SCA118T standard single axis inclinometer current output/Equipment level control
8Pages

{{requestButtons}}

Catalog excerpts

SCA118T standard single axis inclinometer current output/Equipment level control - 1

SCA118T- Current Type Single-Axis Inclinometer SPECIFICATIONS Item No.SCA118T Description: Current Type Single-Axis Inclinometer Production implementation standard reference ● Enterprise quality system standards: ISO9001: 2008 standard (certification number: 128101) ● Tilt sensor production standards: GB / T 191 SJ 20873-2003 inclinometer general specification of Level ● The Academy of metrology and quality inspection Calibrated in accordance to: JJF1119-2004 Electronic Level calibration Specification ● Gyro accelerometer test standard: QJ 2318-92 Gyro accelerometer test methods ● Software development reference standard: GJB 2786A-2009 military software development General requirements ● Product environmental testing standards: GJB150 ● Electromagnetic anti-interference test standards: GB / T 17626 ● VersionVer.09 ● Date:2014.4.22

Open the catalog to page 1
SCA118T standard single axis inclinometer current output/Equipment level control - 2

SCA118T- Current Type Single-Axis Inclinometer General Description SCA118T is a standard industrial output single-axis inclinometer, standard current 4 ~ 20mA output, can be long-distance transmission of up to 2000 meters. The output signal with strong anti-interference, professional be used to work on engineering machinery and equipment in harsh environment. The product uses the latest MEMS sensor production technology for production, made ​​precise compensation and correction to temperature error and nonlinearity error, small measuring range the highest accurate up to 0.03 ° (more...

Open the catalog to page 2
SCA118T standard single axis inclinometer current output/Equipment level control - 3

SCA118T- Current Type Single-Axis Inclinometer Technical Data Parameters range Measuring axis Zero output accuracy Long term stability Zero temperature coefficient Sensitivity temperature coefficient time Response frequency response Electromagnet Insulation Resistance glass Cables Standard 1M length、wearproof、grease proofing、wide temperature、 Shielded cables4*0.4mm2

Open the catalog to page 3
SCA118T standard single axis inclinometer current output/Equipment level control - 4

SCA118T- Current Type Single-Axis Inclinometer * This Technical data only list ± 10 °, ± 30 °, ± 60 °, + 90 ° series for reference, other measuring range please refer to the adjacent parameters Electronic Characteristics Resolution: Refers to the sensor in measuring range to detect and identify the smallest changed value. Absolute accuracy: Refers to in the normal temperature circumstances,the sensor absolute linearity, repeatability, hysteresis, zero deviation, and transverse error comprehensive error. Long term stability : Refers to the sensors in normal temperature conditions, the...

Open the catalog to page 4
SCA118T standard single axis inclinometer current output/Equipment level control - 5

SCA118T- Current Type Single-Axis Inclinometer Working Principle Adopt the European import of core control unit, using the capacitive micro pendulum principle and the earth gravity principle, when the the inclination unit is tilted, the Earth's gravity on the corresponding pendulum will produce a component of gravity, corresponding to the electric capacity will change, , by enlarge the amount of electric capacity , filtering and after conversion then get the inclination. UR, U..Respectively is the pendulum left plate and the right plate corresponding to their respective voltage between thee...

Open the catalog to page 5
SCA118T standard single axis inclinometer current output/Equipment level control - 6

SCA118T- Current Type Single-Axis Inclinometer Electrical Connection Line color Power negative Power positive Angle output computational formula Angle = (Output currentZERO position current)÷ Angle sensitivity current current) Angle sensitivity= Output current range÷ Angle measuring range range÷ E.gSCA118T-30-A (±30° Measuring range 16mA Output current range ) E.g SCA118T-30-A1 16mA Angle sensitivity= 16÷60=0.266666 mA/ ° 16÷ mA/° Production installation notes : Please follow the correct way to install tilt sensor, incorrect installation can cause measurement errors, with particular...

Open the catalog to page 6
SCA118T standard single axis inclinometer current output/Equipment level control - 7

SCA118T- Current Type Single-Axis Inclinometer Measuring Directions&Fix_ The installation must guarantee the product bottom is parallel to measured face, and reduce the influence of dynamic and acceleration to the sensor. This product can be installed horizontally or mounted vertically (mounted vertically selection is only applicable to the single axis), for installation please refer to >=KMore information please visit Rion's company website: www.rion-tech.net sales@ rion-tech.net

Open the catalog to page 7
SCA118T standard single axis inclinometer current output/Equipment level control - 8

CHINA SHENZHEN RION TECHNOLOGY CO.,LTD.

Open the catalog to page 8

All SHENZHEN RION TECHNOLOGY CO. catalogs and technical brochures

  1. AH200C MEMS

    18 Pages

  2. RION ACA2000T

    11 Pages