PRECISION INCLINOMETER
Open the catalog to page 1○ China National Intellectual Property Appearance Patent (Patent No.: ZL 202130363422.6) ○ CE certification: AT18250EC101484 ○ Revision date: 2024-08-06 Note: Product functions, parameters, appearance, etc. will be adjusted as technology upgrades. Please contact our pre-sales before purchasing. Disclaimer This product is developed exclusively for commercial applications and is prohibited from being used for illegal purposes, such as military activities, research related to nuclear, chemical, or biological weapons, or any other actions that violate laws and regulations. It is strictly forbidden...
Open the catalog to page 2▶ INTRODUCTION PCA826T-CAN2.0A/CAN2.0B is a high-performance product developed by Rion Technology specially for the high-precision inclination measurement. Before leaving the factory, all products would have full temperature range calibration and compensation, and a two-week long-term stability test ensures compatibility under different working conditions and maintains the best performance indicators during the long-term test cycle. Built-in filtering algorithm makes the product have lower noise and higher response speed.The output signal CAN2.0A/CAN2.0B is optional. The characteristics of non-contact...
Open the catalog to page 3Measure range Measure axis Resolution Measure accuracy Room temp. Room temp. Zero temp coefficient Sensitivity temp. coefficient Power-on start time Response frequency Output rate Output signal Insulation Resistance Shockproof Anti-vibration Protection grade Cables Weight ≥100 MΩ 100g@11ms、3 Axial Direction (Half Sinusoid) 10grms、10~1000Hz IP67 Standard configuration 1 meter, wear-resistant, wide temperature, shielded cable, mm aviation connector ≤400g (Excluding cable) KEY WORDS Resolution: Refers to the sensor in measuring range to detect and identify the smallest changed value. MAXE: refers...
Open the catalog to page 4▶ ELECTRONIC PARAMETERS PARAMETERS Power supply Other voltage Working current Working temperature Store temperature Output Protocol Measure range Installation Direction ▶ MECHANICAL PARAMETERS ○Connector: Aviation connector ○Protection level: IP67 ○Shell material: aluminum alloy anodized ○Installation: Four M6 screws ▶ WORKING PRINCIPLE Adopt imported core control unit and apply the principle of capacitive micro-pendulum. Using the principle of earth's gravity, when the tilting unit tilts, the earth's gravity will produce a gravitational component on the corresponding pendulum, and the corresponding...
Open the catalog to page 5▶ ELECTRICAL CONNECTIONS CAN wiring definition (7-core wiring definition) PIN1 PIN2 PIN3 Line color DC9~36 function GND CAN_L V Shell size: L82×W70×H42mm Installation size: L71×W56×H8mm Mounting screws: 4 M6 screws
Open the catalog to page 6▶ INSTALLATION PRECAUTION Please install the tilt sensor according to the correct method. Incorrect installation will cause measurement errors. Pay special attention to one "surface" and two "line": 1) The sensor mounting surface and the surface to be measured must be fixed tightly, flat and stable, if installation surface is unevenness, it will cause the angle error. 2) The axis of the sensor and the axis to be measured must be parallel, and there should be no angle between the two axes as possible. ▶ INSTALLATION During installation, keep the sensor mounting surface parallel to the measured...
Open the catalog to page 7▶ RION PRODUCT COMMUNICATION PROTOCOL The CAN2.0 protocol supports either 2.0 A (11-bit ID) or 2.0 B (29-bit ID). 1) The sensor has an angle output after power on, the default output is 10HZ, and the message format is as follows: CAN-ID Temperature data Table 1-2 The message format is as follows: 1st 2nd 3rd 4th 5th CAN-ID byte byte byte byte byte 0x580+Node_ID+1 The angle data of the first four bytes of the X axis is represented by a 24-bit binary number, the upper 8 bits are XH, the middle 8 bits are XM, the lower 8 bits are XL, and the symbol is Xsign. Use the 24-bit binary number to convert...
Open the catalog to page 8PCA826T-CAN2.0A/B PRECISION INCLINOMETER 0x025343 = 152387, when calculating 152387/10000=15.2387°, where Xsign=0x01, the final result is -15.2387° 2) Modify the node number. The valid range of the command word is 1 ~ 0x7E. The default node number is 0x05. Table 1-3 Request message format CAN-ID Table 1-4 Reply message format CAN-ID Note: If the controller sends CAN-ID=0x600+0x05, send data: 40 10 10 00 10 00 00 00 The sensor returns CAN-ID=0x580+0x05 (default), and returns data: 40 10 10 00 10 00 00 00. After power reset, the received frame ID is 0x590 (0x580+0x10), indicating that the frame...
Open the catalog to page 9PCA826T-CAN2.0A/B PRECISION INCLINOMETER Note: 4th byte (Cmd) is 0x00, 0x01. Among them, 0x00 means to cancel the relative zero point, 0x01 means to set the relative zero point, and the operation will take effect once set successful. 5) Set the output rate, the default is 10HZ, and the effective range of the command word is 0~6. Table 1-9 Request message format CAN-ID Table 1-10 Reply message format CAN-ID Note: The value of 4th byte (Cmd) is 0x00~0x06. Among them, 0x00 stands for pause output, 0x01 stands for 5HZ, 0x02 stands for 10HZ, 0x03 stands for 25HZ, 0x04 stands for 35HZ, 0x05 stands...
Open the catalog to page 107 Pages
3 Pages
1 Page
10 Pages
16 Pages
11 Pages
9 Pages
10 Pages
11 Pages
16 Pages
10 Pages
21 Pages
2 Pages
2 Pages
10 Pages
10 Pages
2 Pages
2 Pages
12 Pages
10 Pages
16 Pages
11 Pages
9 Pages
8 Pages
10 Pages
9 Pages
16 Pages
11 Pages
8 Pages
11 Pages
17 Pages
25 Pages
14 Pages
25 Pages
25 Pages
28 Pages
17 Pages
9 Pages
9 Pages
11 Pages
11 Pages
12 Pages
39 Pages
37 Pages
6 Pages
15 Pages
6 Pages
17 Pages
9 Pages