SCA118T/SCA128T CURRENT TYPE INCLINOMETER Appearance Patent No.:ZL 201830752892.X CE certification: AT011611742E FCC certification: AT011611742E RoSH certification: 18300RC20410801 CURRENT TYPE SINGLE/DUAL AXIS INCLINOMETER Technical Manual
Open the catalog to page 1SCA118T/SCA128T CURRENT TYPE INCLINOMETER ○ CE certification number: AT011611742E ○ FCC certification number: AT011611742E ○ RoHS certification number: 18300RC20410801 ○ China National Intellectual Property Appearance Patent (Patent No.: ZL 201830752892.X) ○ Revision time:2024-08-07 ○ Product functions, parameters, appearance, etc. will be adjusted with technology upgrades, please contact the company's pre-sales business to confirm when buying. Disclaimer This product is developed exclusively for commercial applications and is prohibited from being used for illegal purposes, such as military...
Open the catalog to page 2SCA118T/SCA128T CURRENT TYPE INCLINOMETER ▶ INTRODUCTION SCA118T/SCA128T is a standard industrial output type single/dual axis inclinometer with a standard current output of 4-20mA, which can transmit up to 2000 meters over long distances. The output signal has strong anti-interference and is professionally applied to construction machinery equipment working in harsh environments. The product is produced using the latest MEMS sensor production process, and the temperature error and nonlinear error are accurately compensated and corrected. The highest accuracy in a small range can reach 0.02 °...
Open the catalog to page 3SCA118T/SCA128T CURRENT TYPE INCLINOMETER Measure range Measure axis Zero output Resolution Measure accuracy Long term.stability Zero Temp.coefficient Sensitivity temp-coeffi Power-on start time Response frequency EMC MTBF Insulation Resistance Impact resistance 20Hz According to EN61000 and GBT17626c ≥98000 hours/times ≥100 MΩ 100g@11ms、3 Axis Direction (Half Sinusoid) Anti-vibration Protection grade Cables Weight 10grms、10~1000Hz IP67 Standard as 1-meter length, wear-resistant, oil-proof, wide temperature, shielded cable 4 * 0.4mm2 ≤220g (including 1 meter cable) ▶ ELECTRICAL PARAMETERS PARAMETERS...
Open the catalog to page 4SCA118T/SCA128T CURRENT TYPE INCLINOMETER KEY WORDS Resolution: It refers to the smallest change value that the sensor can detect and distinguish in the measurement range. Measure accuracy: Refers to the combined error of linearity, repeatability, hysteresis, zero deviation, and horizontal axis error of the sensor under normal temperature conditions. Long-term stability: refers to the deviation between the maximum value and the minimum value of the sensor under normal temperature conditions after a year of long-term work. Response time: It refers to the time required for the sensor output to...
Open the catalog to page 5SCA118T/SCA128T CURRENT TYPE INCLINOMETER ▶ WORKING PRINCIPLE Adopt imported core control unit and apply the principle of capacitive micro-pendulum. Using the principle of earth's gravity, when the tilting unit tilts, the earth's gravity will produce a gravitational component on the corresponding pendulum, and the corresponding electric capacity will change. By amplifying and filtering the electric capacity, the inclination angle is obtained after conversion. ▶ TYPICAL PERFORMANCE CHART 1: Input and output characteristics: 2: Temperature characteristic graph: ▶ ANGLE CALCULATION FORMULA Angle...
Open the catalog to page 6SCA118T/SCA128T CURRENT TYPE INCLINOMETER Board wiring definition Line color function Vcc9~36V Power supply Power positive Out X X Axis output current Out Y Y Axis output current ▶ SIZE PCBA BOARD SIZE PCBA board size: L46.5×W35.5×H12.5mm Installation size: L37×W29×H2mm Ounting screws: 4 M3 screws 7 /
Open the catalog to page 7SCA118T/SCA128T CURRENT TYPE INCLINOMETER SHELL SIZE Shell size: L90×W40×H26mm Installation size: L78×W29×H4.5mm ounting screws: 4 M6 screws ▶ INSTALLATION PRECAUTIONS Please install the tilt sensor according to the correct method. Improper installation will cause measurement error. Pay attention to the first "surface" and the second "line": 1) The mounting surface of the sensor and the measured surface must be tight, flat and stable. The unevenness of the mounting surface is easy to cause the angle error of the sensor measurement. 2) The axis of the sensor and the axis to be measured must be...
Open the catalog to page 8SCA118T/SCA128T CURRENT TYPE INCLINOMETER ▶ INSTALLATION DIRECTION During installation, keep the sensor mounting surface parallel to the target surface to be measured, and reduce the impact of dynamics and acceleration on the sensor. This product can be installed horizontally or vertically, please refer to the following diagram for the installation method:
Open the catalog to page 9SCA118T/SCA128T CURRENT TYPE INCLINOMETER
Open the catalog to page 107 Pages
3 Pages
1 Page
10 Pages
16 Pages
11 Pages
9 Pages
11 Pages
16 Pages
10 Pages
21 Pages
2 Pages
2 Pages
10 Pages
10 Pages
2 Pages
2 Pages
12 Pages
10 Pages
16 Pages
11 Pages
9 Pages
8 Pages
10 Pages
9 Pages
16 Pages
11 Pages
8 Pages
11 Pages
17 Pages
25 Pages
14 Pages
25 Pages
25 Pages
28 Pages
17 Pages
9 Pages
9 Pages
11 Pages
11 Pages
12 Pages
39 Pages
37 Pages
6 Pages
15 Pages
6 Pages
17 Pages
9 Pages