Open the catalog to page 1Product Introduction The VTS6D-G is a high-precision industrial-grade sensor developed by RUICOM Technology specifically for the field of vibration and tilt angle measurement. All products undergo rigorous full-temperature-range calibration compensation and stability testing over a certain period before leaving the factory, ensuring exceptional measurement performance under various environmental condition. Equipped with an inbuilt Fast Fourier Transform (FFT) algorithm, it can accurately detect mechanical vibrations within the 0.5~20Hz range, enabling precise calculation of the peak velocity...
Open the catalog to page 2Order Information
Open the catalog to page 4Product Dimensions Shell dimensions: L95×W70×H42mm Suggested screws: 4 M6 screws Measurement Direction
Open the catalog to page 6Function Description of Indicator Light The red work indicator light is always on when powered on and flashes during communication. Legend of Vibration Swing Measurement
Open the catalog to page 7The product includes two protocols: serial communication protocol and MODBUS RTU protocol. The default configuration parameters for the protocols are as follows:_ Default parameters: address 0, baud rate 9600,1 start bit, 8 data, no parity, 1 stop bit. Valid setting address: 0~254; Data length: the length from data length to checksum (including checksum); Data field: according to the different content and length of the command word changes accordingly; Checksum: The sum of data length, address code, command word and data field, regardless of carry, that is, Sum&0xFF. Note, please read the description...
Open the catalog to page 8sensor reply Each data occupies four bytes, as the data below successively Blue is the X, Y angle and temperature in sequence, parse as the 0x04 command Green is the acceleration data of X, Y, Z in sequence, parse as the 0X14 command Orange is the X, Y, Z vibration frequency data in sequence, and parse as the 0X14 command Red is X, Y, Z vibration velocity data in sequence, and parse as 0X14 command Cyan is the X, Y, Z vibration displacement data in sequence, and parse as the 0X14 command Set relative/absolute zero: Data field (1 byte) The current angle can be set to 00:absolute zero 01:relative...
Open the catalog to page 10XX module address, the address ranges from 00 to EF. Note: All products have a common address: FF, if you forget the set address during operation, you can use the FF address to operate the product. The default address of the sensor is 00; 1. If multiple sensors are connected to a set of buses at the same time, such as RS485. Each sensor needs to be set to a different address to achieve separate control and response angles. 2. If the new address is successfully changed, all subsequent commands and the address code in the response packet must be changed to the new address code to take effect, otherwise...
Open the catalog to page 11Example of reading measurement data commandl: Slave response Note: The data field of the slave reply frame is composed of 50H, 46H, 00H, 00H, 23H, 20H, 00H, 00H, 03H, and 57H The X-axis represents the 1st to 4th bytes of the data field, while the Y-axis represents the 5th to 8th bytes, with the lower bytes preceding. The angle is represented using a point system, where one point corresponds to 0.0001°. The angle is calculated as 0.0001 x (point count - offset). For example, if the measurement range is ±10°, there are a total of 200,000 points. Therefore, 0 corresponds to -10°, 200,000 corresponds...
Open the catalog to page 14Note: 0012H is the register address, which controls the sensor baud rate. In the above example, the baud rate of the sensor is set to 19200, and the last two bytes are the CRC checksum.
Open the catalog to page 158.Set the parity bit of the sensor serial port: (factory default is even parity)
Open the catalog to page 16Set sensor latitude command example: Note: 0014H is the register address, this register controls the sensor latitude. In the above example, 1120H is converted to decimal 4384, and then multiplied by a factor of 0.01 to get 43.84°, that is, the sensor latitude is set to 43.84°, and the last two bytes are the CRC checksum. 11 .Set the sensor filter length: Set sensor filter length command example: Note: 000EH is Register Address, which controls the filter length of the sensor. In the above example, the sensor filter length is set to 32, and the last two bytes are the CRC checksum. Note: After setting...
Open the catalog to page 17