HCA528T dual axes current output angle sensor Medical facilities angle control
7Pages

{{requestButtons}}

Catalog excerpts

HCA528T dual axes current output angle sensor Medical facilities angle control - 1

HCA528T-Production implementation standard reference SPECIFICATIONS Item No.HCA528T Description: High Accuracy Current Type Dual-axis Inclinometer Production implementation standard reference ● Enterprise quality system standards: ISO9001: 2008 standard (certification number: 128101) ● Tilt sensor production standards: GB / T 191 SJ 20873-2003 inclinometer general specification of Level ●The Academy of metrology and quality inspection Calibrated in accordance to: JJF1119-2004 Electronic Level calibration Specification ● Software development reference standard: GJB 2786A-2009 military software development General requirements ● Product environmental testing standards: GJB150 ● Electromagnetic anti-interference test standards: GB / T 17626 ● Version:Ver.09 ● Date:2014.4.17

Open the catalog to page 1
HCA528T dual axes current output angle sensor Medical facilities angle control - 2

HCA528T-Production implementation standard reference General Description HCA528T is a high accuracy dual-axis inclinometer, output adopt the standard industry electronic interface 4 ~ 20mA, can be long-distance transmission of up to 2000 meters. The product uses the latest MEMS high technology for production,internal using high-resolution differential digital-to-analog converter, by the internal MCU system secondary linearity and temperature correction, customers no need to do secondary linearity correction, meanwhile also reduces the error caused by environmental changes on the accuracy of...

Open the catalog to page 2
HCA528T dual axes current output angle sensor Medical facilities angle control - 3

HCA528T-Production implementation standard reference Ordering information: . E.gHCA528T-10-A1Dual-axis /Standard/±10°Measuring range /4-20mA output current Technical Data Parameters Conditions Measuring range Measuring axis Response time Measuring range Zero output accuracy Long term stability Zero temperature coefficient Sensitivity temperature coefficient frequency Electromagnetic compatibility MTBF Resistance Shockproof Protection glass Cables IP67 Standard 1M length、wearproof、wide temperature、 Shielded cables4*0.4mm2 air-plug connector * This Technical data only list ± 10 °, ± 30 °, ±...

Open the catalog to page 3
HCA528T dual axes current output angle sensor Medical facilities angle control - 4

HCA528T-Production implementation standard reference Electronic Characteristics Resolution: Refers to the sensor in measuring range to detect and identify the smallest changed value. Absolute accuracy: Refers to in the normal temperature circumstances,the sensor absolute linearity, repeatability, hysteresis, zero deviation, and transverse error comprehensive error. Long term stability : Refers to the sensors in normal temperature conditions, the deviation between the maximum and minimum values after a year's long time work. Response time: Refers to the sensor in an angle change, the sensor...

Open the catalog to page 4
HCA528T dual axes current output angle sensor Medical facilities angle control - 5

HCA528T-Production implementation standard reference Electrical Connection Angle output computational formula Angle = (Output current—ZERO position current)-*-Angle sensitivity Angle sensitivity= Output current range? Angle measuring range E.g: HCA528T-30-A1 (±30° Measuring range 16mA Output current range ) RION TECHNOLOGY sales® rion-tech.net

Open the catalog to page 5
HCA528T dual axes current output angle sensor Medical facilities angle control - 6

HCA528T-Production implementation standard reference Measuring Directions&Fix_ The installation must guarantee the product bottom is parallel to measured face, and reduce the influence of dynamic and acceleration to the sensor. This product can be installed horizontally or mounted vertically (mounted vertically selection is only applicable to the single axis), for installation please refer to Production installation notes : Please follow the correct way to install tilt sensor, incorrect installation can cause measurement errors, with particular attention to the "surface", "line":: 1) The...

Open the catalog to page 6
HCA528T dual axes current output angle sensor Medical facilities angle control - 7

CHINA SHENZHEN RION TECHNOLOGY CO.,LTD.

Open the catalog to page 7

All SHENZHEN RION TECHNOLOGY CO. catalogs and technical brochures

  1. AH200C MEMS

    18 Pages

  2. RION ACA2000T

    11 Pages