Introduction
The AKG392 is a three-axis MEMS digital vibration sensor designed for applications such as vibration and impact testing. It features digital interface outputs (RS232/485/TTL) and supports multi-point measurement and data analysis through internal FFT processing. The sensor is constructed with a single crystal silicon capacitive sensor, low-power ASIC, microprocessor, and temperature sensor, ensuring low power consumption and stable output.
Main Features
  • Three-axis measurement (X, Y, Z)
  • Output signals: RS232, RS485, TTL
  • Power supply: 9-36V
  • Operating temperature: -40°C to +85°C
  • Size: 34.3×34.3×38.5mm
  • Excellent deviation stability and environmental performance
Applications
  • Medical equipment, bridges, large machinery, engines
  • Automobiles, road rollers, crash records, fatigue monitoring
  • Wind power generation, low-frequency vibration monitoring
  • Traffic system monitoring, roadbed analysis, high-speed railway fault detection
Specifications
  • Measurement range: ±2g to ±40g
  • Bias calibration: <1mg
  • Power on/off repeatability: <2mg
  • Bandwidth: 500Hz
  • Output rate: 5Hz to 1000Hz
  • Protocols: RION 68 and MODBUS RTU
  • Weight: 82g (sensor), 48g (magnetic base), 20g (adapter plate)
Vibration Parameter Index
  • Acceleration: 2g to 40g
  • Frequency: 0 to 500Hz
  • Frequency resolution: 4Hz
Order Instructions
Example: AKG392-02-T-68 indicates RS232 output, ±2g measure range, standard installation, RION 68 protocol.
Mounting Accessories
  • Magnetic base: Stainless steel
  • L-type pinboard: Aluminum alloy
Connection
Thread color functions: GND, RS232/RS485, Vcc 9-36V
Sensitivity and Communication Protocol
The sensor supports RION 68 and MODBUS RTU protocols with default settings including a baud rate of 9600. Communication involves a question and answer format with data checks using checksum or CRC16.
Automatic Data Output
Data output is determined by the automatic output mode command, with options for acceleration, frequency, speed, amplitude, and temperature.
RION 68 Communication Protocol
Data frame format includes identifier, data length, address code, command word, data domain, and checksum. Commands allow reading of acceleration, frequency, speed, amplitude, and setting communication rates and output modes.
Overview
This document provides technical specifications and operational procedures for the AKG392 MEMS Digital Vibration Sensor. It includes instructions for setting sensor parameters, communication protocols, and data interpretation.
Specifications
  • The sensor uses MODBUS RTU protocol with default communication parameters: address 1, baud rate 9600, 1 start bit, 8 data bits, even parity, and 1 stop bit.
  • Effective address range is 1 to 247, and it supports CRC16 data checks.
Procedures
  • Setting Commands: Commands must be sent twice consecutively to be effective. Settings are not saved after power-off unless a save command is issued.
  • MODBUS Protocol: Requires a minimum 10ms interval between data frames. Broadcast address 0 can be used for setting multiple sensors simultaneously.
  • Data Types: Includes short, ushort, int, and uint with specific read-only registers for temperature, acceleration, vibration frequency, speed, and amplitude.
Data Interpretation
  • Data values are calculated by multiplying register data by a coefficient.
  • Example provided for converting acceleration data from hexadecimal to decimal and applying accuracy coefficients.
Commands and Examples
  • Set Sensor Address: Example provided for changing the sensor address with CRC checksum verification.
  • Set Baud Rate: Instructions for setting baud rate with examples for different rates.
  • Set Parity Bit: Command to change parity bit settings, effective after re-powering.
  • Set Output Mode: Command to set sensor output frequency with valid values listed.
  • Set Auto-Output Data: Command to configure automatic data output, requiring consecutive command sending.
  • Read Auto-Output Data: Example provided for reading sensor automatic output data.
  • Set Bandwidth: Command to adjust sensor bandwidth with valid values provided.
Recommendations
  • Ensure commands are sent twice consecutively for settings to take effect.
  • Allow a 10ms interval between data frames to ensure proper communication.
  • Use broadcast address for simultaneous sensor configuration when needed.
See more

Catalog excerpts

Rion Vibration Sensor AKG392-1

AKG392 MEMS DIGITAL Vibration sensor MEMS DIGITAL Vibration sensor

 Open the catalog to page 1
Rion Vibration Sensor AKG392-2

AKG392 MEMS DIGITAL Vibration sensor ○ CE certification: AT18250EC101483 ○ RoHS certification: 18300RC20410801 ○ China National Intellectual Property Appearance Patent (Patent No.: ZL 201830752896.8) ○ Revision time:2026-7-6 Note: Product functions, parameters, appearance, etc. will be adjusted as the technology upgrades. Please contact our pre-sales business to confirm when purchasing. Disclaimer This product is developed exclusively for commercial applications and is prohibited from being used for illegal purposes, such as military activities, research related to nuclear, chemical, or biological...

 Open the catalog to page 2
Rion Vibration Sensor AKG392-3

► INTRODUCTION AKG392 three-axis vibration sensor is a product independently developed and produced, applied in wide range of applications, which covers many fields such as vibration testing and impact testing. The product adopts digital interface output with options as RS232/485/TTL. Different address codes can be set, multiple Vibration sensor can be installed in series for long distance, which is convenient for multi-point measurement and data analysis. Internal FFT processing can directly output the object vibration frequency and speed and Amplitude, convenient for users to analyze data....

 Open the catalog to page 3
Rion Vibration Sensor AKG392-5

AKG392 MEMS DIGITAL Vibration sensor ▶ ORDER INSTRUCTION AKG39 T: Standard installation A: Magnetic adsorption base B: L-type adapter plate Communicating Protocol Installation method Measure range Output signal 68:RION 68 custom protocol MB:MODBUS RTU protocol 40: ±40g E.g: AKG392-02-T-68: RS232 output / ±2g measure range / standard installation / RION 68 protocol.

 Open the catalog to page 5
Rion Vibration Sensor AKG392-6

Magnetic base Material: Stainless steel L-type pinboard Material: aluminum alloy

 Open the catalog to page 6
Rion Vibration Sensor AKG392-7

AKG392 MEMS DIGITAL Vibration sensor ► SENSITIVITY AMPLITUDE-FREQUENCY RESPONSE CHARACTERISTIC CURVE (reference conditions: f=20.000Hz, a=2.000G) ► SENSITIVITY LINEARITY GRAPH The product includes 68 protocol and MODBUS RTU two protocols. The default configuration parameters of the protocol are as follows:__ RION 68 protocol and MODBUS protocol mutual switching method: Open the serial port debugging assistant, select the baud rate 115200, no parity, stop bit 1, the connection port number, make the host computer send hexadecimal 0xAA regularly for every 10ms. Power on the product and reply "RION"...

 Open the catalog to page 7
Rion Vibration Sensor AKG392-8

This output is related to the automatic output mode command. When the corresponding BIT bit is set, it will be output. The lower the BIT, the higher the data content. That is, all content output is sorted from left to right as: acceleration|frequency|speed|amplitude|temperature. for example: 68 protocol: the automatic output item is 1011H, then the automatic output data is: acceleration|frequency|amplitude; Modbus protocol: the automatic output item is 9001H, then the automatic output data is: acceleration|amplitude|temperature.___ The following table describes the relationship between output...

 Open the catalog to page 8
Rion Vibration Sensor AKG392-9

1.DATA FRAME FORMAT:(8 bits date, 1 bit stop, No check, Default baud rate 9600) Default communication parameters: address 0, baud rate 9600, 1 start bit, 8 data, no parity, 1 stop bit; Effective setting address: 0~254; Data length: the length from data length to checksum (including checksum); Data field: according to the different content and length of the command word changes accordingly; Checksum: The sum of data length, address code, command word and data field, regardless of carry, that is, Sum&0xFF. Command Meaning/Example Description 0X01 Read X axis acceleration Data field (0byte) command....

 Open the catalog to page 9
Rion Vibration Sensor AKG392-10

Sensor reply Signed 16-bit integer, big endian, coefficient 0.1 No data field command Data field(6byte) Signed 32-bit integer, big endian, coefficient 0.000001 Read triaxial vibration amplitude Data field (0byte) data No data field command Read acceleration, vibration Data field (0byte) frequency, vibration speed, No data field command Vibration amplitude, temperature data Blue is X, Y, Z acceleration data in sequence, the unit is g, the data analysis is consistent with the 04H command analysis method Green is X, Y, Z frequency data in sequence, the unit is Hz, the data analysis method is consistent...

 Open the catalog to page 10
Rion Vibration Sensor AKG392-11

before the sensor responds to the relative acceleration. Automatic output mode:After the sensor is powered on, it will automatically output X, Y, Z acceleration, and the output frequency is based on the set value. If high frequency output is required, please set the baud rate to 115200. (This function can be memory when power off) The default address of the sensor is 00, 1. If multiple sensors are connected to a group of buses at the same time, for example RS485: each sensor needs to be set to a different address to achieve separate control and response acceleration. 2. If the new address is...

 Open the catalog to page 11
Rion Vibration Sensor AKG392-12

Data field (BYTE) The number in the data field indicates the result of the sensor response AKG392T_V210708A Setting instructions and procedures All setting operations are not saved when the power is turned off. The setting is effective imm ediately once comand sent. If you need to save setting command after power off, you need to issue a save command. The operation is:Issue the setting command -> return success, the se tting takes effect -> issue the save command -> return success, the setting is saved. MODBUS uses RTU mode, ‘big-Endian’ represents addresses and data items, adopts CRC16 check...

 Open the catalog to page 12
Rion Vibration Sensor AKG392-15

Note: 0012H is the register address, which controls the baud rate of the sensor. In the above example, the baud rate of the sensor is set to 19200, and the last two bytes are the CRC checksum. 7.Set the parity bit of the sensor serial port: (factory default is even parity) Note: 0013H is the register address, this register controls the sensor output mode. In the

 Open the catalog to page 15
Rion Vibration Sensor AKG392-16

above example, the output rate of the sensor is set to 10HZ, the last two bytes are the CRC checksum, and the automatic output is three-axis acceleration data. 9.Set sensor auto-output data command : Note: 0000H is the register address, which controls the sensor to automatically output data items. In the above example, the output item of the read sensor is 9111H, and the last two bytes are the CRC checksum.

 Open the catalog to page 16

All SHENZHEN RION TECHNOLOGY CO.,LTD catalogs and technical brochures

  1. RION WCA300A

    3  Pages

  2. RION PSI-25M

    1  Page

  3. SDA116T/SDA126T

    16  Pages

  4. HDA437T/HDA437

    25  Pages

  5. HDA436T

    25  Pages

  6. HDA436T-CANOpen

    28  Pages

  7. ACA816T/ACA826T

    17  Pages

Archived catalogs

*Prices are pre-tax. They exclude delivery charges and customs duties and do not include additional charges for installation or activation options. Prices are indicative only and may vary by country, with changes to the cost of raw materials and exchange rates.
About DirectIndustry
DirectIndustry is a marketplace that offers B2B players a complete experience, from product sourcing to purchase. DirectIndustry is an entity of VirtualExpo Group.