Overview
The SDA118T/SDA128T is an industrial-grade inclinometer designed for high-precision measurement of object dynamics with a current output of 4-20mA. It is capable of measuring biaxial inclination and transmitting data over long distances up to 2000 meters. The device is suitable for harsh environments, featuring high anti-vibration performance and strong anti-interference capabilities.

Specifications
- Measurement Range: ±1 to ±90°
- Power Supply: DC 9-36V
- Working Temperature: -40 to +85°C
- Resolution: 0.01°
- Anti-Vibration: >2000g
- Size: 72.6×42×23mm (customizable)
- Protection: IP67

Applications
The inclinometer is used in various applications including rail-mobile monitoring, satellite communications, radar detection, underground drilling, oil-drilling equipment, and ship navigation posture measurement.

Technical Data
- Measure Resolution: 0.01° to 0.05°
- Accuracy at 25°C: 0.03° to 0.1°
- Long-term Stability: 0.05°
- Response Time: 0.02s
- EMC Compliance: EN61000 and GBT17626
- MTBF: ≥98000 hours

Electronic Characteristics
- Supply Voltage: 9-36V
- Working Current: 50mA
- Output Load Resistance: 400-1000Ω
- Operating Temperature: -40 to +85°C
- Storage Temperature: -55 to +125°C

Installation
Proper installation is crucial to avoid measurement errors. The sensor must be mounted parallel to the measured surface, and the axes should be aligned to prevent angular discrepancies.

Ordering Information
Example: SDA128T-10-A1 indicates a standard shell sealed, dual-axis, horizontal installation with a ±10° measurement range and 4-20mA output interface.

Mechanical Parameters
- Connectors: 1m lead cable
- Material: Aluminum alloy
- Installation: 3*M4 screws

Working Principle
The inclinometer uses capacitive micro pendulum technology to measure inclination based on Earth's gravity, converting changes in capacitance to inclination angles.
See more

Catalog excerpts

Rion inclinometer SDA118T-1

SDA118T/SDA128T CURRENT OUTPUT INCLINOMETER CURRENT OUTPUT INCLINOMETER

 Open the catalog to page 1
Rion inclinometer SDA118T-2

SDA118T/SDA128T CURRENT OUTPUT INCLINOMETER ○ CE certification number :ATSZAHE190625019 ○ China National Intellectual Property Appearance Patent (Patent No.: ZL 201830753149.6) ○ Revision time:2024-08-07 Note: Product functions, parameters, appearance, etc. will be adjusted with technical upgrades. Please contact our pre-sales business for confirmation when purchasing. Disclaimer This product is developed exclusively for commercial applications and is prohibited from being used for illegal purposes, such as military activities, research related to nuclear, chemical, or biological weapons, or...

 Open the catalog to page 2
Rion inclinometer SDA118T-3

SDA118T/SDA128T CURRENT OUTPUT INCLINOMETER ▶ DESCRIPTION SDA118T/SDA128T is an industrial-grade current output inclinometer with high anti-vibration performance to ensure high-precision measurement of object dynamics; standard current 4 ~ 20mA output, while outputting the inclination of the biaxial direction, can be transmitted over long distances up to 2000 meters. The attitude parameters (roll and pitch) of the moving carrier can be measured. The output signal has strong anti-interference and is professionally applied to construction machinery equipment working in harsh environments. The product...

 Open the catalog to page 3
Rion inclinometer SDA118T-4

SDA118T/SDA128T CURRENT OUTPUT INCLINOMETER ▶ APPLICATION ★ Rail-mobile monitoring ★ Satellite communications vehicle posture detection ★ Radar detection of vehicle platform ★ Underground drill posture navigation ★ Gun Barrel angle measurement in early shooting ★ Shield pipe jacking application ★ Geological equipment inclined monitoring ★ Ship navigation posture measurement ★ Based on the angle direction measurement ★ Tilt angle measurement of High-altitude construction machinery Measure range Measure axis Zero output Measure Resolution Accuracy Long term stability Zero Temp coefficient Sensitivity...

 Open the catalog to page 4
Rion inclinometer SDA118T-5

SDA118T/SDA128T CURRENT OUTPUT INCLINOMETER ▶ ELECTRONIC CHARACTERISTICS Parameters Supply voltage Working current Output load Operating temperature storage temperature WORDS EXPLANATION Resolution: The sensor can detect and distinguish the smallest change value of measured within the measurement range. Measure Accuracy: The combined deviation of the sensor's linearity, repeatability, hysteresis, zero offset, and horizontal axis deviation on normal temperature conditions. Long-term stability: The deviation between the maximum and minimum values of the sensor after a long times work on normal...

 Open the catalog to page 5
Rion inclinometer SDA118T-6

SDA118T/SDA128T CURRENT OUTPUT INCLINOMETER ▶ WORKING PRINCIPLE The core control unit adopt the import,through the principle of capacitive micro pendulum and earth gravity,when the the inclination unit is tilted,the Earth's gravity of corresponding pendulum will produce a component of gravity,corresponding electric capacity will change,by enlarge the amount of electric capacity/filtering and conversion then get the inclination. ▶ CALCULATION FORMULA FOR ANGLE OUTPUT Angle = (output current - zero position current)÷angle sensitivity Angle sensitivity = output current range ÷ angle measurement...

 Open the catalog to page 6
Rion inclinometer SDA118T-7

SDA118T/SDA128T CURRENT OUTPUT INCLINOMETER Cable color and function Cable color and function BLACK GND Power Negative X-axis output Y-axis output Power Positive Power Negative X-axis output X-axis output

 Open the catalog to page 7
Rion inclinometer SDA118T-8

SDA118T/SDA128T CURRENT OUTPUT INCLINOMETER ▶SIZE MODULE SIZE Shell size: L46×W35.5×H12.5mm Installation size: L37×W29mm ounting screws: 4M3 screws SHELL SIZE Shell size: L72.6×W42×H23mm Installation size: L63.5×W34.5×H4mm ounting screws: 3M4 screws

 Open the catalog to page 8
Rion inclinometer SDA118T-9

SDA118T/SDA128T CURRENT OUTPUT INCLINOMETER ▶ INSTALLATION During installation, keep the sensor mounting surface parallel to the measured surface, and avoid the influence of motion and acceleration on the sensor as possible. Please confirm the installation option with sales before ordering. Six installation options as the diagram below:

 Open the catalog to page 9
Rion inclinometer SDA118T-10

SDA118T/SDA128T CURRENT OUTPUT INCLINOMETER ▶ PRODUCTION INSTALLATION NOTES Please according to the correct method to install inclinometer, incorrect installation will create measurement errors, with particular attention to the "surface", "line":: 1)The Sensor installation surface and the measured surface must be fixed closely, stability,if the install surface unflat, may be created measuring angle error of sensor . 2) The sensor axis and the measured axis must be parallel ,and two axis try not to appear angle.

 Open the catalog to page 10

All SHENZHEN RION TECHNOLOGY CO.,LTD catalogs and technical brochures

  1. RION WCA300A

    3  Pages

  2. RION PSI-25M

    1  Page

  3. SDA116T/SDA126T

    16  Pages

  4. HDA437T/HDA437

    25  Pages

  5. HDA436T

    25  Pages

  6. HDA436T-CANOpen

    28  Pages

  7. ACA816T/ACA826T

    17  Pages

Archived catalogs

*Prices are pre-tax. They exclude delivery charges and customs duties and do not include additional charges for installation or activation options. Prices are indicative only and may vary by country, with changes to the cost of raw materials and exchange rates.
About DirectIndustry
DirectIndustry is a marketplace that offers B2B players a complete experience, from product sourcing to purchase. DirectIndustry is an entity of VirtualExpo Group.