SDA118T/SDA128T Dynamic-Static Dual Mode Inclinometer - 1

SDA118T/SDA128T-Dynamic-Static Dual Mode Inclinometer SPECIFICATIONS Model Number: SDA118T/SDA128T Description: Dynamic-Static Dual Mode Inclinometer Production implementation standard reference • ISO9001:2008 ( Certificate no.: 128101 ) •CE:AT011611741E FCC:AT011611742E • Tilt sensor production standards: GB / T 191 SJ 20873-2003 inclinometer general specification of Level • The Academy of metrology and quality inspection Calibrated in accordance to: JJF1119-2004 Electronic Level calibration Specification • Gyro accelerometer test standard: QJ 2318-92 Gyro accelerometer test methods •Software development reference standard: GJB 2786A-2009 military software development General requirements • Product environmental testing standards: GJB150 • Electromagnetic anti-interference test standards: GB / T 17626 • Version: Ver.01 • Date:: 201 7.09.15

Open the catalog to page 1
SDA118T/SDA128T Dynamic-Static Dual Mode Inclinometer - 2

SDA118T/SDA128T-Dynamic-Static Dual Mode Inclinometer Description The SDA118T/SDA128T is an industrial grade current output inclinometer with integrated dynamic and static dual mode combination algorithm. According to different working conditions, the product automatically switches between dynamic and static measurement modes. High-precision measurement of products is guaranteed in a variety of work environments. When the working environment is in static mode, the inclinometer will adopt a static algorithm inside. When the working environment is in dynamic mode, the dynamic algorithm will...

Open the catalog to page 2
SDA118T/SDA128T Dynamic-Static Dual Mode Inclinometer - 3

SDA118T/SDA128T-Dynamic-Static Dual Mode InclinometerApplication • Satellite antenna search star • Rail-mobile monitoring •Tilt angle measurement of High-altitude construction machinery •oil-well drilling equipment • Radar detection of vehicle platform •Underground drill posture navigation • Based on the angle direction measurement •Shield pipe jacking application •Geological equipment inclined monitoring •Gun Barrel angle measurement in early shooting •Satellite communications vehicle posture detection •Ship’s navigation posture measurement E.g- SDA128T-10-A1: dual axis / standard...

Open the catalog to page 3
SDA118T/SDA128T Dynamic-Static Dual Mode Inclinometer - 4

SDA118T/SDA128T-Dynamic-Static Dual Mode Inclinometer stability *This Technical data only list ± 10 °, ± 30 °, ± 60 °, + 90 ° series for reference, other measuring range please refer to the adjacent parameters. Resolution: It means that the sensor can detect and distinguish the smallest change value measured within the measurement range. Absolute Accuracy: Absolute accuracy is the combined error of the sensor's absolute linearity, repeatability, hysteresis, zero offset, and horizontal axis error at ambient temperature. Long-term stability: Long-term stability refers to the deviation between...

Open the catalog to page 4
SDA118T/SDA128T Dynamic-Static Dual Mode Inclinometer - 5

SDA118T/SDA128T-Dynamic-Static Dual Mode Inclinometer Mechanical Parameters o Connectors: 1m lead cable (customized) o Protection glass: IP67 o Enclosure material : Aluminum alloy sanding o Installation : 3*M4 screws Working Principle Adopt the European import of core control unit, using the capacitive micro pendulum principle and the earth gravity principle, when the the inclination unit is tilted, the Earth's gravity on the corresponding pendulum will produce a component of gravity, corresponding to the electric capacity will change, , by enlarge the amount of electric capacity ,...

Open the catalog to page 5
SDA118T/SDA128T Dynamic-Static Dual Mode Inclinometer - 6

SDA118T/SDA128T-Dynamic-Static Dual Mode Inclinometer SIZE Angle output calculation formula Angle = (output current - zero position current)÷angle sensitivity Angle sensitivity = output current range ÷ angle measurement range Example: SDA118T-SDA128T-30-A1 ( ± 30 ° measurement range 16mA output current range) Angle sensitivity = 16÷60=0.266666 mA

Open the catalog to page 6
SDA118T/SDA128T Dynamic-Static Dual Mode Inclinometer - 7

SDA118T/SDA128T-Dynamic-Static Dual Mode Inclinometer Installation Install the sensor mounting surface parallel to the target surface to be measured and reduce the effects of dynamics and acceleration on the sensor. This product can be installed horizontally or vertically. Please refer to the following diagram for the installation method: Note: horizontal installation is factory default, if need vertical installation, please confirm with sales. Horizontal install Vertical install

Open the catalog to page 7
SDA118T/SDA128T Dynamic-Static Dual Mode Inclinometer - 8

SDA118T/SDA128T-Dynamic-Static Dual Mode Inclinometer Production Installation Notes: Please follow the correct way to install tilt sensor, incorrect installation can cause measurement errors, with particular attention to the "surface", "line":: 1) The Sensor mounting surface and the measured surface must be fixed closely, smoothly, stability,if mounting surface uneven likely to cause the sensor to measure the angle error. See Figure Pic.AB 2) The sensor axis and the measured axis must be parallel ,the two axes do not produce the angle as much as possible. See Figure Pic.CD Electrical...