SCA110T/SCA120T VOLTAGE TYPE INCLINOMETER Appearance Patent No.:ZL 201830752892.X CE certification: AT011611741E FCC certification: AT011611742E RoSH certification: 18300RC20410801 VOLTAGE TYPE SINGLE/DUAL AXIS INCLINOMETER Technical Manual
Open the catalog to page 1SCA110T/SCA120T VOLTAGE TYPE INCLINOMETER ○ CE certification number: AT011611741E ○ FCC certification number: AT011611742E ○ RoHS certification number: 18300RC20410801 ○ China National Intellectual Property Appearance Patent (Patent No.: ZL 201830752892.X) ○ Revision time:2024-08-06 ○ Product functions, parameters, appearance, etc. will be adjusted with technology upgrades, please contact the company's pre-sales business to confirm when buying. Disclaimer This product is developed exclusively for commercial applications and is prohibited from being used for illegal purposes, such as military...
Open the catalog to page 2SCA110T/SCA120T VOLTAGE TYPE INCLINOMETER ▶ INTRODUCTION SCA110T/SCA120T is one tilt sensor with analog voltage output. Users only need to collect the voltage value of the sensor to calculate the current inclination of the object. The built-in (MEMS) micro-solid pendulum is used to measure the change of the static gravity field and convert it into the change of the inclination angle. The change is output through the voltage (0-5V); it is mainly used to measure the inclination of the object and the horizontal plane. This product adopts the principle of non-contact measurement, can output the current...
Open the catalog to page 3SCA110T/SCA120T VOLTAGE TYPE INCLINOMETER ▶ PARAMETERS SCA110/SCA120T Measure range Sensitivity temp-coeffi Measure axis Zero output Resolution Measure accuracy Power-on start time Response frequency EMC MTBF Insulation Resistance Impact resistance Anti-vibration Protection grade Cables Weight 20Hz According to EN61000 和 GBT17626c ≥98000 hours/times ≥100MΩ 100g@11ms、3 Axis Direction (Half Sinusoid) 10grms、10~1000Hz IP67 Standard as 1-meter length, wear-resistant, oil-proof, wide temperature, shielded cable 4 * 0.4mm2 ≤220g (including 1 meter cable) KEY WORDS: Resolution: It refers to the smallest...
Open the catalog to page 4SCA110T/SCA120T VOLTAGE TYPE INCLINOMETER ▶ELECTRICAL PARAMETERS PARAMETER Power supply Optional Working current Output overload Working temp Store temp. ▶ MECHANICAL PARAMETERS ○ Connectors:1m lead cable(customized) ○ Protection glass:IP67 ○ Enclosure material :Aluminum Oxide ○ Installation :4*M6 screws TD: Horizontal-Down V: Vertical VD: Vertical-Down Output voltage Measure range Installation method Measure axis Shell sealed 1: Single-axis 2: Dual-axis 1: Standara shell sealed 2: bared board,without shell E.g:SCA110T-10-V1:Standara shell sealed / Single axis / Hori
Open the catalog to page 5SCA110T/SCA120T VOLTAGE TYPE INCLINOMETER ▶ WORKING PRINCIPLE Adopt imported core control unit and apply the principle of capacitive micro-pendulum. Using the principle of earth's gravity, when the tilting unit tilts, the earth's gravity will produce a gravitational component on the corresponding pendulum, and the corresponding electric capacity will change. By amplifying and filtering the electric capacity, the inclination angle is obtained after conversion. ▶ ANGLE CALCULATION FORMULA Angle = (output voltage-zero position voltage) ÷ angle sensitivity Angle sensitivity = output voltage range...
Open the catalog to page 6SCA110T/SCA120T VOLTAGE TYPE INCLINOMETER ▶ ELECTRICAL CONNECTION Shell package wiring definition BLACK Power supply Power positive Line color function Board wiring definition Power negative Line color Power supply Power positive
Open the catalog to page 7SCA110T/SCA120T VOLTAGE TYPE INCLINOMETER ▶ SIZE PCBA BOARD SIZE PCBA board size: L46.5×W35.5×H12.5mm Installation size: L37×W29×H2mm Ounting screws: 4 M3 screws SHELL SIZE Shell size: L90×W40×H26mm Installation size: L78×W29×H4.5mm ounting screws: 4 M6 screws
Open the catalog to page 8SCA110T/SCA120T VOLTAGE TYPE INCLINOMETER ▶ INSTALLATION PRECAUTIONS Please install the tilt sensor according to the correct method. Improper installation will cause measurement error. Pay attention to the first "surface" and the second "line": 1) The mounting surface of the sensor and the measured surface must be tight, flat and stable. The unevenness of the mounting surface is easy to cause the angle error of the sensor measurement. 2) The axis of the sensor and the axis to be measured must be parallel, and the angle between the two axes should be avoided as much as possible. ▶ INSTALLATION...
Open the catalog to page 9SCA110T/SCA120T VOLTAGE TYPE INCLINOMETER
Open the catalog to page 107 Pages
3 Pages
1 Page
10 Pages
16 Pages
11 Pages
9 Pages
10 Pages
11 Pages
16 Pages
21 Pages
2 Pages
2 Pages
10 Pages
10 Pages
2 Pages
2 Pages
12 Pages
10 Pages
16 Pages
11 Pages
9 Pages
8 Pages
10 Pages
9 Pages
16 Pages
11 Pages
8 Pages
11 Pages
17 Pages
25 Pages
14 Pages
25 Pages
25 Pages
28 Pages
17 Pages
9 Pages
9 Pages
11 Pages
11 Pages
12 Pages
39 Pages
37 Pages
6 Pages
15 Pages
6 Pages
17 Pages
9 Pages