1. Catalogs
  2. SHENZHEN SENSOR ELECTRONIC TECHNOLOGY Co., LTD.
  3. CE-T Catalogue for Transducer with Analog Output

CE-T Catalogue for Transducer with Analog Output

CE-T Catalogue for Transducer with Analog Output
1 / 84 PagesView full catalog

CE-T Catalogue for Transducer with Analog Output

Product catalog summary
Introduction
Shenzhen Sensor Electronic Technology Co., Ltd is a company specializing in the research, development, and manufacturing of electrical transducers. The company prioritizes quality, with products certified to ISO 9001:2000 standards and approved by UL, CUL, CMC, CE, and RoHS. The CE Series monitors electrical parameters such as current, voltage, power, and frequency using technologies like electrical induction, Hall Effect, and magnetic modulation.
Product Categories
The CE Series includes:
  • CE-T series: Provides analog output signals (e.g., 0-5 Vdc, 4-20mA).
  • CE-A series: Provides digital output signals (e.g., RS485/232).
  • CE-H series: Hall effect transducers.
Key Features
  • Micro miniaturization with surface mounting technology.
  • Modularization with unique PCB functions.
  • High reliability and precision-grade components.
  • Low power consumption and high efficiency.
  • High dielectric withstand voltage.
  • Single-sided input power requirement for easy installation.
Management and Mission
The company’s management concept emphasizes environmental responsibility and reliability, while its mission focuses on quality, reliability, and customer satisfaction.
Chapter 1: Selection Guide
This section provides instructions for selecting part numbers based on input characteristics, function codes, case styles, accuracy, and power source.
Chapter 2: Product Overview
Output function codes and typical operating specifications are detailed, including accuracy, thermal drift, output ripple, and operating conditions.
Chapter 3: Details of the Electrical Transducer
This chapter covers various transducers, including current, voltage, frequency, and power transducers. Specifications such as power consumption, isolation voltage, response time, and overload capacity are provided.
Chapter 4: Case Style and Mounting Diagram
Details on case styles and mounting dimensions are provided for proper installation.
Chapter 5: Notes for Ordering
Instructions for ordering, installation notes, and warranty service information are included.
Conclusion
Shenzhen Sensor Electronic Technology Co., Ltd offers a comprehensive range of high-quality electrical transducers suitable for various applications, backed by extensive certifications and a commitment to customer satisfaction.
Specifications and Features
1. Motor Efficiency and Power Sensing: The document outlines the importance of motor efficiency and multi-point power sensing for energy management. It highlights the capability of remote power sensing over long distances.
2. Power Transducer: The output signal of a 3-phase power transducer corresponds to the total power of three phases. For currents larger than 25A, an AC current mutual inductor (CT) is recommended.
Notices
1. Input current must pass through the window in the specified direction.
2. Load current should not exceed the maximum value allowed by relay contacts.
3. Power supply should be stabilized within ±5%.
Transducer Specifications
1. AC/DC Offside Alarm Transducer: Features electromagnetic isolation, various input frequencies, and overload capacities. It includes relay contact outputs and is mounted via screw or DIN rail.
2. Standard Signal Isolator: Used in monitoring systems for oil, chemistry, or energy distribution. It provides isolation voltage and linearity error specifications.
3. Self Power Transducers: Includes current and voltage transducers for monitoring AC currents and voltages. They offer tracking voltage and current outputs with specified accuracy and input ranges.
Applications
1. Load monitoring of DC power supply systems.
2. Safety protection for electric control equipment.
3. Monitoring motor faults and heating elements.
4. Industrial instrumentation and process control loops.
Recommendations
1. Ensure correct connection of input, output, and power supply before powering on.
2. Use in environments free from conductive dust, corrosive, or explosive gases.
3. Implement lightning protection for outdoor exposed wires.
Diagrams and Figures
The document includes various connection diagrams and case styles for different transducer models, emphasizing the importance of correct installation and usage.
See more

Catalog excerpts

CE-T Catalogue for Transducer with Analog Output-1

ELECTRICAL TRANSDUCER CE-T Series

 Open the catalog to page 1
CE-T Catalogue for Transducer with Analog Output-2

Introduction Shenzhen Sensor Electronic Technology Co., Ltd specializes in researching, developing and manufacturing of electrical transducers. Our advanced test instrumentation and engineering capabilities provide a most favorable environment for transducer manufacturing. Our quality and inspection departments are among the most advanced in China. The output of our production facility is over one hundred thousand units annually. The most important aspect of our production is “Quality”. Our products are manufactured and certified to the 2000 quality standards of ISO 9001. The transducers have...

 Open the catalog to page 2
CE-T Catalogue for Transducer with Analog Output-3

Chapter 1 Selection Guide 1.1 1.2 Chapter 4 Case style and Mounting Diagram 4.1 4.2 Chapter 5 Notes for Ordering 5.1 5.2 5.3

 Open the catalog to page 3
CE-T Catalogue for Transducer with Analog Output-4

Chapter 1 Part Number Selection Guide 1.1 Part Number Please follow the instruction below to fix the full part number, one square one code, from left to right. Series Input parameter I: current V: voltage F: frequency P: active power Q: inactive power G: current & voltage combination W: location (potentiometer); R: resistance Input characteristics J: AC; Z: DC; H: AC/DC; M: pulsating DC; B: bi-directional DC (Leave blank for power and frequency) Output functions 1: tracking voltage output (Vg); 2: tracking current output(Ig); 3: 0~5V(Vz); 4: 0~20mA(Iz); 5: 4~20mA(Iy); 6: 1~5V(Vy); 7: 4~20mA loop...

 Open the catalog to page 4
CE-T Catalogue for Transducer with Analog Output-5

1.2 Main Series List MAIN SERIES LIST FOR CE-T ANALOG ELECTRICAL PARAMETER TRANSDUCER FUNCTION TYPE 1 element AC 3 elements Current Frequency Split Core Power supply Self Power Current Self Power Voltage

 Open the catalog to page 5
CE-T Catalogue for Transducer with Analog Output-6

Chapter 2 Product Overview 2.1 Output Function Codes Tracking Output Tracking Output 0-5V DC, can be connected direct to A/D converter, digit panel, indicator, PLC 0-20mA DC, suitable for long distance signal transmission, resistance to interference. 4-20mA DC, suitable for long distance signal transmission, resistance to interference. 1-5V DC, can be connected direct to A/D converter, digit panel, indicator, 4-20mA DC, 2-wire, loop powered connection, resistance to interference. 0-10V DC, can be connected direct to digit panel, indicator etc. (auxiliary Power supply ≥15V). Relay contact Apply...

 Open the catalog to page 6
CE-T Catalogue for Transducer with Analog Output-7

2.2 Typical Operating Specifications Data Item Test Condition Accuracy 0.2 Thermal Drift Output Ripple Operating Temperature Isolation With standing Voltage Power ConsumptionmW Output Load Input / Output Graphs. Output Input Uni-direction input vs 0-5V output Bi-direction input vs bi-directional output Output Uni-direction input vs 0-20 mA output Uni-direction input vs 4~20 mA output 4

 Open the catalog to page 7
CE-T Catalogue for Transducer with Analog Output-8

Chapter 3 Details of the Electrical Transducer 3.1 Current Transducer 3.1.1 Specifications: Series Operating Principle Isolation Voltage Response Time Overload Capacity Power ConsumptionmW Vz,Vd,Vg, Iz Output Part Numbers: Power Supply Rated Input Case Style * Output types Vg,Vy,Vd,Id are not available in series CE-IJ03A. ** Loop resistance from 0 to 250Ω. Contact factory for loop resistance above 250 Ω *** Select 24V Power supply for output of 4~20mA Id; Part Number Example: CE-IJ03-54ES3-O.5/0~50A Description: 1-element AC Current Transducer, average RMS, Output: 4~20mA, Power supply: +24V...

 Open the catalog to page 8
CE-T Catalogue for Transducer with Analog Output-9

Signal Signal Voltage Signal Output Current Signal Output Power Supply Power Supply Fig. 3.13 for CE-IJ03, CE-IJ03A Terminal Input, Voltage Output, Case-S Fig. 3.1.4 for CE-IJ03, CE-IJ03A Terminal Input, Current Output, Case-S, Voltage Current Signal Output Signal output Power Supply Power Supply Fig. 3.1.5 for CE-IJ03, CE-IJ03A Window Input, Voltage Output, Case style S Fig. 3.1.7 for CE-IJ03 Power Supply 220V/110V Window Input, Case style S Fig. 3.1.6 for CE-IJ03, CE-IJ03A Window Input, Current Output, Case style S Fig. 3.1.8 for CE-IJ03 Power Supply220V/110V terminal Input, Current Output,...

 Open the catalog to page 9
CE-T Catalogue for Transducer with Analog Output-10

3.1.2 3-elements AC Current Transducer Specifications: Power Consumption Series Response Time Part Numbers: Series Case Style *Tracking output (Vg,Iz,Vd) type not available in series CE-IJ31A ** Loop resistance from 0 to 250Ω. Contact factory for loop resistance above 250 Ω ***When select MSK case style, the input should be ≤5A Part Number Example: CE-IJ31-32BS3-0.5/0~5A Description: 3 elements AC Current Transducer, average RMS, Output: 0-5Vdc, Power supply: +12Vdc, Aperture: Ф6.5mm, Case style: S3, Accuracy: 0.5 %, Input: 0-5A AC. Connections Diagram (See Chapter4 for mounting dimensions) Signal...

 Open the catalog to page 10
CE-T Catalogue for Transducer with Analog Output-11

Signal Output 3 Signal Output 2 Signal Output 1 Phase fired controlled heaters Quickly varying motor loads Chopped wave form drivers Harmonic currents Notice: 1. The output signal and the power supply must be grounded in common at terminal 6. 2. For application above 25 Amp, It is suggested to use an external current transformer. Connect the secondary output of the current transformer to the input of the transducers. 3. There is no polarity requirement for the input signal connection.

 Open the catalog to page 11
CE-T Catalogue for Transducer with Analog Output-12

Specifications: Power Consumption Series Iz Output Photoelectric Isolation/ Treble isolation* Modulation Isolation Hall Effect Isolation Modulation Isolation l Treble Isolation: the input, output and power supply is isolated from each other. Part Numbers: Series Power Supply Rated Input Case Style * Loop resistance from 0 to 250Ω. Contact factory for loop resistance above 250 Ω Part Number Example: CE-IZ01-32MS2-0.2/0-1A Description: 1- Element DC Current Transducer, average RMS, Output: 0~5V DC, Power supply: +12V DC, No window (Terminal input), Accuracy: 0.2%, Case style: S2, Input: 0-1A. Connections...

 Open the catalog to page 12
CE-T Catalogue for Transducer with Analog Output-13

Signal Input Signal Input Current Signal Output Voltage Signal Output Fig. 3.1.14CE-IZ02 Power supply Voltage Output, Case style S Power supply Fig. 3.1.15 CE-IZ02 Current Output, Case style S Voltage Signal Output Frequency Signal Output Power supply Fig 3.1.16 CE-IZ02 Frequency Output, Case style S Power supply Fig. 3.1.17 CE-IZ04, CE-IZ06 Voltage Output, Case style S Vcc Frequency Signal Output Current Signal Power Supply Power Supply Fig. 3.1.18 CE-IZ04, CE-IZ06 Window Input, Current Output, Case style S Fig. 3.1.20 CE-IZ02 Voltage Output, Case style H2 Fig. 3.1.19 CE-IZ04, CE-IZ06 Frequency...

 Open the catalog to page 13

Archived catalogs

*Prices are pre-tax. They exclude delivery charges and customs duties and do not include additional charges for installation or activation options. Prices are indicative only and may vary by country, with changes to the cost of raw materials and exchange rates.