SDA126T-CAN2.0B Dynamic Dual axis Inclinometer
9Pages

{{requestButtons}}

Catalog excerpts

SDA126T-CAN2.0B Dynamic Dual axis Inclinometer - 1

SDA126T- CAN2.0B Dynamic dual axis inclinometer SPECIFICATIONS Item No.:SDA126T-CAN2.0B Desc.:CAN2.0B Dynamic Dual axis Inclinometer Production implementation standard reference ● Enterprise quality system standards: ISO9001: 2008 standard (certification number: 128101) ● Tilt sensor production standards: GB / T 191 SJ 20873-2003 inclinometer general specification of Level ● The Academy of metrology and quality inspection Calibrated in accordance to: JJF1119-2004 Electronic Level calibration Specification ● Gyro accelerometer test standard: QJ 2318-92 Gyro accelerometer test methods ● Software development reference standard: GJB 2786A-2009 military software development General requirements ● Product environmental testing standards: GJB150 ● Electromagnetic anti-interference test standards: GB / T 17626 ● Version:Ver.0

Open the catalog to page 1
SDA126T-CAN2.0B Dynamic Dual axis Inclinometer - 2

SDA126T- CAN2.0B Dynamic dual axis inclinometer General Description SDA126T is a CAN 2.0B output dual-axis dynamic inclinometer newly developed by RION’s D & R for the industrial field control , the product can be used in the fast moving car construction machinery, Compared to static tilt switch can anti acceleration effect,using industry standard isolated CAN transceiver, built-in high-precision A / D differential converter, by 5 filtering algorithm, which can measure the angle of sensor output relative to the horizontal tilt and pitch tilt. Because of Built in ADI company’s high precision...

Open the catalog to page 2
SDA126T-CAN2.0B Dynamic Dual axis Inclinometer - 3

SDA126T- CAN2.0B Dynamic dual axis inclinometer Ordering information: Parameters C *This Technical data only list ± 10 °, ± 30 °, ± 60 °, + 90 ° series for reference, other measuring range

Open the catalog to page 3
SDA126T-CAN2.0B Dynamic Dual axis Inclinometer - 4

SDA126T- CAN2.0B Dynamic dual axis inclinometer please refer to the adjacent parameters Resolution: Refers to the sensor in measuring range to detect and identify the smallest changed value. Absolute accuracy: Refers to in the normal temperature circumstances,the sensor absolute linearity, repeatability, hysteresis, zero deviation, and transverse error comprehensive error. Long term stability : Refers to the sensors in normal temperature conditions, the deviation between the maximum and minimum values after a year's long time work. Response time: Refers to the sensor in an angle change, the...

Open the catalog to page 4
SDA126T-CAN2.0B Dynamic Dual axis Inclinometer - 5

SDA126T- CAN2.0B Dynamic dual axis inclinometer Dimension Measuring Directions&Fix The installation must guarantee the product bottom is parallel to measured face, reduce the influence and of dynamic and acceleration to the sensor. This product can be installed horizontally or mounted vertically (mounted vertically selection is only applicable to the single axis), for installation please refer to the following scheme. Production installation notes: Please follow the correct way to install tilt sensor, incorrect installation can cause measurement errors, with particular attention to the...

Open the catalog to page 5
SDA126T-CAN2.0B Dynamic Dual axis Inclinometer - 6

SDA126T- CAN2.0B Dynamic dual axis inclinometer Electrical Connection Line color function Power Negative Power Positive Rion products’ communication protocol communication protocol: 1): Revise node number,ID byte wide is 29, default node number is 0x05 CAN-ID Fourth byte Fifth byte Third byte Sixth byte Eighth byte Table 1-3 request message format Third byte Fourth byte Fifth byte Sixth byte Eighth byte Table 1-4 response message for

Open the catalog to page 6
SDA126T-CAN2.0B Dynamic Dual axis Inclinometer - 7

SDA126T- CAN2.0B Dynamic dual axis inclinometer Remark: if controller send CAN-1 D=0x600+0x05, sended data: 40 10 10 00 10 00 00 00 Transducer return CAN-1 D=0x580+0x05 ( default) , returned data- 40 10 10 00 10 00 00 00, received frame after restarting ID is 0x590(0x580+0x10), the data represent successful modification of frame ID. 2) CAN baud rate setting CAN-ID followed by 8 bytes parameter, previous 3 bytes is forX axis, the followed 3 bytes is for Y axis, lower bytes are at the front part, the higher bytes are at the behind part. Example for angle convert: Angle data of X axis is...

Open the catalog to page 7
SDA126T-CAN2.0B Dynamic Dual axis Inclinometer - 8

SDA126T- CAN2.0B Dynamic dual axis inclinometer XH XL 0x15 0x26 4) Output rate setting ( Factory default output 0x06: 25Hz ) Freq: 0x00: close output; 0x04:15Hz; 0x08: 50Hz; >=KMore products information, please refer to the company's Website : www.rion-tech.net (Note: product functions, parameters and appearance will be adjusted as the technology is upgraded, please confirm with the pre-sales business contact before purchase.)

Open the catalog to page 8
SDA126T-CAN2.0B Dynamic Dual axis Inclinometer - 9

Ri0n CHI NA SHENZHEN RION TECH NO LOGY CO., LTD. •INCLINOMETER ‘TILT SWITCH ‘ACCESSORIES ‘NORTH FINDER ‘TURNTABLE •ELECTRONIC COMPASS ‘DIGITAL INCLINOMETER ‘ACCELEROMETER •ATTITUDE AND HEADING REFERENCE SYSTEM ‘ELECTRONIC GYROSCOPE T : (86) 755-29657137 F : (86) 755-29123494 W : www.riontech.cn E : sales@rion-tech.net A: Block 1, COFCO(FUAN) Robotics Industrial Park , Da Yang Road 90, Fuyong Distict, Shenzhen City, China

Open the catalog to page 9

All SHENZHEN RION TECHNOLOGY CO. catalogs and technical brochures

  1. AH200C MEMS

    18 Pages

  2. RION ACA2000T

    11 Pages