RION/3 axis compass display portable compass heading angle monitor/SDC620
12Pages

{{requestButtons}}

Catalog excerpts

RION/3 axis compass display portable compass heading angle monitor/SDC620 - 1

SDC620B-High Accuracy Digital Display 3D Compass North Finder SPECIFICATIONS Item No.SDC620B DescriptionHigh Accuracy Digital Display 3D Compass North Finder VersionVer.05 Production implementation standard reference ● Enterprise quality system standards: ISO9001: 2008 standard (certification number: 128101) ● Tilt sensor production standards: GB / T 191 SJ 20873-2003 inclinometer general specification of Level ● Gyro accelerometer test standard: QJ 2318-92 Gyro accelerometer test methods ● Software development reference standard: GJB 2786A-2009 military software development General requirements ● Product environmental testing standards: GJB150 ● Electromagnetic anti-interference test standards: GB / T 17626

Open the catalog to page 1
RION/3 axis compass display portable compass heading angle monitor/SDC620 - 2

SDC620B-High Accuracy Digital Display 3D Compass North Finder General Description SDC620B is a new type 3D full-posture compass north finder which launched by our company to the satellite search industry , using USA fluxgate technology and advanced hard iron and soft iron calibration algorithm, to make it still can provide the high accurate heading information in tilt 360 ° status , still can accurately show the direction angle when tilt 360deg to identify the relative heading position . SDC620B belongs handheld digital instrument and can remote transmit the 3D data to a computer, through...

Open the catalog to page 2
RION/3 axis compass display portable compass heading angle monitor/SDC620 - 3

SDC620B-High Accuracy Digital Display 3D Compass North Finder Electrical Characteristics

Open the catalog to page 3
RION/3 axis compass display portable compass heading angle monitor/SDC620 - 4

SDC620B-High Accuracy Digital Display 3D Compass North Finder Ordering information: Item No. Order Description RS232 Serial data output functionStandard with 1.5M cable RS485Serial data output functionStandard with 1.5M cable Standard SDC620B 3D compass north finder / RS232Serial data output function Order Description SDC620C means the instrument not integrated the measuring compass inside, only with display and key functions , must be remote connected with another one supporting compass through a cable for using , only limited to RION compass for supporting . SDC620B Measuring...

Open the catalog to page 4
RION/3 axis compass display portable compass heading angle monitor/SDC620 - 5

SDC620B-High Accuracy Digital Display 3D Compass North Finder Product Functions Description: 1) Charging warning light: The light will flash during charging process ,to stop flashing said charging has been full. 2) Low power warming light: This feature can be available when use the internal battery for power supply ,when the low power warming light flash every 0.5 seconds each time means the internal power is not enough , if the low power warming light continuously flash in the course of working ,that means the internal battery lack of electric, at this time it only can work for 30 minutes...

Open the catalog to page 5
RION/3 axis compass display portable compass heading angle monitor/SDC620 - 6

SDC620B-High Accuracy Digital Display 3D Compass North Finder 4) Heading alarm value setting : press and setting H alarm value A.Press key H for 3 seconds then setting the display area X and Y digital tube off , only the H area with digital tube display , at this time the first digit flash once every 0.5 seconds, then press set H alarm value and you can set the first digit from 0 to 9 for transformation, after selected the desired number ,wait for 3 seconds , then jump to the second digit flashing. After set the fourth digit by the same method as above , and then jump back to the first...

Open the catalog to page 6
RION/3 axis compass display portable compass heading angle monitor/SDC620 - 7

SDC620B-High Accuracy Digital Display 3D Compass North Finder SDC620B Calibration methods: SDC620B Calibration lemmas: 1) The accuracy of testing compass can not reach the requirements; testing 2) compass installation environment have magnetic interference, the interference is fixed, and the interference magnetic field and compass installation will not happen again in distance changes (example: compass to be installed above an iron material, because the iron will have calibrate magnetic interference, at this time then need to rotate and calibrate the iron and compass, and the iron and...

Open the catalog to page 7
RION/3 axis compass display portable compass heading angle monitor/SDC620 - 8

SDC620B-High Accuracy Digital Display 3D Compass North Finder After took the fourth point, H and R are the same, and then increase + P angle value. Refer to the left Pic.B: starting point H = 0 °, R = 0 °, P = +55 ° ,please keep this posture for 2-3 seconds don ’t move, the don’ system will take the fifth point. After took the fifth point, again rotate 90 °horizontally, please keep this posture for 2 to 3 seconds don’t move, the system don’ will take the sixth point. After took the sixth point, again rotate 90 °horizontally, please keep this posture for 2 to 3 seconds don ’t move, the...

Open the catalog to page 8
RION/3 axis compass display portable compass heading angle monitor/SDC620 - 9

SDC620B-High Accuracy Digital Display 3D Compass North Finder move, the system will take the eighteenth point. After took the eighteenth point, again rotate 90°horizontally, alternate the positive Roll value R=+15 ° , please keep this posture for 2 to 3 seconds don't move, the system will take the nineteenth point. After took the nineteenth point, again rotate 90 °horizontally,alternate the negative Roll value R=-15 ° , please keep this posture for 2 to 3 seconds don't move, the system will take the twentieth point. After took the twenty second point, again rotate 90°horizontally, alternate...

Open the catalog to page 9
RION/3 axis compass display portable compass heading angle monitor/SDC620 - 10

SDC620B-High Accuracy Digital Display 3D Compass North Finder Set Addr button Save Data: Save the data, click here data can be synchronized Save angle data, the file is stored by default in the C: ---- COMDATA file Set Zero: Set relative zero, the sensor current angle is 00.00 degrees Cancel Zero: Unset the relative zero, to restore the sensor to the factory absolute zero; Baud Rate: Select the sense baud rate , the factory default is 9600; Set Baud Rate: Set the sensor baud rate, on the right of the selection box to select corresponding baud rate then click SetB.R. button; Auto Output:...

Open the catalog to page 10
RION/3 axis compass display portable compass heading angle monitor/SDC620 - 11

SDC620B-High Accuracy Digital Display 3D Compass North Finder Rion Inclinometer Data format DefinitionRion Compass data format: Definition format 一,Data format Baud rate (9600 , 8 data bits1 stop bitno verification) 二,Angle output format Data length, fixed 0D Sensor address code, default 00 Command word, fixed 84 Roll Angle The format is same as Pitch The last byte is the sum of Pitch angle: The first byte is symbol bit,,00 means prefix) and, if binary, then positive angle,10 means negative angle. take a lower order data The second byte is the integer bit of angle , is compressed to BCD...

Open the catalog to page 11

All SHENZHEN RION TECHNOLOGY CO. catalogs and technical brochures

  1. AH200C MEMS

    18 Pages

  2. RION ACA2000T