HCA526T-CAN open-High Accuracy Digital Dual-axis Inclinometer SPECIFICATIONS Item No.:HCA526T-CAN open Description:High Accuracy Digital Dual-axis Inclinometer Production implementation standard reference ● Enterprise quality system standards: ISO9001: 2008 standard (certification number: 128101) ● Tilt sensor production standards: GB / T 191 SJ 20873-2003 inclinometer general specification of Level ●The Academy of metrology and quality inspection Calibrated in accordance to: JJF1119-2004 Electronic Level calibration Specification ● Software development reference standard: GJB 2786A-2009 military software development General requirements ● Product environmental testing standards: GJB150 ● Electromagnetic anti-interference test standards: GB / T 17626 ● Version:Ver.09

Open the catalog to page 1
RION/2 axis high accuracy CAN2.0 inclinometer transducer/HCA526T - 2

HCA526T-CAN open-High Accuracy Digital Dual-axis Inclinometer General Description HCA526T-CAN open is a high accuracy dual -axis inclinometer launched by RION company, inherit the stability of the SCA series, while the accuracy be effectively improved, and the temperature drift performance with much more excellence , in addition the system with built-in high-precision 16bit A / D differential converter, meanwhile through 5 filtering algorithm, which can measure the angle of sensor output relative to the horizontal tilt and pitch tilt. The output interface RS485, RS232, RS422, TTL, or CAN...

Open the catalog to page 2
RION/2 axis high accuracy CAN2.0 inclinometer transducer/HCA526T - 3

HCA526T-CAN open-High Accuracy Digital Dual-axis InclinometerOrdering information: Technical Data Parameters * This Technical data only list ± 10 °, ± 30 °, ± 60 °, + 90 ° series for reference, other measuring range please refer to the adjacent parameters RION TECHNOLOGY sales@rion-tech.net www.rion-tech.net

Open the catalog to page 3
RION/2 axis high accuracy CAN2.0 inclinometer transducer/HCA526T - 4

HCA526T-CAN open-High Accuracy Digital Dual-axis InclinometerElectronic Characteristics Parameters Keywords: Resolution: Refers to the sensor in measuring range to detect and identify the smallest changed value. Absolute accuracy: Refers to in the normal temperature circumstances,the sensor absolute linearity, repeatability, hysteresis, zero deviation, and transverse error comprehensive error. Long term stability : Refers to the sensors in normal temperature conditions, the deviation between the maximum and minimum values after a year's long time work. Response time: Refers to the sensor in...

Open the catalog to page 4
RION/2 axis high accuracy CAN2.0 inclinometer transducer/HCA526T - 5

HCA526T-CAN open-High Accuracy Digital Dual-axis InclinometerDimension Production installation notes : Please follow the correct way to install tilt sensor, incorrect installation can cause measurement errors, with particular attention to the "surface", "line":: 1) The Sensor mounting surface and the measured surface must be fixed closely, smoothly, stability,if mounting surface uneven likely to cause the sensor to measure the angle error. See Figure Pic.AB 2) The sensor axis and the measured axis must be parallel ,the two axes do not produce the angle as much as possible. See Figure Pic.CD...

Open the catalog to page 5
RION/2 axis high accuracy CAN2.0 inclinometer transducer/HCA526T - 6

HCA526T-CAN open-High Accuracy Digital Dual-axis Inclinometer Line color function Rion products’ communication protocol Communication protocol: 1. SDO message: SDO request, response message include 8 bytes, if not enough, add 0 to make it 8 bytes. Write Object format and content of request and response message showed as table 1-1 and 1-2: Node_ID is CAN communication node number, Index_LSB is dictionary index low byte, Index_MSB is dictionary index high byte, Sub_index is sub-index. 1) BOOTUP It send massage automatically after inclinometer initialization accomplished, length of the message...

Open the catalog to page 6
RION/2 axis high accuracy CAN2.0 inclinometer transducer/HCA526T - 7

HCA526T-CAN open-High Accuracy Digital Dual-axis Inclinometer3):modify node number ( Node_ID=0x01 ~ 0x7F ), defualt node numbe( Node_ID ) is 0x05 CAN-I D Second Third byte byte Table 1-3 SDO request message format RION TECHNOLOGY sales@rion-tech.net www.rion-tech.net

Open the catalog to page 7
RION/2 axis high accuracy CAN2.0 inclinometer transducer/HCA526T - 8

HCA526T-CAN open-High Accuracy Digital Dual-axis Inclinometer 5) time setting of cyclic sending PD0 It send below message periodically after start: sales@ rion-tech.net www.rion-tech.net

Open the catalog to page 8
RION/2 axis high accuracy CAN2.0 inclinometer transducer/HCA526T - 9

HCA526T-CAN open-High Accuracy Digital Dual-axis Inclinometer D0,D1 ,D2,D3 is X axis angle D4,D5,D6,D7 is Y axis angle low bytes at the front, high ones at the behind, then divided by 10000 0~ 0X 0D BB A0 signify :+0~+90 FFFFFFFF~FFF2445F signify:-0~ -90 eg: X: 0X 00 00 35 13=13587/10000=1.3587 Y: 0XFFFFFF1D FFFFFFFF-0XFFFFFF1 D=226/10000 = - 0.0226 degree r^More products information, please refer to the company's Website : www.rion-tech.net RION TECHNOLOGY sales@rion-tech.net www.rion-tech.net

Open the catalog to page 9
RION/2 axis high accuracy CAN2.0 inclinometer transducer/HCA526T - 10

CHINASHENZHENRION TECHNOLOGY CO.,LTD. vMfk ( ) 3F3fe vgtMTfc^iSt