted pair line A/D speed Working temperature Remarks 0.2% for voltage & current measuring half duplex operation Repeater can be used to extend communication distance node ESD protection and thermosnap mS -10℃ − +55℃ 2500V DC for 1 min. between input and output. 2500V DC for 1 min. between input and power supply. 2500V DC for 1 min. between output and power supply. 2 x Voltage span for 1 sec. 10 times with interval of 10 sec. 10 x Current span for 1 sec....

 Open the catalog to page 8
DIGITAL TRANSDUCER Series CE?A-9

Shenzhen Sensor Electronic Technology Co., Ltd. 3. Product tree 3.1 1 element AC Electrical Multi-parameter Digital Transducer 3.1.1 Part numbers CE-AJ11——1 element, double isolation, S3 case style. CE-AJ12——1 element, treble isolation, S3 or N or S5 case style. 3.1.2 Features l Accuracy—— Frequency: 0.05Hz. Voltage, current, power factor, active power, reactive power, active energy, reactive energy: 0.5%. (Accuracy, linearity and quotation error are ignored when the input voltage is below 5% of span.) l Data output——True RMS of voltage Ua, RMS of current Ia, frequency F, active power P (positive...

 Open the catalog to page 9
DIGITAL TRANSDUCER Series CE?A-10

Shenzhen Sensor Electronic Technology Co., Ltd. 3.1.4.3 See Fig. 3.1.4.3 for Connections of 1 element AC Electrical Multi-parameter Digital Transducer, treble isolation, N case style. See Fig. 3.1.4.4 for Connections of 1 element AC Electrical Multi-parameter Digital Transducer, treble isolation, S5 case style. 3.2 3-phase 3-wire (Two-wattmeter method) Electrical Multi-parameter Digital Transducer 3.2.1 Part numbers CE-AJ31——3-phase 3-wire (two-wattmeter method), double isolation, S3 case style. CE-AJ32——3-phase 3-wire (two-wattmeter method), treble isolation, N, S3 and S5 case style. 3.2.2 Features...