WTS6X Single-Axis Tilt Sensor Product Manual V2.0-2026-9-28
Open the catalog to page 1Dynamic Sensing • Precision Measurement and Control ❖ Input overvoltage and overcurrent protection; ❖ Output surge protection; Product Introduction- The WTS6X single-axis tilt sensor is a cost-effective tilt-measurement solution developed independently by Ruicom Technology. It features a next-generation, interference-resistant hardware platform and an integrated capacitive MEMS sensing unit. The device offers exceptional performance across a wide temperature range, superior vibration resistance, and long-term operational reliability, with a design service life of up to 10 years. Utilizing a non-contact,...
Open the catalog to page 2Dynamic Sensing • Precision Measurement and Control Product Dimensions Enclosure dimensions:L61 xW35xH21 mm Mounting screws: 3 x M4 screws
Open the catalog to page 3Dynamic Sensing • Precision Measurement and Control Thread Color 1. An inclination sensor measures the tilt angle of an object by detecting the Earth's gravitational field. For optimal measurement accuracy, ensure that the sensor's sensing axis is aligned parallel to the tilt axis of the object being measured. The sensor must be mounted securely on a flat, stable surface; an uneven mounting surface may introduce errors in the measured tilt angle. 2. This sensor features an IP67 ingress protection rating, meaning it is resistant to rain and high-pressure water jets. However, do not submerge the...
Open the catalog to page 4Dynamic Sensing • Precision Measurement and Control Data Value Name Data Type Value Range X-axis angle value -high byte X-axis angle value -low byte Set/clear relative zero point Device address Baud rate Measurement Range Measurement Range 5A5AH Use 03H to read registers, 06H to write to registers, and 42H to read the local device address. Register Address High Byte Register Address Low Byte Register Address High Byte Register Address Low Byte Example: Send command: 01 06 00 07 05 05 [CRC Low] [CRC High] Return data: 01 06 00 07 05 05 [CRC Low] [CRC High] This command sets the sensor's address...
Open the catalog to page 5Dynamic Sensing • Precision Measurement and Control Baud rate starting address (high byte) Baud rate starting address (low byte) Baud rate code (high byte) Baud rate code (low byte) Example: Command sent: 01 06 00 08 A0 A0 [CRC Low] [CRC High] Data returned: 01 06 00 08 A0 A0 [CRC Low] [CRC High] This command sets the sensor's baud rate to 4800 bps; the setting takes effect after a restart. Note: a. The baud rate setting becomes effective after a successful acknowledgment and a subsequent restart. b. Supported baud rates: A0-4800, A1 -9600, A2-19200. Set/Cancel Set/Cancel Relative Zero Relative...