1. Catalogs
  2. Shenzhen Ruicom Technology Co., Ltd.
  3. RUICOM SWR34X SWR34D Tilt Switch Tilt Sensor

RUICOM SWR34X SWR34D Tilt Switch Tilt Sensor

RUICOM SWR34X  SWR34D Tilt Switch Tilt Sensor

RUICOM SWR34X SWR34D Tilt Switch Tilt Sensor

Product catalog summary
Product Introduction
The SWR34X/SWR34D series are digital single-axis and dual-axis tilt switches designed for horizontal safety alarming and platform leveling detection. They feature customizable tilt alarm thresholds and built-in relay outputs to control solenoid valves for hydraulic leveling. These devices offer temperature and linearity compensation, and protection against electrical issues, making them suitable for harsh industrial environments.

Application Scope
This series is applicable in various industrial-grade applications, including agricultural machinery, construction equipment, aerial work platforms, woodworking machinery, medical equipment leveling, and electric vehicle control systems.

Technical Highlights
  • Accuracy: 0.1°
  • Relay output (NO/NC)
  • Threshold setting via RS232
  • User-configurable alarm angle

Performance Parameters
  • Measurement range: ±15°
  • Resolution: 0.05°
  • Measurement accuracy: 0.1°
  • Long-term stability: 0.05°
  • Temperature coefficients: Zero-point ±0.006 °/℃, Sensitivity ≤100 ppm/℃
  • Startup time: 0.1s, Response time: 0.2s
  • EMC: EN 61000 and GB/T 17626 compliant
  • MTBF: ≥98,000 hours
  • Shock resistance: 100g @ 11ms
  • Vibration resistance: 10grms, 10–1000Hz
  • Waterproof rating: IP67/IP65

Ordering and Selection
Models are defined by measurement axis, output type, and angular threshold. The factory default alarm threshold is ±2°, customizable per customer requirements.

Interface Definition
Defines wire color functions for different models, including power supply, GND, RXD, TXD, and signal outputs. RXD and TXD lines allow configuration of alarm thresholds via software.

Instructions for Use
Illustrates the operating principle of the dual-axis switch and how to set relative angles. The product can be mounted horizontally or vertically, with specific installation guidelines provided.

Debugging Software
Users can modify alarm thresholds using serial port debugging software. Steps include launching the software, selecting the COM port, and entering commands to set thresholds.

Communication Protocol
Details the data frame format and configuration commands for setting alarm points and zero points. Commands are case-sensitive and include options for setting relative and absolute angles.
See more

Catalog excerpts

RUICOM SWR34X  SWR34D Tilt Switch Tilt Sensor-1

SWR34X/SWR34D Single/Dual-Axis Inclinometer Switch with Relay Output Product Manual V1.5-20260412

 Open the catalog to page 1
RUICOM SWR34X  SWR34D Tilt Switch Tilt Sensor-2

Dynamic Sensing • Precision Measurement and Control [v> Technical Highlights ❖ Accuracy: 0.1°; ❖ Relay output (NO/NC); ❖ User-configurable alarm angle. The SWR34X / SWR34D series consists of digital single-axis and dual-axis tilt switches developed by Ruicom Technology specifically for horizontal safety alarming and platform leveling detection; they feature built-in relay outputs. Users can customize tilt alarm thresholds; when the tilt exceeds the limit, the device outputs a passive relay contact signal (1A drive current) to control solenoid valves for hydraulic outrigger leveling. These switches...

 Open the catalog to page 2
RUICOM SWR34X  SWR34D Tilt Switch Tilt Sensor-3

Dynamic Sensing • Precision Measurement and Control Performance Parameters

 Open the catalog to page 3
RUICOM SWR34X  SWR34D Tilt Switch Tilt Sensor-4

Ordering and Selection Model Output Type Output direction Angular threshold NO:Relay normally open output Output Angle Threshold Setting Any value within the 0-30° NC:Relay normally range can be selected. closed output Examples: 005 = 0.5° alarm; Example: SWR34X1 -NO-005: X-axis, single-channel output, normally open relay output, 0.5° alarm. Note: 1) Different models correspond to different wire color functions, so please refer to the order information and model description before placing an order. 2) The factory default alarm threshold is ±2° (can also be customized according to customer requirements)....

 Open the catalog to page 4
RUICOM SWR34X  SWR34D Tilt Switch Tilt Sensor-5

Dynamic Sensing · Precision Measurement and Control 4) Debugging via laptop requires an RS232-to-USB adapter, whereas a desktop computer can connect directly to the COM port. (If using an adapter, the corresponding driver must be installed.) The diagram above illustrates the operating principle of the dual-axis switch; the output signals are relay-style switch signals. Each output terminal corresponds to an internal switch (indicated within the dashed box), with one side of each switch internally connected to ground. For models equipped with a Common (COM) terminal, the internal switches are...

 Open the catalog to page 5
RUICOM SWR34X  SWR34D Tilt Switch Tilt Sensor-6

Dynamic Sensing • Precision Measurement and ControlProduct Dimensions Housing dimensions: Mounting dimensions: Mounting screws: Note: During installation, ensure the sensor's mounting surface is parallel to the target surface and minimize the effects of dynamic forces and acceleration on the sensor. This product can be mounted either horizontally or vertically; please refer to the diagram below for installation methods.

 Open the catalog to page 6
RUICOM SWR34X  SWR34D Tilt Switch Tilt Sensor-7

Dynamic Sensing • Precision Measurement and ControlDebugging software- If customers wish to modify the alarm thresholds themselves, they can do so by connecting the device to a computer and using serial port debugging software. While standard, publicly available serial debugging tools downloaded from the internet can be used, Ruiguan also provides dedicated debugging software that allows for direct connection to the inclinometer on a PC to display angle readings. Debugging steps: 2) Select the appropriate COM port (refer to item "2"). 3) Use default settings for all other parameters; no further...

 Open the catalog to page 7
RUICOM SWR34X  SWR34D Tilt Switch Tilt Sensor-8

Dynamic Sensing · Precision Measurement and Control installed. f) Use a multimeter to measure the sensor current; if it is below 20mA or above 60mA, the sensor is likely damaged. Communication protocol One: Data frame format: (8 data bits, 1 stop bit, no parity, default baud rate 9600) Angle output format (ASCII code) A single set of output data consists of 18 bytes: Byte1:X Tens digit of the axis angle value Units digit of the axis angle value Byte 14: Decimal point "." Tenths digit of the axis angle value Hundredths digit of the axis angle value Byte 17: Carriage return (0x0D) Byte9:Space(0x20)...

 Open the catalog to page 8
RUICOM SWR34X  SWR34D Tilt Switch Tilt Sensor-9

Dynamic Sensing · Precision Measurement and Control upon receiving the command. When the green wire functions as the zero-reset line, short-circuiting it with the black wire for 2 seconds and then releasing it sets the current angle as the relative zero point. This function operates similarly to the "&Z" command; however, unlike the command, successfully setting the zero point this way triggers an alarm signal output lasting approximately 1 second. (When not using this function, please properly secure the green wire to prevent accidental short-circuits with other wires.) Web: www.ruicomtech.com...

 Open the catalog to page 9

All Shenzhen Ruicom Technology Co., Ltd. catalogs and technical brochures

*Prices are pre-tax. They exclude delivery charges and customs duties and do not include additional charges for installation or activation options. Prices are indicative only and may vary by country, with changes to the cost of raw materials and exchange rates.
About DirectIndustry