Product Introduction: The NTS3 series tilt sensor by RUICOM is a compact MEMS single-axis sensor designed for applications with space and cost constraints. It offers excellent linear current output after internal corrections, supports long-distance signal transmission up to 2000 meters, and is resistant to electromagnetic interference and shock, making it ideal for harsh industrial environments. It provides real-time tilt angle output without the need for calibration between surfaces, suitable for static and slow dynamic angle measurements.

Application Scope: The sensor is used in engineering machinery angle control, medical bed leveling, gimbal operation monitoring, satellite antenna positioning, automobile four-wheel alignment, and chassis measurement.

Technical Highlights: The sensor outputs 4~20mA, with a selectable measuring range of ±10° to ±90°, accuracy of 0.1°, and operates in temperatures from -40 to +85℃. It requires a DC9~36V power supply.

Performance Parameters: The sensor offers various measurement ranges (±30° to 360°), with a resolution of 0.02° to 0.08° and accuracy of 0.1° to 0.2° at 25℃. It has a long-term stability of less than 0.5°, a zero temperature coefficient of ±0.02°/℃, and a sensitivity temperature coefficient of ≤150 ppm/℃. It is compliant with EN61000 and GBT17626 standards, has an IP67 waterproof rating, and can withstand shocks of 100g and vibrations of 10grms.

Ordering and Selecting: The model can be customized based on housing, axis, range, signal output, and installation method. For example, NTS3X10-A1-H indicates a shell housing, X-axis, ±10° range, 4~20mA output, and horizontal installation.

Electrical Parameters: The sensor operates with a supply voltage of 9 to 36V, an operating current of 12mA, and supports resistive and capacitive loads.

Interface Definition: The sensor uses a color-coded wiring system for power supply and output currents, with specific pin definitions for connections.

Product Dimensions: The PCBA board measures L33 × W27 × H8.2 mm, while the shell dimensions are L55.5×W37×H29mm, made of anodized aluminum.

Installation Orientation: The sensor should be mounted parallel to the target surface, minimizing dynamic and acceleration effects. It can be installed horizontally or vertically.

See more

Catalog excerpts

Ruicom NTS3 Series Current Output Tilt Sensor-2

Technical Highlights ❖ Measuring range: ±10°~±90° selectable; ❖ Wide operating temperature range: -40 ~+85°C; Product Introduction- The NTS3 series tilt sensor, developed by RUICOM, is a small-sized MEMS single-axis tilt sensor. Its output current, after internal double linearity correction, exhibits excellent linear current output characteristics, primarily targeting applications with specific requirements for installation space and cost. This product integrates a tilt sensing unit based on microelectromechanical technology, is compact in size, supports long-distance signal transmission (up...

 Open the catalog to page 2
Ruicom NTS3 Series Current Output Tilt Sensor-3

Performance Parameters Angle output calculation formula Angle = (Output Current - Zero-Point Current) + Angle Sensitivity Angle Sensitivity = Output Current Range + Angle Measurement Range Example: NTS3X10-V1 -H (±10° Measurement Range 4 ~20mA Output Current Range) Angle Sensitivity=(20-4M + 10°-(-10°))= 1 6+20=0.8 mA/°

 Open the catalog to page 3
Ruicom NTS3 Series Current Output Tilt Sensor-5

Product Dimensions PCBA Board Dimensions PCBA board dimensions: L33 × W27 × H8.2 mm Recommended screws: 4 × M3 screws Package dimensions Shell dimensions: L55.5×W37×H29mm Shell material: anodized aluminum Connector: aviation plug 12G-5P Suggested screws: 3 M4 screws

 Open the catalog to page 5
Ruicom NTS3 Series Current Output Tilt Sensor-6

Installation Orientation During installation, the sensor mounting surface should be kept parallel to the target surface, and the effects of dynamics and acceleration on the sensor should be minimized. This product can be installed horizontally or vertically; please refer to the diagram below for installation instructions: Web: www.ruicomtech.com E-mail: [email protected] Tel: 0755-23087719 After-sales technical support:+86 183 0761 1639 Add:Building 1, Lixin Lake Creative Park, 1 Furui Rd, Fuhai St, Bao'an, Shenzhen China

 Open the catalog to page 6

All Shenzhen Ruicom Technology Co., Ltd. catalogs and technical brochures

*Prices are pre-tax. They exclude delivery charges and customs duties and do not include additional charges for installation or activation options. Prices are indicative only and may vary by country, with changes to the cost of raw materials and exchange rates.
About DirectIndustry
DirectIndustry is a marketplace that offers B2B players a complete experience, from product sourcing to purchase. DirectIndustry is an entity of VirtualExpo Group.