SCA128T- Current Type Dual-Axis Inclinometer SPECIFICATIONS Item No.SCA128T Description: Current Type Dual-Axis Inclinometer Production implementation standard reference ● Enterprise quality system standards: ISO9001: 2008 standard (certification number: 128101) ● Tilt sensor production standards: GB / T 191 SJ 20873-2003 inclinometer general specification of Level ● The Academy of metrology and quality inspection Calibrated in accordance to: JJF1119-2004 Electronic Level calibration Specification ● Gyro accelerometer test standard: QJ 2318-92 Gyro accelerometer test methods ● Software development reference standard: GJB 2786A-2009 military software development General requirements ● Product environmental testing standards: GJB150 ● Electromagnetic anti-interference test standards: GB / T 17626 ● VersionVer.09 ● Date:2014.4.22

Open the catalog to page 1
SCA128T current output inclinometer/tilt measurement - 2

SCA128T- Current Type Dual-Axis Inclinometer General Description SCA128T is a standard industrial output dual-axis inclinometer, standard current 4 ~ 20mA output, meanwhile output dual axis inclination,can be long-distance transmission of up to 2000 meters. The output signal with strong anti-interference, professional be used to work on engineering machinery and equipment in harsh environment. The product uses the latest MEMS sensor production technology for production, made precise compensation and correction to temperature error and nonlinearity error, small measuring range the highest...

Open the catalog to page 2
SCA128T current output inclinometer/tilt measurement - 3

SCA128T- Current Type Dual-Axis Inclinometer Electronic Characteristics Parameters Power supply Working current Output overload Working temperature Store temperature Technical Data Parameters range Measuring axis Zero output Response time accuracy Long term stability Zero temperature coefficient Sensitivity temperature coefficient frequency Electromagneti Insulation Resistance Anti-vibration Protection glass Cables Standard 1M length、wearproof、grease proofing、wide temperature、 Shielded cables4*0.4mm2 * This Technical data only list ± 10 °, ± 30 °, ± 60 °, + 90 ° series for reference, other...

Open the catalog to page 3
SCA128T current output inclinometer/tilt measurement - 4

SCA128T- Current Type Dual-Axis Inclinometer Resolution: Refers to the sensor in measuring range to detect and identify the smallest changed value. Absolute accuracy: Refers to in the normal temperature circumstances,the sensor absolute linearity, repeatability, hysteresis, zero deviation, and transverse error comprehensive error. Long term stability : Refers to the sensors in normal temperature conditions, the deviation between the maximum and minimum values after a year's long time work. Response time: Refers to the sensor in an angle change, the sensor output value reached the standard...

Open the catalog to page 4
SCA128T current output inclinometer/tilt measurement - 5

SCA128T- Current Type Dual-Axis Inclinometer Angle output computational formula Angle = (Output current—ZERO position current)* Angle sensitivity Angle sensitivity= Output current range* Angle measuring range E.g: SCA128T-30TA1 (±30° Measuring range 16mA Output current range) Production installation notes: Please follow the correct way to install tilt sensor, incorrect installation can cause measurement errors, with particular attention to the "surface", "line":: 1) The Sensor mounting surface and the measured surface must be fixed closely, smoothly, stability,if mounting surface uneven...

Open the catalog to page 5
SCA128T current output inclinometer/tilt measurement - 6

SCA128T- Current Type Dual-Axis Inclinometer Measuring Directions&Fix The installation must guarantee the product bottom is parallel to measured face, and reduce the influence of dynamic and acceleration to the sensor. This product can be installed horizontally or mounted vertically (mounted vertically selection is only applicable to the single axis), for installation please refer to Electrical Connection Ordering information: —■ 1 ] Standard shell sealed without shell E.g: SCA128T-10-A1: Dual-axis/Standard/±10° Measuring range /4-20mAOutput current fSOSfssJnt Device >=KMore information...

Open the catalog to page 6
SCA128T current output inclinometer/tilt measurement - 7

CHINA SHENZHEN RION TECHNOLOGY CO.,LTD.

Open the catalog to page 7

All SHENZHEN RION TECHNOLOGY CO. catalogs and technical brochures

  1. AH200C MEMS

    18 Pages

  2. RION ACA2000T

    11 Pages