Open the catalog to page 1Product Introduction The VTS6D is a high-precision industrial vibration and tilt sensor developed by Ruicom Technology. Each unit undergoes full-temperature-range calibration, compensation, and stability testing before leaving the factory, ensuring reliable measurements even in complex environments. The sensor features an integrated FFT algorithm that accurately captures mechanical vibrations in the 0.5-20 Hz range, calculating both peak vibration velocity and maximum displacement. It supports various communication protocols, including MODBUS, and comes with data analysis software for real-time...
Open the catalog to page 2Measurement range Measurement axis Dual Dual Dual Dual Axis Axis Axis Axis 3 Temperature coefficient of zero Temperature coefficient of sensitivity Power-on startup time Frequency response Output rate Output signal Electromagnetic compatibility (EMC) Insulation resistance Shock resistance Vibration resistance Waterproof rating RS485/RS232/RS422 Optional In accordance with EN 61000 and GB/T 17626 >100 MQ Includes a 2-meter cable as standard / Weight <194g 1) Resolution: Refers to the smallest detectable change in angle within the sensor's effective measurement range; it reflects the sensor's ability...
Open the catalog to page 3Dynamic Sensing ■ Precision Measurement and ControlElectrical Parameters Parameters Example: VTS6D10-232SP-H: ±10° measurement range / RS232 signal output / SP serial communication protocol / horizontal mounting. This device employs an imported core control unit based on the principle of a miniature capacitive pendulum. Utilizing the force of gravity, when the tilt-sensing unit inclines, gravity exerts a component force on the internal pendulum, causing a change in capacitance. By amplifying, filtering, and processing this capacitance signal, the device determines the angle of inclination. The...
Open the catalog to page 4Dynamic Sensing ■ Precision Measurement and Control Working Principle of Vibration- A change in an object's state of motion produces acceleration. Using the spectral transformation method, the acceleration spectrum is first converted into a displacement spectrum. Next, the amplitude, angular frequency, and initial phase angle corresponding to each frequency component in the displacement spectrum are calculated. Finally, these individual displacement components are superimposed to obtain the vibrational displacement. Vibration parameters and indicators- The vibration frequency, velocity, and displacement...
Open the catalog to page 5Dynamic Sensing · Precision Measurement and Control RS422 Pinout and Wire Color Definitions Pin/Wire Color Definition Positive power terminal Negative power terminal Signal Ground Signal ground Product Dimensions Recommended screws: 4×M6 screws
Open the catalog to page 6Dynamic Sensing · Precision Measurement and Control Measurement direction Indicator Light Function Description The red status indicator remains steadily lit when powered on, and flashes during communication. illustration of Vibration Amplitude Measurement
Open the catalog to page 7Dynamic Sensing ■ Precision Measurement and Control & Communication Protocol The product supports both serial communication protocols and the MODBUS RTU protocol. The default configuration parameters for these protocols are as follows:_
Open the catalog to page 8Serial Baud Rate • Serial Communication Protocol 1. Data frame format: Default communication parameters: Address 0, baud rate 9600, 1 start bit, 8 data bits, no parity, 1 stop bit; Valid address range: 0-254; Data length: The length from the "data length" field through the checksum (inclusive); Data field: Content and length vary depending on the command byte; Checksum: The sum of the data length, address code, command byte, and data field, excluding any carry (i.e., Sum & 0xFF). 2. Command Word Parsing__
Open the catalog to page 9Dynamic Sensing · Precision Measurement and Control Setting Relative/Absolute Zero Point: The current angle can be set as zero degrees for relative measurement; alternatively, the factory-default absolute zero DE Checksum—the sum of all data bytes in hexadecimal (excluding the header `0x68`). If the sum exceeds one byte, only the lowest byte is used. Data Field (0 bytes) Command with no data field. Data Field (12 bytes) 10 00 02 60 The four bytes highlighted in red represent the X-axis acceleration, formatted as packed BCD. The high bit 0 of the first byte is the sign bit (0 for positive, 1 for...
Open the catalog to page 10Dynamic Sensing ■ Precision Measurement and Control point can be restored. Example: 68 05 00 05 00 0A 0X85 Sensor response command 0X0B Setting Serial Port Baud Rate 0X8B Sensor response command 0X0C Setting Sensor Output Mode Request-Response Mode:The sensor only provides angle data when a read command is sent from the host computer. Automatic Output Mode:The sensor automatically outputs X and Y-axis angles as well as temperature upon power-up. For high-frequency output, please set the baud rate to 115200. Example:68 05 00 0C00 11 0X8C Sensor response command The default address for the sensor...
Open the catalog to page 11Dynamic Sensing ■ Precision Measurement and Control MODBUS uses the RTU mode, employs big-endian byte order for addresses and data items, utilizes CRC16 for data verification, and supports function codes 0x03 (read holding registers) and 0x06 (write single register). 1. Data Frame Format: Default communication parameters: Address 1, baud rate 9600, 1 start bit, 8 data bits, even parity, 1 stop bit; Valid address range: 1-247; CRC check: Covers all bytes preceding the CRC field; uses a 16-bit CRC.
Open the catalog to page 12Dynamic Sensing ■ Precision Measurement and Control 2. Data Types:
Open the catalog to page 13Dynamic Sensing ■ Precision Measurement and Control
Open the catalog to page 14Dynamic Sensing ■ Precision Measurement and Control 4. Reading angle data: Modbus Function Code 03H - Application Example 1 for Data Read Command:
Open the catalog to page 15Dynamic Sensing ■ Precision Measurement and Control Access Register Starting Address Commands must be sent twice in succession to take effect.
Open the catalog to page 16Commands must be sent twice in succession to take effect. The example above configures the byte format as follows: 1 start bit, 8 data bits, no parity, and 1 stop bit. This setting takes effect after the device is powered on again. The factory default configuration is: 1 start bit, 8 data bits, even parity, and 1 stop bit. Note: 0009 is the register address; this register controls the parity bit for the sensor's serial communication. 0000H: 1 start bit, 8 data bits, even parity, 1 stop bit 0001H: 1 start bit, 8 data bits, no parity, 1 stop bit 0002H: 1 start bit, 8 data bits, odd parity, 1 stop...
Open the catalog to page 17