Product Introduction
The STS standard output tilt sensor by RUICOM Technology is designed for industrial automation control. It features a compact design with RS485/RS232 communication interfaces, a high-performance MEMS tilt sensing unit, and a 24-bit high-precision differential A/D converter. It uses a fifth-order digital filtering algorithm for precise horizontal and pitch angle measurements, making it suitable for high-precision industrial measurement applications.
Application Field
This sensor is ideal for building structural health monitoring, industrial automation control systems, and industrial sites requiring long-term stable monitoring in high-precision angle measurement applications.
Technical Characteristics
  • Single/dual-axis measurement
  • Measurement range: ±180°
  • Accuracy: 0.01°
  • Industrial-grade reliability
  • Multiple standard output interfaces
Specifications
  • Power supply voltage: 9-36 V
  • Operating temperature: -40 to +85 ℃
  • Measurement range: ±10° to ±180°
  • Resolution: 0.001°
  • Accuracy: MAXE 0.01° to 0.02°
  • Response frequency: 20 Hz
  • Output signal: TTL/RS232/RS485
  • Waterproof rating: IP67
Ordering and Selection
Models are defined by axis, range, output protocol, and installation direction. Example: STS6X10-TTLSP-H indicates X-axis, ±10° range, TTL signal output, serial communication protocol, horizontal installation.
Indicator Light Operation
The red indicator light remains on after power-on. It flashes when a connection is established and data is transmitted. Continuous light indicates a connection failure.
Connection Installation
The sensor uses an M12 interface and supports a 9-36V power supply. It comes with a standard 2m M12-5 core cable.
Interface Definition
Pin definitions include power supply, communication lines, and ground.
Serial Communication Protocol
Data frame format includes identifier, data length, address code, command word, data domain, and checksum. Commands include reading angles, setting zero points, and adjusting communication speed.
MODBUS Communication Protocol
Follows RTU mode with a baud rate of 9600 bps. Commands include reading angle data and setting sensor zero points. The protocol requires specific timing and command sequences for reliable operation.
Sensor Output Control
The document describes the control of sensor output, which can be set to either relative zero or absolute zero. The register address for this control is 0010H. If the value is nonzero (e.g., 00FFH), the output is relative zero; if zero, it is absolute zero. The last two bytes in the command are a CRC checksum.
Set Sensor Address
The process to set a sensor address involves sending a command twice for validation. The register address for setting the sensor address is 0011H. An example command changes the sensor address to 0004H, with the last two bytes being the CRC checksum.
Set Sensor Baud Rate
The default baud rate is 9600bps, and it can be changed using a specific command sent twice for validation. The register address for baud rate control is 0012H. Baud rates can be set to 4800, 9600, 19200, 38400, or 115200 bps, with corresponding hexadecimal values. An example sets the baud rate to 19200bps.
Set Sensor Communication Character Format
The character format of sensor communication can be set using a command sent twice for validation. The register address for this setting is 0009H. The format options include a start bit + 8 data bits with or without parity + 1 stop bit. The factory default is even parity, but it can be changed to no parity as shown in the example.
Contact Information
For further assistance, contact details are provided, including a website, email, phone number, and physical address.
See more

Catalog excerpts

RUICOM STS Standard Output Tilt Sensor-1

STS STANDARD OUTPUT TILT SENSOR Product manual V1.1-20250226

 Open the catalog to page 1
RUICOM STS Standard Output Tilt Sensor-2

Technical Characteristics ❖ Extra-wide measurement range: ±180°; ❖ Excellent measurement accuracy0.01° (full range); ❖ Industrial-grade reliability design; ❖ Meets the requirements for demanding industrial environments; ❖ Multiple standard output interfaces facilitate system integration and expansion. Product Introduction- The STS standard output tilt sensor is a product developed by RUICOM Technology, focusing on the field of industrial automation control. This product features a compact industrial design. Equipped with RS485/ RS232 standard serial communication interfaces. It integrates a high-performance...

 Open the catalog to page 2
RUICOM STS Standard Output Tilt Sensor-3

Power supply voltage Operating current Operating temp Storage temp

 Open the catalog to page 3
RUICOM STS Standard Output Tilt Sensor-5

Product Dimensions Mounting Surface Horizontal InstaNation Mounting Surface Horizontal Downward Installation

 Open the catalog to page 5
RUICOM STS Standard Output Tilt Sensor-6

Vertical Left Installation Install vertically to the right

 Open the catalog to page 6
RUICOM STS Standard Output Tilt Sensor-7

Serial communication protocol I. Data Frame Format : ( 8 data bits), 1 stop bit No verification (Default speed 9600) Data format: Hexadecimal; Data length: From data length to checksum (including checksum) Length; Address code: Address of the acquisition module. The default value is 00; The data field changes accordingly based on the different contents and lengths of the command word; Checksum: The sum of data length, address code, command word, and data field does not consider carry. II. Command Word Parsing__ Simultaneously read X and Y angle 0X04 commands Sensor response reply Set relative/absolute...

 Open the catalog to page 7
RUICOM STS Standard Output Tilt Sensor-8

0X8C Set sensor output mode Response system: The upper computer needs to send a command to read the angle before the sensor responds to the relative angle. Automatic output system: After the sensor is powered on, it automatically outputs X and Y angles, and the output frequency is set as shown in the table on the right. (This function can provide power-off memory) results of the sensor response 00 Success FF Failure 00 represents the response format (default value) 01 represents 5Hz automatic output mode 02 represents 15Hz automatic output mode 03 represents 25Hz automatic output mode 04 represents...

 Open the catalog to page 8
RUICOM STS Standard Output Tilt Sensor-9

results of the sensor response 00 represents absolute zero point 01 represents relative zero point You must first enter the settings mode before entering and saving the settings 1. Enter settings mode ^ Send command: 68 04 00 51 55 A Set address code B Set baud rate C Set calibration parameters D Automatic or inquiry mode E Relative zero point 3. Save parameters and write all parameters to FLASH ^ Send command: 68 04 00 53 57. 4. Exit the setting mode ^ Send command: 68 04 00 52 56.

 Open the catalog to page 9
RUICOM STS Standard Output Tilt Sensor-10

Please read the following items carefully before use: 1 > Because of the MODBUS protocol stipulates between the two data frames should be at least more than 3.5 bytes of time (such as the baud rate of 9600, the time is 3.5 X (1 /9600) X 11 =0.004s). However, in order to leave enough margin, the sensor will be increased this time to 10ms, so please leave at least of the time interval between each data frame. 2> MODBUS protocol stipulates the broadcast address----0 relevant content, the sensor can also accept the broadcast address content, but will not reply. Therefore, the broadcast address 0...

 Open the catalog to page 10
RUICOM STS Standard Output Tilt Sensor-12

Note: 0010 is the register address, the register control sensor output is relative zero, or absolute zero. If nonzero (as in the example above, is written to 00FFH), the output is relative zero. On the contrary, if zero (Change the 5th and 6th bytes to 00H), is the absolute zero. The last two bytes are CRC checksum. Note: 0012H is the register address, which controls the baud rate of the sensor. In the above example, the baud rate of the sensor is set to 19200, and the last two bytes are CRC checksum.

 Open the catalog to page 12
RUICOM STS Standard Output Tilt Sensor-13

4. SET SENSOR COMMUNICATION CHARACTER FORMAT The above example is to set the byte format to: a start bit + 8 data bits without parity + 1 stop bit It is valid after power on again. The factory default is a start bit + 8 data bits, even parity + 1 stop bit Note: 0009 is the register address, which controls the character format of the sensor communication. 0000H: one start bit + 8 data bits, even parity + 1 stop bit 0001H: one start bit + 8 data bits without parity + 1 stop bit Web: www.ruicomtech.com E-mail: [email protected] Add:Building 1, Lixin Lake Creative Park, 1 Furui Rd, Fuhai St, Bao'an,...